Summary
A new sample introduction technique for liquid and solid samples called SET (Sample Elevator Technique) is described here. SET is only practical using the high-power inductively coupled plasma. Preliminary condition is a stable burning ICP in an unclosed tube system.
A graphite crucible containing 10 mg or 10 μl of sample is inserted directly into the plasma using a pneumatic elevator device and heated up inductively. After some seconds the crucible is becoming white-hot. The sample material is vapourized into the hot centre of the plasma without a carrier gas flow. Thus, the residence time of the vapour seems to be sufficient. The detection limits are improved by one order of magnitude and more using SET compared with the solution nebulization technique.
Zusammenfassung
Es wird eine neue Methode zur direkten Probeneinführung in flüssiger und fester Form beschrieben, die SET genannt wurde und nur in Verbindung mit dem Plasma hoher Leistung praktisch anwendbar ist. Voraussetzung hierfür ist ein stabil brennendes Plasma in einem offenen Brennerrohr.
Mit Hilfe einer pneumatischen Vorrichtung, die wie ein Fahrstuhl arbeitet, wird ein Graphittiegel mit 10 mg oder 10 μl Probesubstanz direkt in das Plasma eingeführt. Der Tiegel wird induktiv aufgeheizt und erreicht nach einigen Sekunden Weißglut. Ohne die Verwendung eines Trägergases wird das Probegut direkt in das heiße Zentrum des Plasmas verdampft, wobei die Verweilzeit des Dampfes auszureichen scheint.
Die Nachweisgrenzen werden auf diese Weise gegenüber der Methode mit zerstäubten Lösungen um eine Zehnerpotenz und mehr verbessert.
Similar content being viewed by others
Literatur
Barnes, R. M., Genna, J. S.: Anal. Chem. 51, 1065 (1979)
Boumans, P. W. J. M., Bosveld, M.: Spectrochim. Acta 34B, 59 (1979)
Broekaert, J. A. C., Leis, F., Laqua, K.: Fresenius Z. Anal. Chem. 301, 105 (1980)
Dahlquist, R. L., Knoll, J. W., Hoyt, R. E.: 26. Pittsburgh Conference, Cleveland 1975
Greenfield, S., Jones, I. L., McGeachin, H. McD., Smith, P. B.: Anal. Chim. Acta 74, 225 (1975)
Gunn, A. M., Millard, D. L., Kirkbright, G. F.: Analyst 103, 1066 (1978)
Kirkbright, G. F.: International Winter Conference, San Juan 1980
Kirkbright, G. F., Snook, R. D.: Anal. Chem. 51, 1938 (1979)
Nixon, D. E., Fassel, V. A., Kniseley, R. N.: Anal. Chem. 46, 210 (1974)
Ohls, K., Sommer, D.: International Winter Conference, San Juan 1980
Salin, E. D., Horlick, G.: Anal. Chem. 51, 2284 (1979)
Sommer, D., Ohls, K.: Fresenius Z. Anal. Chem. 295, 337 (1979)
Sommer, D., Ohls, K.: Niederl.-deutsche Arbeitstagung, Vennenbos 1979
Vukanović, D., Simić, M., Kovačić, N., Vukanović, V., Nickel, H., Mazurkiewicz, M.: Spectrochim. Acta 32B, 445 (1977)
Winge, R. K., Fassel, V. A., Kniseley, R. N.: Appl. Spectrosc. 25, 636 (1971)
Winge, R. K., Peterson, V. J., Fassel, V. A.: Appl. Spectrosc. 33, 206 (1979)
Wittmann, A., Hughes, H., Hancart, J., Ohls, K.: International Winter Conference, San Juan 1980
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Sommer, D., Ohls, K. Direkte Probeneinführung in ein stabil brennendes, induktiv gekoppeltes Plasma. Z. Anal. Chem. 304, 97–103 (1980). https://doi.org/10.1007/BF00474365
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00474365