Skip to main content
Log in

Einige Probleme der Chrombestimmung im biologischen Material bei der Erfassung und Auswertung des Meßsignals mit der ETA-AAS

Problems of chromium determination in biological material with acquisition and evaluation of the measuring signal by ETA-AAS

  • Originalarbeiten
  • Spurenelement-analyse
  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

An analysis of external parameters during the acquisition of the chromium measuring signal in biological material by ETA-AAS is presented. Some recommendations are given how to increase the reliability of the chromium values in biological material: By carbide formation in untreated graphite tubes the measuring signal is progressively decreased. Therefore, pyrolytically coated graphite tubes should be used. The reduction of the inert gas stream during electrothermical treatment of the biological sample might cause a too high, unspecific signal. This could also lead to false, increased chromium values.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Buess H (1961) In: Baader EW (ed) Handbuch der gesamten Arbeitsmedizin, Bd. II, Teil 1. Urban und Schwarzenberg, Berlin München Wien, S 276–295

    Google Scholar 

  2. Burrows D (1983) Chromium: metabolism and toxicity. CRC Press Inc, Boca Raton, Florida

    Google Scholar 

  3. Dungs K, Fleischhauer H, Neidhart E (1985) Fresenius Z Anal Chem 322:280–289

    Google Scholar 

  4. Grafflage B, Buttgereit G, Kübler W, Mertens H-M (1974) Z Klin Chem Klin Biochem 12:287–293

    Google Scholar 

  5. Hertel RF (1982) Staub Reinhalt Luft 42:135–137

    Google Scholar 

  6. Lewalter J, Korallus U, Harzdorf C, Weidemann H (1985) Int Arch Occup Environ Health 55:305–318

    Google Scholar 

  7. Ed DFG (1986) Maximale Arbeitsplatzkonzentrationen und biologische Arbeitsstofftoleranzwerte, Mitteilung XXII. Verlag Chemie, Weinheim, S 84–87

    Google Scholar 

  8. Routh MW (1980) Anal Chem 52:182–185

    Google Scholar 

  9. Samitz MH (1961) Arch Dermatol 84:404–409

    Google Scholar 

  10. Schaller KH, Essing H-G, Valentin H, Schäcke G (1972) Z Klin Chem Klin Biochem 10:434–437

    Google Scholar 

  11. Schwartz K, Mertz W (1957) Arch Biochem Biophys 72:515

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Stipendiat der Carl Duisberg Gesellschaft e.V., Shandong Institut für Umweltschutz, Jinan, V. R. China

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yin, X., Bencze, K. Einige Probleme der Chrombestimmung im biologischen Material bei der Erfassung und Auswertung des Meßsignals mit der ETA-AAS. Z. Anal. Chem. 327, 674–675 (1987). https://doi.org/10.1007/BF00489159

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00489159

Navigation