Summary

The possibilities of ICP (Inductively Coupled Plasma) emission spectroscopy for the quantitative determination of trace elements in bio-medical (tissues, body-fluids) and in environmental samples (plants, soils, sludges) are discussed in alphabetical order of the elements by means of practical examples. In particular, possible matrix influences, physical interferences (overlapping), choice of the device parameters and comparison with other analytical methods are described.

Zusammenfassung

Die Möglichkeiten der ICP (Inductively Coupled Plasma)-Emissionsspektroskopie für die quantitative Bestimmung von Spurenelementen in biologisch-medizinischen Proben (Gewebe, Körperflüssigkeiten) und in Umweltproben (Pflanzen, Böden, KlÄrschlÄmme u.a.) werden in alphabetischer Reihenfolge der Elemente an Hand von praktischen Beispielen aus dem tÄglichen Laborbetrieb diskutiert. Im besonderen wird auch auf mögliche Matrixeinflüsse, physikalische Interferenzen (Linienüberlagerungen), Wahl der optimalen GerÄteparameter und auf den Vergleich mit anderen analytischen Verfahren eingegangen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Greenfield S, McGeachin H Mcd, Chambers FA (1977) ICP Inf Newsl 4:117

    Google Scholar 

  2. Schramel P, Ovcar-Pavlu J (1979) Fresenius Z Anal Chem 298:28–31

    Google Scholar 

  3. Schramel P (1980) Spectrochim Acta 35B:239

    Google Scholar 

  4. Schramel P (1979) Z Lebensm Unters Forsch 169:255

    Google Scholar 

  5. Broekaert JAC (1981) Workshop „Elementanalytik in biologischen Matrices“, 29. 3.–31. 3. 1981, Reisensburg, Bundesrepublik Deutschland

  6. Knapp G, Raptis S, Schreiber B (1981) wie [17], S. 523

    Google Scholar 

  7. Schramel P, Fischer R, Wolf A, Hasse S (1981) ICP Inf Newsl 6:401

    Google Scholar 

  8. Schramel P, Klose B-J (1981) Fresenius Z Anal Chem 307:26–30

    Google Scholar 

  9. Mermet JM, Trassy C (1977) Appl Spectrosc 31:237

    Google Scholar 

  10. Gstrein H, Knapp G, Kaiser G, Tölg G, Schreiber B: in Vorbereitung

  11. Schramel P, Klose B-J (1980) Fresenius Z Anal Chem 302:62–64

    Google Scholar 

  12. Schramel P (1981) wie [17], S. 611

    Google Scholar 

  13. Winge RK, Peterson VS, Fassel VA (1978) Appl Spectrosc 33:206

    Google Scholar 

  14. Massachusetts Institute of Technology Wavelength Tables, Ed (1969) The MIT Press

  15. Parsons ML, Forster A, Anderson D (1980) An Atlas of Spectral Interferences in ICP Spectroscopy, Plenum Press, New York, London

    Google Scholar 

  16. Boumans PWJM (1981) Line Coincidence Table for Inductively Coupled Plasma Emission Spectroscopy, Pergamon Press, Oxford

    Google Scholar 

  17. Proceedings “1st Int. Workshop on Trace Element Analytical Chemistry in Medicine and Biology (1981) BrÄtter P, Schramel P (eds). W de Gruyter, Berlin, New York

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schramel, P., Klose, B.J. & Hasse, S. Die LeistungsfÄhigkeit der ICP-Emissionsspektroskopie zur Bestimmung von Spurenelementen in biologisch-medizinischen und in Umweltproben. Z. Anal. Chem. 310, 209–216 (1982). https://doi.org/10.1007/BF00484034

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00484034

Navigation