Abstract
The search for prosthetic materials that are biocompatible, nontoxic, and permanent led the authors to develop a micronized, inert, biphasic polymer particle for permanent soft tissue augmentation which neither migrates nor is absorbed by the body. Placed in a bioexcretable gel carrier, these textured microparticles are easily implanted using a specially designed blunt-tipped cannula with local anesthesia on an outpatient basis. Research using this implant material, BioplastiqueTM (Bioplasty, St. Paul, MN), in rabbits has shown that when the textured particle size is maintained within a critical range, neither particle migration nor storage disease occurs. The gel carrier is rapidly phagocytized and replaced by fibrin matrix within a few days. Host collagen then gradually forms a fibrotic capsule around each textured particle, making use of the naturally occurring foreign body reaction to create a stable inplant. After being followed for over two years, Bioplastique has proven to be useful in many clinical applications with few complications.
Similar content being viewed by others
References
Chao Y, Humphreys S, Penfield W: A new method of preventing adhesions: the use of amniplastin after craniotomy. Br Med J 1:517–519, 1940
Davidson RL (ed): Handbook of Water Soluble Gums & Resins. New York: McGraw-Hill, 1980, chap 21
Ersek RA: Prostheses for breast augmentation: Progress in materials and the design of these implants continues. Travis County Med Soc J 8–10, May 1989
Ersek RA: Transplantation of purified autologous fat: a 3-year follow-up is disappointing. Plast Reconstr Surg 87(2):219–227, 1991
Ersek RA, Kjellstrans C, Lillehei RC: A new arteriovenous shunt design. ASAIO, XV: 267, 1969 (U.S. Pat. No. 3,638,649, Implantable Prosthetic Device, 1972)
Ersek RA et al: Processed bovine cartilage: an improved biosynthetic implant for contour defects. Ann Plast Surg 12(5):397–408, 1984
Muscona R: Free fat injections for the correction of hemifacial atrophy. Plast Reconstr Surg 85(3):501, 1989
Robinson BV, Sullivan FM, Borzelleca JF, Schwartz SL: PVP: A Critical Review of the Kinetics and Toxicology of Polyvinylpyrrolidone (Povidone). Chelsea, MI: Lewis Publishers, Inc., 1990
Smahel J: Tissue reactions to breast prostheses coated with polyurethane. Plast Reconstr Surg 61:80, 1978
Symmers WStC: Silicone mastitis in “topless” waitresses & some other varieties of foreign body mastitis. Br Med J 3:19, 1968
The prevention of postoperative adhesions between the cortex and dura. Univ Penn Med Bull 22:57–61, 1909
Trentham DE: Adverse reactions to bovine collagen implants. Arch Dermatol 122:643–644, 1986
Vilar SB: An old story: an ivory nasal implant. Aesth Plast Surg 11:157, 1987
Whalen RL: Connective tissue response to movement at the prosthesis /tissue interface. In: Zycher M (ed): Biocompatible Polymers, Metals & Composities. Lancaster, PA: Technomic Pub. Co., 1983
Author information
Authors and Affiliations
Additional information
Note: The authors are inventors of Bioplastique and have a financial interest in it.
Rights and permissions
About this article
Cite this article
Ersek, R.A., Beisang, A.A. BioplastiqueTM : A new biphasic polymer for minimally invasive injection implantation. Aesth. Plast. Surg. 16, 59–65 (1992). https://doi.org/10.1007/BF00455150
Issue Date:
DOI: https://doi.org/10.1007/BF00455150