Skip to main content
Log in

Neue Eichmethode zur Nitrat- und Nitrit-Spurenbestimmung in Lebensmittelproben

New calibration method for the nitrate and nitrite trace determination in food samples

  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Summary

A new analytical procedure for the determination of nitrate and nitrite traces in different food samples is described. Isotope dilution mass spectrometry is applied using a 15NO 3 and a 15NO 2 spike for the dilution technique and measuring negative NO 2 thermal ions in the mass spectrometer. This definitive method provides relatively accurate analysis results. Therefore, it is especially suitable as a calibration method. Nitrate contents in different milk powder samples and ham samples in the range of 3–170 ppm as well as dried samples of different plant materials in the range of 0.1–2% (by weight) are analysed. The determination of the plant material can also be carried out as micro analysis. So far as the food samples are homogeneous, the relative standard deviation of this method is in the range of 0.2–1% for nitrate contents of > 100 ppm and in the range of 1.5–3% for those of 10–100 ppm. The corresponding values for nitrite analysed in parallel to nitrate are 2–6% in the range of 1–50 ppm. The nitrate and nitrite detection limit is about 0.2 ppm.

Zusammenfassung

Ein neues Verfahren zur Nitrat- und Nitritspurenbestimmung in verschiedenartigen Lebensmittelproben wird beschrieben. Dazu wird die massenspektrometrische Isotopenverdünnungsanalyse unter Verwendung eines 15NO 3 - und 15NO 2 -Indicators sowie die Messung negativer NO 2 -Thermionen im Massenspektrometer eingesetzt. Als definitive Methode liefert dieses Verfahren vergleichsweise richtige Analysenergebnisse, weshalb es sich vor allem auch als Eichverfahren eignet. Es werden Nitratgehalte in verschiedenen Milchpulver- und Schinkenproben im Bereich 3–170 ppm sowie getrocknete Proben von Pflanzenmaterialien im Bereich 0,1–2 Gew.-% analysiert. Dabei kann die Bestimmung letztgenannter Proben auch als Mikroanalyse erfolgen. Soweit es sich bei den Lebensmitteln um homogenisierte Proben handelt, liegen bei Konzentrationen >100 ppm die relativen Standardabweichungen des Verfahrens im Bereich 0,2–1%, bei Gehalten von 10–100 ppm im Bereich 1,5–3%. Die entsprechende Reproduzierbarkeit für parallel zum Nitrat bestimmtes Nitrit liegt bei 2–6% für Gehalte im Bereich 1–50 ppm. Die Nachweisgrenze für Nitrat und Nitrit ist etwa 0,2 ppm.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Kuhlen H (1962) 16th Int Horticult Congr Brüssel, vol 1. Gemblaux

  2. White SW (1975) J Agric Food Chem 23:886

    Article  CAS  Google Scholar 

  3. Schindlmeier W, Heumann KG (1985) Fresenius Z Anal Chem 320:Heft 8

  4. Heumann KG, Seewald H (1985) Fresenius Z Anal Chem 320:494

    Google Scholar 

  5. Unger M, Heumann KG (1983) Int J Mass Spectrom Ion Phys 48:373

    Article  CAS  Google Scholar 

  6. Weast RC (Editor) (1977/78) Handbook of chemistry and physics, 58. Aufl. The Chem Rubber Comp, Cleveland

    Google Scholar 

  7. Heumann KG, Unger M (1983) Fresenius Z Anal Chem 315:454

    Article  CAS  Google Scholar 

  8. Schmidt M, Heumann KG, Schindlmeier W, Zeininger H (1985) Fresenius Z Anal Chem 320:457

    Article  Google Scholar 

  9. Achtzehn MK, Hawat H (1969) Nahrung 13:667

    Article  Google Scholar 

  10. Community Bureau of Reference BCR (1981) Project 222, Reference materials for the analysis of trace elements and nitrate in milkpowder, Brussels

  11. IMV-Standard 95 (1981) Milchwissenschaft 36:472

    Google Scholar 

  12. Grau R, Mirna A (1957) Fresenius Z Anal Chem 158:182

    Article  CAS  Google Scholar 

  13. Heumann KG, Kastenmayer P, Zeininger H (1981) Fresenius Z Anal Chem 306:173

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Vortrag anläßlich des Symposiums Anorganische Anionenanalytik, Regensburg, 19.–21. 9. 1984

Der Deutsche Forschungsgemeinschaft und dem Fonds der Chemischen Industrie danken wir für die finanzielle Unterstützung.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Unger, M., Heumann, K.G. Neue Eichmethode zur Nitrat- und Nitrit-Spurenbestimmung in Lebensmittelproben. Z. Anal. Chem. 320, 525–529 (1985). https://doi.org/10.1007/BF00479825

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00479825

Navigation