Advertisement

Fresenius' Zeitschrift für analytische Chemie

, Volume 312, Issue 7, pp 611–612 | Cite as

Volumetric determination of uranium in a mixture of uranium and plutonium employing Fe(III) as titrant

  • V. K. Manchanda
  • G. A. Rama Rao
  • P. R. Natarajan
Original Papers

Summary

A method for the determination of U in the presence of Pu based on the reduction of U to U(IV) and Pu to Pu(III) by zinc amalgam followed by oxidimetry of U(IV) has been developed. Fe(III) perchlorate was chosen as the most suitable titrant for the selective oxidation of U(IV) as conventional oxidising titrants fail in the presence of Pu(III). The potentiometric titration of U(IV) with Fe(III) is known to be slow. This problem, however, has been overcome by selecting a suitable buffer medium and complexing agent to alter the potentials of the Fe(III)/Fe(II) and U(VI)/U(IV) systems in the favourable direction. Results of the titration of U(IV) with Fe(III) at pH 2 in the presence of ferrozine as complexing agent for Fe(II) are summarized. R.S.D. obtained for twenty determinations of 3–5 mg of U was 0.3 % in the presence of 1–4 mg of Pu.

Keywords

Oxidation Zinc Inorganic Chemistry Titration Uranium 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Volumetrische Bestimmung von Uran in einem U/Pu-Gemisch mit Hilfe von Fe(III)

Zusammenfassung

Das Verfahren beruht auf der Reduktion von U zu U(IV) und Pu zu Pu(III) mit Hilfe von Zinkamalgam und anschließender Titration mit Fe(III)-perchlorat. Dieses Reagens hat sich für die selektive Oxidation des U(IV) am besten bewährt, da andere Oxidationsmittel in Gegenwart von Pu(III) versagen. Die Endpunktsindikation erfolgt potentiometrisch, wobei die an sich langsame Einstellung des Endpunktes dadurch beschleunigt wird, daß durch Zusatz eines geeigneten Puffers und eines Komplexierungsmittels (Ferrozin) für Fe(II) die Redoxpotentiale von Fe(III)/Fe(II) und U(VI)/U(IV) entsprechend verschoben werden. Die relative Standardabweichung für die Bestimmung von 3–5 mg U in Gegenwart von 1–4 mg Pu liegt bei 0,3%.

References

  1. 1.
    Eberle AR, Lerner MW, Goldbeck CG, Rodden CJ (1970) NBL-252Google Scholar
  2. 2.
    Hseih JY, Jaselskis B (1979) Talanta 26:141Google Scholar
  3. 3.
    Hubert S, Hussonnois M, Guillaumont R (1975) J Inorg Nucl Chem 37:1255Google Scholar
  4. 4.
    Nair GM, Chander K, Joshi JK (1982) Radiochim Acta (in press)Google Scholar
  5. 5.
    Rao CL, Nair GM, Singh NP, Ramaniah MV, Srinivasan N (1971) Fresenius Z Anal Chem 254:126Google Scholar
  6. 6.
    Riggs WM (1972) Anal Chem 44:390Google Scholar
  7. 7.
    Stookey L (1970) Anal Chem 42:779Google Scholar
  8. 8.
    Vydra F, Pribil R (1962) Talanta 9:1009Google Scholar
  9. 9.
    Woods R, Kolthoff IM, Meehan EJ (1963) J Am Chem Soc 85:2385Google Scholar

Copyright information

© Springer-Verlag 1982

Authors and Affiliations

  • V. K. Manchanda
    • 1
  • G. A. Rama Rao
    • 1
  • P. R. Natarajan
    • 1
  1. 1.Radiochemistry DivisionBhabha Atomic Research CentreTrombay, BombayIndia

Personalised recommendations