Skip to main content
Log in

Derivativ-Chronopotentiometrie

Aufbau einer elektronischen Meßanordnung und analytische Anwendung

Derivative chronopotentiometry

Electronic measuring device and analytical application

  • Originalabhandlungen
  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

An apparatus for chronopotentiometric measurement using electronic signal-evaluation is described. Digital values of the concentration-dependent transition times (in the range of seconds to milliseconds) are obtained via the second derivative of the potential-time dependence. The time-signals of single components of a multi-component system can be preselected by means of an impulse-selection switch. The process measured can be checked via the potential at which the signal voltage in the 2nd derivative mode changes its sign.

The range of applicability of derivative chronopotentiometry is illustrated by studies on thallium(I) solutions. Empirical transition times are obtained, which may be corrected in an experimental procedure to give values suitable for analytical interpretation.

Zusammenfassung

Es wird der Aufbau einer chronopotentiometrischen Meßanordnung mit elektronischer Signalwertbestimmung beschrieben. Die digitale Erfassung konzentrationsproportionaler Transitionszeiten im Sekunden- bis Millisekunden-Bereich erfolgt über die 2. Ableitung der Potential-Zeit-Abhängigkeiten. Mit einer Impulsauswahlschaltung können bei der Untersuchung von Mehrstoffsystemen die Zeitsignale einzelner Komponenten selektiert werden. Der Meßvorgang ist über die Potentiale kontrollierbar, die dem Nulldurchgang der Signalspannung im Kurvenverlauf der 2. Ableitung entsprechen.

Die Leistungsfähigkeit der Derivativ-Chronopotentiometrie wird durch die Ergebnisse von Untersuchungen mit Thallium(I)-lösungen veranschaulicht. Es werden bei den gegebenen Meßbedingungen stets empirische Transitionszeitwerte erhalten, die für analytische Belange auf experimentellem Wege einzeln korrigiert werden können.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Agasyan, P. K., Kamenev, A. I., Lunev, M. I.: Zh. Anal. Khim. 31, 121 (1976)

    Google Scholar 

  2. Bard, A. J.: Anal. Chem. 33, 11 (1961)

    Google Scholar 

  3. Bard, A. J.: Anal. Chem. 35, 340 (1963)

    Google Scholar 

  4. Bos, P.: J. Electroanal. Chem. 33, 379 (1971)

    Google Scholar 

  5. Davis, D. G.: Ealytical Chemistry (Band 1), herausgegeben von A. L. Bard, Marcel Dekker, New York 1966, p. 157

    Google Scholar 

  6. Delahay, P., Mamantov, G.: Anal. Chem. 27, 478 (1955)

    Google Scholar 

  7. Gierst, L., Mechelynck, Ph.: Anal. Chim. Acta 12, 79 (1955)

    Google Scholar 

  8. Iwamoto, R. T.: Anal. Chem. 31, 1062 (1959)

    Google Scholar 

  9. Lingane, J. J.: Analyst 91, 1078 (1966)

    Google Scholar 

  10. Paunovic, M.: J. Electroanal. Chem. 14, 447 (1967)

    Google Scholar 

  11. Peters, D. G., Burden, S. L.: Anal. Chem. 38, 530 (1966)

    Google Scholar 

  12. Reilley, C. N., Everett, G. W., Johns, R. H.: Anal. Chem. 27, 483 (1955)

    Google Scholar 

  13. Rodgers, R. S., Meites, L.: J. Electroanal. Chem. 16, 1 (1968)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Herrn Prof. Dr. Fritz Umland zum 60. Geburtstag gewidmet

Herrn K. H. Häuser danken wir für die tatkräftige Unterstützung beim Aufbau der elektronischen Meßanordnung.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Henze, G., Neeb, R. Derivativ-Chronopotentiometrie. Z. Anal. Chem. 310, 111–120 (1982). https://doi.org/10.1007/BF00481946

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00481946

Key words