Skip to main content
Log in

Direktmessung von Quecksilber in biologischen Feststoffproben mittels Zeeman-Atomabsorption (ZAAS) im Graphitrohrofen

Direct measurement of mercury in solid biological samples by Zeeman atomic absorption spectrometry (ZAAS) in the graphite furnace

  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

The possibility of direct Hg measurement in biological materials was tested using a Zeeman atomic absorption spectrophotometer (ZAAS). It was found that the high background compensation of ZAAS allows the separation of the specific Hg absorption from the unspecific smoke absorption. Conditions are specified for direct Hg determination in samples with a Hg content of more than 0.2 μg/g (ppm) in the dry matter. The described procedure is therefore applicable to biological materials with Hg contents within this range. These include for example waste composts, sewage sludge, mushrooms and earthworms. Up to 1 or 2 mg samples in the graphite boat can be directly atomized in the graphite furnace at 1,700° C without a preparatory ashing step. For calibration, sewage sludge material with a certificated Hg content of 3 μg/g in the dry matter is used as a reference standard.

Zusammenfassung

Die Möglichkeit der Direktbestimmung von Hg in biologischen Materialien wurde im Graphitrohrofen eines Zeeman-Atomabsorptionsspektralphotometers (ZAAS) erprobt. Die hohe Untergrundkompensation des ZAAS ermöglicht die Trennung der spezifischen Hg-Absorption von dem unspezifischen Rauchsignal. Es werden die Bedingungen beschrieben, unter welchen die Direktmessungen von Hg in Proben mit mehr als 0,2 μg/g i.TS. durchführbar sind. Diese Größenordnung ist bei biologischen Proben wie Müllkomposten, Klärschlämmen, Pilzen und Regenwürmern zu finden. Ohne vorangehenden chemischen Aufschluß können bis zu 1 oder 2 mg der Probe im Graphitschiffchen direkt ohne Veraschungsstufe im Graphitrohrofen bei 1700° C atomisiert werden. Zur Kalibrierung wird ein Klärschlammreferenzmaterial mit einem zertifizierten Gehalt an Hg von 3 μg/g i. TS. eingesetzt.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Massmann H, El Gohary Z (1981) In: Koch KH, Massmann H (eds) 13. Spektrometertagung. Walter de Gruyter, Berlin New York

    Google Scholar 

  2. Wirz P, Kurfürst U, Grobecker K-H (1980) Labor-Praxis 5:16–23

    Google Scholar 

  3. Völlkopf U, Schulze H (1983) Labor-Praxis 7:1–11

    Google Scholar 

  4. Rosopolo A, Kreuzer W (1981) Postervortrag 93. VDLUFA-Kongress Trier

  5. Steubing L, Grobecker K-H, Kurfürst U (1980) Staub Reinh-Luft 40:537–540

    Google Scholar 

  6. Kurfürst U, Rues B (1981) Fresenius Z Anal Chem 308: 1–6

    Google Scholar 

  7. Schulz W (1982) CLB Chem Lab Betr 33:Heft 11

  8. Dorner NG (1982) GIT Fachz Lab 26:750–754

    Google Scholar 

  9. Matthes W, Flucht R, Stoeppler M (1978) Fresenius Z Anal Chem 291:20–26

    Google Scholar 

  10. Anderson PJ (1984) At Spectrosc 5:101–107

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Vorgetragen anläßlich des Kolloquiums „Stand und Perspektive der Feststoffanalyse mit AAS“, Wetzlar, 8.–10. 10. 1984

Rights and permissions

Reprints and permissions

About this article

Cite this article

Fleckenstein, J. Direktmessung von Quecksilber in biologischen Feststoffproben mittels Zeeman-Atomabsorption (ZAAS) im Graphitrohrofen. Z. Anal. Chem. 322, 704–707 (1985). https://doi.org/10.1007/BF00490544

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00490544

Navigation