Summary
The backscattered electron signal, generated in individual cells, has been used to measure the dry mass of these cells. Absolute mass values were obtained by comparing the backscattered electron signals of cells to the signals of polystyrene-latex spheres of known mass. The technique was carried out in an automated analytical scanning transmission electron microscope and applied to rat blood platelets.
The resulting mass distributions agreed well with the distribution measured with a method that uses the transmitted electron signal by means of densitometric analysis of electrographs. Also the range of masses was in agreement with values deduced from data in the literature.
The fully automated technique has the advantage that it is direct, fast, and that thicker specimens can be measured than is possible using the transmitted electron signal. The method is intended for use in combination with quantitative electron probe X-ray microanalysis and is then able to produce elemental mass fractions of biological specimens at the subcellular level.
Similar content being viewed by others
References
Hagemann P, Reimer L, Burmeister R (1977) Äquidensiten und Massenbestimmung in der Rastertransmissionselektronenmikroskopie. Beitr Elektronenmikrosk Direktabb Oberfl 10:187–194
Hall TA (1971) The microprobe assay of chemical elements. In: Oster G (ed) Physical techniques in biological research, vol 1A, 2nd ed. Academic Press, New York, pp 157–275
Hall TA (1979) Problems of the continuum-normalisation method for the quantitative analysis of sections of soft tissues. In: Lecheune CP, Warner RR (eds) Microbeam analysis in biology. Academic Press, New York, pp 185–208
Linders PWJ (1984) Mass determination based on electron scattering in electron probe X-ray microanalysis of biological thin specimens. PhD Thesis University of Nijmegen, The Netherlands
Linders PWJ, Hagemann P (1983) Mass determination of thin biological specimens using backscattered electrons. Application in quantitative X-ray microanalysis on an automated STEM system. Ultramicroscopy 11:13–20
Linders PWJ, Hagemann P (1984) Quantitative X-ray microanalysis of thin biological specimens using on-line mass determination based on electron back-scattering with correction for the elemental composition. In: Proceedings of the 8th European Congress on Electron Microscopy, Budapest 1984, vol 3, pp 1709–1710
Linders PWJ, Zahniser DJ, Stols ALH, Stadhouders AM (1982a) Improved mass determination of isolated biological objects by transmission electron microscopy and scanning microdensitometry. J Histochem Cytochem 30:637–644
Linders PWJ, Stols ALH, Vorstenbosch RA van de, Stadhouders AM (1982b) Mass determination of thin biological specimens for use in quantitative electron probe X-ray microanalysis. Scanning Electron Microsc 1982 IV:1603–1615
Linders PWJ, Stols ALH, Stadhouders AM (1983) Calibration of transmission electron microscopic mass determination using objects of known mass distribution. J Microsc 130/1:85–92
Linders PWJ, Vorstenbosch RA van de, Smits HTJ, Stols ALH, Stadhouders AM (1984) Absolute quantitative electron microscopy of thin biological specimens by energy-dispersive X-ray microanalysis and densitometric mass determination. Anal Chim Acta 160:57–67
Linders PWJ, Vorstenbosch RA van de, Stadhouders AM (1985) Quantitative electron probe X-ray microanalysis and densitometric mass determination of individual rat blood platelets. J Histochem Cytochem 33:185–190
Niedrig H (1978) Physical background of electron backscattering. Scanning 1:17–34
Prost-Dvojakovic RJ, Le Tobic F, Boulard Ch (1975) Study of platelet volumes and diameters in 11 mammals. In: Ulutin ON (ed) Platelets. Exerpta Medica, Amsterdam, pp 30–36
Stols ALH, Smits HTJ, Stadhouders AM (1986) Modification of a TEM-goniometer specimen holder to enable beam current measurements in a (S) TEM for use in quantitative X-ray microanalysis. J Electron Microsc Techn (Accepted for publication)
Author information
Authors and Affiliations
Additional information
In honour of Prof. van Duijn
Rights and permissions
About this article
Cite this article
Stols, A.L.H., Stadhouders, A.M., Linders, P.W.J. et al. The use of backscattered electrons in analytical electron microscopy for the measurement of the mass of individual rat blood platelets. Histochemistry 84, 379–382 (1986). https://doi.org/10.1007/BF00482966
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00482966