Remote and in-situ analysis

  • Tomas Hirschfeld
Lectures

Summary

As analysis continues to move out from the laboratory into the factory, the high cost of multiple on-line instruments and the conservative technology needed for unattended operation in a hostile environment have become serious limitations.

Remote measurements, using selective optical sensors (“optrodes”) at the end of a fiber optic network operated by a single central instrument, are a solution to these problems. They allow the instrument to stay in the benign environment and high support level of the laboratory, while the low cost sensors can be multiplied to provide extensive and cost effective monitoring.

A further trend, as yet in its infancy, is the movement of analytical and diagnostic capability out from the production line into the product. A number of low cost disposable sensors for this application will be described.

Keywords

Optic Network Diagnostic Capability Remote Measurement Conservative Technology Benign Environment 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Externe und In-situ-Analyse

Zusammenfassung

Mit der fortschreitenden Verlagerung der Analysen aus den Labors in die Produktionsstätten werden die hohen Kosten für die notwendige Zahl von on-line betriebenen Instrumenten und der Aufwand für ihren unbeaufsichtigten Betrieb unter ungünstigen Bedingungen zu ernstlichen Hindernissen.

Eine Lösung für diese Probleme ist der Einsatz von selektiven optischen Sensoren („Optroden“), die über Fiberoptik mit einem einzigen zentralen Instrument verbunden sind. Dadurch ist der Betrieb des Instrumentes unter den günstigen Bedingungen des Labors und gleichzeitig eine extensive und kostengünstige Überwachung durch eine Vielzahl von billigen Sensoren möglich.

Ein weiterer Trend, der allerdings noch in den Kinderschuhen steckt, ist die Verlagerung der analytischen und diagnostischen Möglichkeiten aus der Produktion in das Produkt. Einige billige Sensoren für solche Anwendungen werden vorgestellt.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Giuliani JF, Wohltjen H, Jarvis NL (1983) Opt Lett 8:54Google Scholar
  2. Hirschfeld T (1980) Long distance analysis via communications optical cables, Energy Technol Rev 17Google Scholar
  3. Hirschfeld T (1984) System monitoring and reliability assessment through microengineering, Energy Technol Rev 16Google Scholar
  4. Hirschfeld T, Callis J, Kowalski B (1984) Chem Sensors Proc Anal 226:312Google Scholar
  5. Hirschfeld T (1985) Science, to be publishedGoogle Scholar
  6. Lubbers DW, Opitz N (1983) Sensors Actual 4:641Google Scholar
  7. Milanovich FP, Hirschfeld T (March 1984) Remote fiber fluorimetry: using optics for on-stream analysis, Intech, 33Google Scholar
  8. Olness D, Hirschfeld T (1985) Anal Chem (submitted)Google Scholar
  9. Peterson JI, Fitzgerald RV (1984) Anal Chem 56:62Google Scholar
  10. Saari LA, Seitz WR (1984) Anal Chem 56:16AGoogle Scholar

Copyright information

© Springer-Verlag 1986

Authors and Affiliations

  • Tomas Hirschfeld
    • 1
  1. 1.Lawrence Livermore National LaboratoryLivermoreUSA

Personalised recommendations