Skip to main content
Log in

Untersuchungen mit einer Apparatur zur Röntgenfluorescenzspektralanalyse im Mikroma\stab

II. Bestimmung kleiner Gehalte

  • Originalabhandlungen
  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

Investigations were carried out in order to determine low concentrations of yttrium and neodymium in mixed oxides of rare earths using the internal standards technique with a special x-ray fluorescence equipment, which consists of a spectrometer of advantageous resolution combined with a x-ray tube which permits a strong fluorescence excitation of a few milligrams of substance within the tube. It was shown that it is not necessary to measure the background. The intensity ratios of the total intensities yield linear calibration curves within the concentration range from 0.1 to 1% of oxide. The detection limit is 0.1% for the oxides of yttrium and neodymium.

Zusammenfassung

Mit einer Apparatur zur Röntgenfluorescenzspektralanalyse, bei der ein gut auflösendes Spektrometer mit einer Röhre kombiniert ist, die eine Fluorescenzanregung weniger Milligramm Substanz in der Röhre gestattet, wurden mit der Methode des inneren Standards kleine Gehalte an Yttrium und Neodym in oxidischen Mischungen Seltener Erden bestimmt. Es konnte gezeigt werden, da\ es nicht notwendig ist, die UntergrundintensitÄt zu bestimmen. Die IntensitÄtsverhÄltnisse der GesamtlinienintensitÄten ergeben für den Konzentrationsbereich von 0,1–1% Oxid lineare Eichkurven. Die Nachweisgrenze betrug sowohl für das Yttriumals auch für das Neodymoxid 0,1%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Kaiser, H., u. H. Specker: diese Z. 149, 46 (1956).

    Google Scholar 

  2. Liebhafsky, H. A., H. G. Pfeiffer, E. H. Winslow, and P. D. Zemany: X-Ray Absorption and Emission in Analytical Chemistry. New York, London: J. Wiley & Sons 1960.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Der Deutschen Forschungsgemeinschaft und dem Fonds der Chemischen Industrie danken wir für die finanzielle Unterstützung dieser Arbeit.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Grothe, K.H. Untersuchungen mit einer Apparatur zur Röntgenfluorescenzspektralanalyse im Mikroma\stab. Z. Anal. Chem. 211, 401–406 (1965). https://doi.org/10.1007/BF00519204

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00519204

Navigation