Summary
Wet deposition of acid onto the vegetation blanket and the surface of fresh waters is of increasing importance for the estimation of environmental damages.
Ion-chromatography has been evaluated as a suitable tool for the determination of the most important anions present in rain water. These anions are partly present as anionic components of the totally dissociated strong acids H2SO4, HNO3, and HCl responsible for the acidity of the rain. The advantages of the method are sufficient sensitivity, automation, the possibility of a direct simultaneous determination of the three anions and small sample volume. The most frequent sources of error can occur in the sampling step, during sample storage and due to insufficient cleaning of the sampling bottles and the components of the rain water sampler.
As a practical application of ion-chromatography the concentrations of the three most important anions were determined in rain water samples taken in 1983. Sampling was performed at four sampling sites of the Stolberg-Juelich region: Juelich-Hambach, Stolberg-Werth, Stolberg-Gressenich or Stolberg-Muensterbusch und Stolberg-Binsfeldhammer. The anion concentrations varied in the ranges 0.2–7 mg/l Cl−, 0.5–10 mg/l NO −3 and 2–20 mg/l SO 2−4 and had a standard deviation up to 15%.
Zusammenfassung
Der Säureeintrag mit der Naßdeposition auf die Vegetationsdecke und die Gewässer ist für die Beurteilung vieler Umweltschäden von wachsender Bedeutung.
Es wird über die Ionen-Chromatographie als Analyseverfahren der wichtigsten im Regen enthaltenen Anionen berichtet. Diese Anionen fungieren teilweise als anionische Komponenten der für den Säuregrad des Regens verantwortlichen starken vollständig dissoziierten Säuren H2SO4, HNO3 und in geringerem Ausmaß auch HCl. Als vorteilhaft haben sich die ausreichende Empfindlichkeit der Ionen-Chromatographie, ihre Automatisierung, die Möglichkeit zur simultanen Bestimmung der drei Anionen, das kleine Probenvolumen und die Möglichkeit der direkten Injektion der Probe ohne weitere Vorbereitung erwiesen. Die häufigsten Fehlerquellen bei der Bestimmung der Anionen liegen in der Probennahme, der Probenlagerung sowie in der unzulänglichen Reinigung der Regensammlerteile und der Aufbewahrungsgefäße.
Als praktisches Anwendungsbeispiel werden ionen-chromatographisch bestimmte Anionenkonzentrationen in Regenproben aus dem Jahre 1983 vorgestellt und diskutiert. Die Probennahme erfolgte an vier Sammelstellen im Raum Stolberg-Jülich: Jülich-Hambach, Stolberg-Werth, Stolberg-Gressenich bzw. Stolberg-Münsterbusch und Stolberg-Binsfeldhammer. Die Anionenkonzentrationen variierten zwischen 0,2–7 mg/l Cl−, 0,5–10 mg/l NO −3 und 2–10 mg/l SO 2−4 . Die maximale Standardabweichung betrug 15%.
Similar content being viewed by others
Literatur
Beilke S (1982) In: Acid deposition, Proc CEC Workshop ‘Physico-Chemical Behaviour of Atmospheric Pollutants’, Commission of the European Communities, Brussels, S 3–30
Rat von Sachverständigen für Umweltfragen (1983) Waldschäden und Luftverunreinigungen, Sondergutachten. W. Kohlhammer, Stuttgart
Nguyen VD, Valenta P, Nürnberg HW (1979) Sci Total Environ 12:151–167
Nürnberg HW, Valenta P, Nguyen VD (1982) In: Georgii HW, Pankrath J (eds) Deposition of atmospheric pollutants. D. Reidel, Publishing Comp., Dordrecht Boston, pp 143–157
Nürnberg HW, Valenta P, Nguyen VD (1983) In: AGF-Tagung Luftreinhaltung-Luftverschmutzung, Nov. 1983, Bonn, S 53–57
Nürnberg HW, Valenta P, Nguyen VD (1983) Proc Int Conf Heavy Metals in the Environment, Sept. 1983, Heidelberg, Vol 1. CEP Consultants, Edinburgh 1983, pp 70–77
Nürnberg HW, Valenta P, Nguyen VD, Gödde M, Urano de Carvalho E (1984) Fresenius Z Anal Chem 317:314–323
Nürnberg HW, Valenta P, Nguyen VD (1980) In: Jahresbericht 1979/80 der KFA Jülich, S 47–54
Nürnberg HW, Nguyen VD, Valenta P (1983) In: Jahresbericht 1982/83 der KFA Jülich, S 41–53
Nürnberg HW, Valenta P, Nguyen VD (1983) In: Ministerium für Arbeit, Gesundheit und Soziales NRW (Hrsg), Umweltprobleme durch Schwermetalle im Raum Stolberg 1983, Anh III. Diederichs, Düsseldorf, S 1–11
Wagner F (1985) Dissertation, RWTH Aachen
Nguyen VD, Valenta P (1978) Dt Patent 2831 840.3
Gravenhorst G, Perseke E, Rohbock E (1980) Untersuchungen über die trockene und feuchte Deposition in der Bundesrepublik Deutschland. Universitätsinstitut für Meteorologie und Geophysik Frankfurt/M, Forschungsprojekt 10402600, UBA, Berlin
Perseke C, Georgii HW (1979) Probleme und Stand der Kenntnisse auf dem Gebiet der trockenen und nassen Deposition. Berichte des Institutes für Meteorologie und Geophysik der Universität Frankfurt/M, Nr. 38
Georgii HW, Perseke C, Rohbock E (1982) Feststellung der Deposition von sauren und langzeitwirksamen Luftverunreinigungen aus Belastungsgebieten. Universitätsinstitut für Meteorologie und Geophysik der Universität Frankfurt/M, Forschungsprojekt 10402600, UBA, Berlin
Peden ME, Skowton LM (1978) Atmos Environment 12:2343–2349
Galloway JN, Likens GE (1976) Water, Air, Soil Pollut 6:241–258
Galloway JN, Lekins GE (1978) Tellus 30:71–82
Hamish S, Stevens TS, Bauman WC (1975) Anal Chem 47:1801–1809
Crowther J, McBride J (1981) Analyst 106:702–709
Wetzel R (1979) Environ Sci Technol 13:1214–1217
Tabatabai MA, Dick WA (1983) J Environ Qual 12:209–213
Janson KH (1978) Labor Praxis 3:30–34
Mulik J, Puckett R, Williams D, Sawicki E (1976) Analyt Lett 9:653–665
Manual, Dionex Auto IonTM System 12 Analyser
Brecht Ch, Goethe HG, Krämer H, Reintges H, Willing H-G (1981) Jahrbuch für Bergbau, Energie, Mineralöl und Chemie 1980/81, Glückauf, Essen
Geiss, H, KFA, persönl Mitt
Gilbert SR, Hayes JV (1983) In: Pruppacher HR, Semonin RG, Slinn WGN (eds) Precipitation scavenging, dry deposition and resuspension, vol 1. Elsevier, New York Amsterdam Oxford, p 249
Rödel W (1980) Vorlesung: Aerosole, Sommersemester (1980) Institut für Umweltphysik, Univ Heidelberg
Lodge JP Jr, Pate JB, Basbergill W, Swanson GS, Hill KC, Lorange E, Lazrus AL (1968) Chemistry of United States Precipitation Final Report on the National Precipitation Sampling Network, National Center for Atmospheric Research, Boulder, Colorado
Ulrich B, Mayer R, Khanna PK (1979) Schriften aus der Forstlichen Fakultät der Universität Göttingen und der Niedersächsischen Forstlichen Versuchsanstalt, 58, S 251
Author information
Authors and Affiliations
Additional information
Auszugsweise vorgetragen beim Symposium Anorganische Anionenanalytik, Regensburg, 19.–21. 9. 1984
Entnommen aus der Dissertation von Dipl.-Phys. F. Wagner, RWTH Aachen 1985
Rights and permissions
About this article
Cite this article
Wagner, F., Valenta, P. & Nürnberg, H.W. Ionen-chromatographische Bestimmung der Anionen Cl−, NO −3 und SO 2−4 in Regenwasser. Z. Anal. Chem. 320, 470–476 (1985). https://doi.org/10.1007/BF00479814
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/BF00479814