Advertisement

A new method for determining the blood quantity in the eye in a unit of time

  • G. Cristini
  • R. Meduri
  • G. C. Garbini
  • A. Giovannini
Article

Summary

A new method for semiquantitatively determining the blood flow in the eye, in a unit of time is described.

The principles of rheography with “infinite time constant” are utilized.

After applying a suction cup electrode mechanism, by gradual increases of the vacuum, ocular pressure rises above venous pressure, and without modification of arterial inflow, the venous outflow is blocked; in consequence an increase of blood accumulation in the interior of the eye occurs.

The electrical impedance variation, as a result of the latter, gives the recorded tracing a “slow” rising curve, that maintains the same pulse morphology.

After being analyzed and elaborated on with certain mathematical formulae, this curve makes it possible to calculate the blood flow in the eye in a unit of time.

Statistics on normal patients of various ages are reported.

Keywords

Venous Pressure Electrical Impedance Pressure Rise Normal Patient Mathematical Formula 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Zusammenfassung

Es wird eine neue Methode für die quantitative Bestimmung der in der Zeiteinheit das Auge durchströmenden Blutmenge beschrieben.

Zu diesem Zweck wurden die Prinzipien der Rheographie mit „unendlicher Zeitkonstante“ angewandt.

Nach dem Aufsetzen einer mit Elektroden ausgestatteten Saugschale und allmählicher Vergrößerung des Vakuums wurde der Augendruck so erhöht, daß er den des venösen Blutdrucks überstieg. Damit blockierte man den venösen Abfluß, während der arterielle Zufluß unverändert blieb, was ein Anwachsen der Blutdicke im Inneren des Auges zur Folge hatte.

Die Veränderung der elektrischen Impedanz, als Folge der größeren Blutdicke, war in der graphischen Darstellung von einer „langsam“ ansteigenden Kurve gekennzeichnet. Diese Kurve wurde mittels einer besonderen mathematischen Formel analysiert und ausgewertet und gestattete es, quantitative Daten über die in der Zeiteinheit in das Auge einfließenden Blutmenge zu ermitteln.

Darstellung der ersten Untersuchungen an normalen Augen bei normalen Individuen verschiedener Altersklassen.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Becattini, U., Cangi, G., Della Corte, M.: Modern criteria in the interpretation of rheography. Rif. med. 76, 748–770 (1962)Google Scholar
  2. Bettelheim, H.: Oculorheographie. Albrecht v. Graefes Arch. klin. exp. Ophthal. 183, 1–21 (1971)Google Scholar
  3. Bonyer, F. H., Van den Bergh, J. W., Djerken, M. N. I.: Origin of variations of body impedance occurring during cardiac cycle. Circulation 6, 415–420 (1952)Google Scholar
  4. Coles, D. R., Kidd, B. S. L.: Effect of small degrees of venous distension on the apparent inflow rate of blood to the human calf. Circulat. Res. 19, 223–225 (1957)Google Scholar
  5. Conrad, M. C., Green, H. D.: Evaluation of venous occlusion plethysmography. J. appl. Physiol. 16, 289–292 (1961)Google Scholar
  6. Cristini, G., Fiorenzi, G.: Uveale Bio-Hämo-Fotometrie (eine neue Meßmethode der Uvea-Durchblutung am Lebenden). Klin. Mbl. Augenheilk. 138, 216–226 (1961)Google Scholar
  7. Cristini, G., Garagnani, N.: Prime indagini reografiche in oftalmologia. Atti Congr. Soc. Oft. Ital. 41, 142 (1956)Google Scholar
  8. Edholm, O., Moreira, M., Werner, A.: The effect of a raised venous pressure on venous oxygen content of the forearm. J. Physiol. (Lond.) 125, 57 (1954)Google Scholar
  9. Ersler, G.: Zur Rheookulographie. Klin. Mbl. Augenheilk. 153, 276–278 (1968)Google Scholar
  10. Formel, P. F., Doyle, J. T.: Rationale of venous occlusion plethysmography. Circulat. Res. 5, 354–356 (1957)Google Scholar
  11. Garbini, G. C., Giovannini, A., Meduri, R., Schiavi, L.: Rilievi reografici comparativi oculari e cranio-cerebrali. Boll. Soc. Med. Chir. Modena 73, I, 1–20 (1973)Google Scholar
  12. Garbini, G. C., Posteli, T.: Reografia “a constante di tempo infinita” periferica ed epatosplenica. Arc. Pat. Clin. med. 45, V, 367–386 (1968)Google Scholar
  13. Kedrov, A. A.: Comparative evaluation of determination of pulse pressure and pulse volume as cardiac function test. Klin. Med. (Wien), 7, 27, 24–30 (1949)Google Scholar
  14. Landowne, M., Katz, L. N.: Critique of plethysmographic method of measuring blood flow in extremities of man. Amer. Heart J. 23, 644–675 (1942)Google Scholar
  15. Mouillon, M., Bonnet, J. L., Piquard, J. F.: Recherche d'une méthode de mésure d'irrigation de l'oeil par la technique rheographique à quatre electrodes. Bull. Soc. Ophtal. Fr. 77–85 (1973)Google Scholar
  16. Nyboer, J.: Medical physics, O. Glasser ed., p. 340–341. Chicago: Year Book Pub. 1944Google Scholar
  17. Schlegel, H. H.: Spontane und medicamentös beeinflußte Plethysmogramme der menschlichen Uvea. Ber. dtsch. ophthal. Ges. 62, 153–157 (1959)Google Scholar
  18. Swegmark, G.: Studies on the electrical impedance of the human eye: a preliminary report. Acta Ophthal. (Kbh.) 44, 121–131 (1966)Google Scholar
  19. Van Beunigen, E. G. A., Fischer, F. W.: Die arterielle Minutenvolumenbestimmung des Auges und ihre klinische Bedeutung. Ber. dtsch. ophthal. Ges. 61, 218–227 (1957)Google Scholar
  20. Wilkins, R. W., Bradley, S. E.: Changes in arterial and venous blood pressure and flow distal to a cuff implanted on the human arm. Amer. J. Physiol. 147, 260–269 (1946)Google Scholar

Copyright information

© Springer-Verlag 1975

Authors and Affiliations

  • G. Cristini
    • 1
  • R. Meduri
    • 1
  • G. C. Garbini
    • 1
  • A. Giovannini
    • 1
  1. 1.Clinica Oculistica Università di BolognaItalia

Personalised recommendations