Skip to main content
Log in

A microfluorescent PAS method for the quantitative demonstration of cytoplasmic 1,2-glycols

  • Published:
Histochemistry Aims and scope Submit manuscript

Summary

Fluorescent microspectrophotometry using dichroic mirror vertical epi-illumination of tissue sections stained with the PAS reaction (periodic acid and pararosaniline Schiff reagent) provides a measure of the relative concentration of 1:2 glycols within and between tissue sections. In PAS reacted sections of agarose gel, pararosaniline Schiff fluorescence increases linearly as the concentration of agarose increases (r=0.97, p<0.05). The concentration of glycogen within liver as measured by a phenol-based tissue assay is linearly correlated with pararosaniline Schiff fluorescence of formalin fixed liver sections (r=0.87, p<0.05). These relationships are unaffected by alcina blue or hematoxylin. Heretofore the amount of color reaction as measured by densitometry at the pararosaniline absorption peak was claimed to be an unreliable indicator of the amount of reactive glycol present in tissue. Our observations indicate that when the concentration of Schiff reagent exceeds an empiric limit relative to available polysaccharides, the Schiff reagent-tissue complex reflects light at the excitation wavelength instead of fluorescing the emission spectra. This can be circumvented by using dilute pararosaniline-Schiff reagent, shortening the staining period, and lowering the temperature of the staining medium.

While routine PAS staining reactions are followed by washing in running water to develop the red color seen with broad spectrum illumination, water development is unnecessary for the dye-tissue complex to fluoresce. The fluorescent emission peak and the maximum excitation peak of both developed and undeveloped pararosaniline-Schiff-reagent-tissue complexes are 645–50 nm and 540–45 nm, respectively. These spectral characteristics are not changed by binding to oxidation products of different glycoproteins or polysaccharides. Intense exposure to room light, but not 100 repetitive short (0.13 s) exposures, causes partial photodecomposition.

Quantitative assessment of cytofluorescence requires definition of the optical system used to measure emission. In the microspectrophotometer employed in this study, dichroic mirrors reflect light with variable efficiency depending on wavelength from the light source to the stage, and variably block light reflected or emitted from the specimen, serving as crude barrier filters. These dichroic mirror characteristics are influenced by the exact nature of the optical coating on the surface of each individual mirror. Since the optical coating of similar mirrors may vary, the properties of individual mirrors must be considered in the interpretation of spectral data and in determining the proper optical conditions for quantification of cytofluorescence.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Böhm, N., Sprenger, E.: Fluorescence cytophotometry: A Valuable method for the quantitative determination of nuclear Feulgen-DNA. Histochemistry 16, 100–118 (1968)

    Google Scholar 

  • Cassie, R.M.: Some uses of probability paper in the analysis of size frequency distributions. Aust. J. Marine and Fresh Water. Res. 5, 513–522 (1954)

    Google Scholar 

  • Combs, J.W.: An automatic microspectrophotometric system for rapid quantitative cytofluorimetry and reflectance autoradiography. Microscope 21, 11–21 (1973)

    Google Scholar 

  • Dahlqvist, A., Olsson, I., Norden, A.: The periodate Schiff reaction specificity, kinetics and reaction products with pure substances. Histochemistry 40, 423–480 (1974)

    Google Scholar 

  • Fujita, S.: DNA cytofluorometry on large and small cell nuclei stained with pararosaniline Feulgen. Histochemie 36, 193–199 (1973)

    Google Scholar 

  • Fujita, S., Fukuda, M.: Irradiation of specimens by excitation light before and after staining with pararosaniline Feulgen. A new method to reduce non-specific fluorescence in cytophotometry. Histochemistry 40, 59–67 (1974)

    Google Scholar 

  • Fujita, S., Fukuda, M., Kitamura, T., Yoshida, S.: Two-wave-length scanning method in Feulgen cytophotometry. Acta histochem. cytochem. 5, 146–152 (1972)

    Google Scholar 

  • Garcia, A.M., Iorio, R.: Potential sources of error in two wavelength cytophotometry and a one wavelength, two area method in cytophotometry for cells in smears or prints. In: Introduction to quantitative cytochemistry (ed. by G.L. Wied), pp. 215–245. New York: Academic Press 1966

    Google Scholar 

  • Gurr, E.: Encyclopedia of microscopic stains, pp. 204–205. Baltimore: Williams & Wilkins 1961

    Google Scholar 

  • Hale, A.J.: Feulgen microspectrophotometry and its correlation with other cytochemical methods. In: Introduction to quantitative cytochemistry, (ed. by G.L. Wied), pp. 83–99. New York: Academic Press 1966

    Google Scholar 

  • Harding, J.P.: The use of probability paper for the graphical analysis of polymodal frequency distributions. J. Mar. Biol. Assoc. (U.K.) 28, 141–153 (1949)

    Google Scholar 

  • Jenkins, F.A., White, H.E.: Fundamentals of optics, p. 455. New York: McGraw-Hill 1957

    Google Scholar 

  • Kasten, F.: Schiff-type reagents in cytochemistry. Histochemie 1, 466–509 (1959)

    Google Scholar 

  • Kasten, F.H., Kieffer, G., Sandritter, W.: Bleaching of Feulgen stained nuclei and alteration of absorption curve after continuous exposure to visible light in a cytophotometer. J. Histochem. 10, 547–555 (1962)

    Google Scholar 

  • Katyar, S.S., Sinha, S.K.: Kinetics of the reaction of pararosaniline with hydroxyl groups. Ind. J. Chem. 13, 116–119 (1975)

    Google Scholar 

  • Leblond, C.P., Glegg, R.E., Eidinger, D.: Presence of carbohydrates with free 1,2-glycol groups in sites stained with periodic acid Schiff technique. J. Histochem. Cytochem. 5, 445–460 (1957)

    Google Scholar 

  • Mayer, R.T., Novacek, W.M.: A direct recording microspectrofluorometer. J. Microscopy 102, 165–177 (1974)

    Google Scholar 

  • McManus, J.F.A.: Histological and histochemical use of periodic acid. Stain Techn. 23, 99–108 (1948)

    Google Scholar 

  • Mendelsohn, M.L.: Absorption cytophotometry comparative methodology of heterogeneous objects and the two wavelength method. In: Introduction to quantitative cytochemistry (ed. by G.L. Wied), pp. 201–214. New York: Academic Press 1966

    Google Scholar 

  • Meyers, F.H., Jawetz, E., Goldfien, A.: Review of Medical pharmacology. Los Altos: Lange Medical Publications 1974

    Google Scholar 

  • Montgomery, R.: Determination of glycogen. Arch. Biochem. Biophys. 67, 378–386 (1957)

    Google Scholar 

  • Pearse, A.G.E.: Histochemistry, Vol. 1. Boston: Little-Brown Company 1968

    Google Scholar 

  • Ploem, J.S.: Die Möglichkeit der Auflichtfluorescenzmethoden bei Untersuchungen von Zellen in Durchströmungskammern und Heightonrohren. In: Immunohistochemie. Verh. d. Ges. f. Histochemie, 10 Sympos. 1965 (H.V. Mayersbachjed). Acta histochem. (Jena), Suppl. 7, 339–343 (1967a)

  • Ploem, J.S.: The use of a vertical illuminator with interchangeable dichroic mirrors in fluorescent microscopy with incident light. Z. wiss. Mikr. 68, 129–142 (1967b)

    Google Scholar 

  • Ploem, J.S., deSterke, J.A., Bonnet, J., Wasmud, H.: A microspectrofluorometer with epi-illumination operated under computer control. J. Histochem. Cytochem. 22, 668–677 (1974)

    Google Scholar 

  • Prenna, G., Leiva, S., Mazziui, G.: Quantitative DNA-fluorimetry by the conventional Feulgen reaction. In: Histochemistry and cytochemistry, ed. by T. Takeuchi, K. Ogawa, S. Fujita, pp. 201–202. Kyoto: Nakanishi Publ. Co. 1972

    Google Scholar 

  • Puchtler, H., Meloan, S.N., Brewton, B.R.: The binding of Schiff's reagent in the PAS reaction: Effects of molecular configuration. Histochemistry 40, 291–299 (1974)

    Google Scholar 

  • Rost, F.W.D., Pearse, A.G.E.: An improved microspectrofluorometer with automatic digital data logging: Construction and operation. J. Microscopy 94 (II), 93–105 (1971)

    Google Scholar 

  • Ruch, F.: Determination of DNA content by microfluorometry. In: Introduction to quantitative cytochemistry (ed. by G.L. Wied), pp. 281–294. New York: Academic Press 1966

    Google Scholar 

  • Van Duijn, P.: A histochemical specific thionin-SO2 reagent and its use in a biocolormethod for deoxyribonucleic acid and periodic acid Schiff positive substances. J. Histochem. Cytochem. 4, 55–63 (1956)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This investigation was supported by National Institutes of Health Research Service Award IF32 NS 517701 PTHA from the National Institute of Neurological and Communicative Disorders and Stroke and the National Cancer Institute Grant R01 CA 17341

Rights and permissions

Reprints and permissions

About this article

Cite this article

Changaris, D.G., Combs, J. & Severs, W.B. A microfluorescent PAS method for the quantitative demonstration of cytoplasmic 1,2-glycols. Histochemistry 52, 1–15 (1977). https://doi.org/10.1007/BF00495809

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00495809

Keywords

Navigation