Skip to main content

Advertisement

Log in

Bone formation in porous implants of delrin and commercially pure titanium

  • Clinical and Experimental Forum
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Summary

Clinicians have been using implants made by titanium or delrin with varying results. In this study dividable implants, bone growth chambers (BGC), of titanium and delrin were inserted into the rabbit tibia. The ingrowth of hard tissue into a canal in the implant was evaluated after 3 weeks by microradiography and numerically determined by computer analysis. Results showed that bone ingrowth into titanium implants was significantly larger than into delrin implants (P < 0.005). The possible reasons for this are discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Albrektsson T (1984) Osseous penetration rate into implants pretreated with bone cement. Arch Orthop Trauma Surg 102:141–147

    Google Scholar 

  2. Albrektsson T (1985) The response of bone to titanium implants. CRC Crit Rev Biocompatibility 1:53–84

    Google Scholar 

  3. Albrektsson T, Bach A, Edshage S, Musson A (1982) Fibrin adhesive system (FAS) influence on the bone healing rate. A microradiographical evaluation using the bone growth chamber. Acta Orthop Scand 53:757–763

    Google Scholar 

  4. Buch F, Albrektsson T, Herbst E (1984) Direct current influence on bone formation in titanium implants. Biomaterials 5:341–346

    Google Scholar 

  5. Buch F, Albrektsson T, Herbst E (1985) Effects of direct current on bone growth into delrin implants. Scand J Plast Reconstr Surg 19:223–230

    Google Scholar 

  6. Bruck SD (1980) Properties of biomaterials in the physiological environment. CRC Press, Boca Raton, pp 1–142

    Google Scholar 

  7. Dumbleton JH (1979) Delrin as a material for joint prostheses. In: Syrett BC, Acharya A (eds) Corrosion and degradation of implant materials. ASTM STP 684. American Society for Testing and Materials, Philadelphia, pp 41–46

    Google Scholar 

  8. Eriksson A, Albrektsson T (1984) The effect of heat on bone regeneration. J Oral Maxillofac Surg 42:705–711

    Google Scholar 

  9. Fister JS, Memoli VA, Galante JO, Rostoher W, Urban RM (1985) Biocompatibility of delrin 150: a creep-resistant polymer for total joint prosthesis. J Biomed Mater Res 19:519–527

    Google Scholar 

  10. Gibbons DF (1982) Materials for orthopaedic joint prostheses. In: Williams DF (ed) Biocompatibility of orthopedic implants, vol 1. CRC Press, Boca Raton, pp 111–139

    Google Scholar 

  11. Jacobsson M, Jönsson A, Albrektsson T, Turesson I (1985) Short and long-term effects of irradiation on bone regeneration. J Plast Reconstr Surg 76:841–848

    Google Scholar 

  12. Sundal B, Kalvie H, Christiansen T (1974) Total hip replacement with a new trunnion-bearing prosthesis. Acta Chir Scand 140:189–198

    Google Scholar 

  13. Thomsen P, Bjursten L-M, Ericson LE (1986) Implants in the abdominal wall of the rat. Scand J Plast Reconstr Surg 20:173–182

    Google Scholar 

  14. Wright KWJ (1982) Friction and wear of materials and joint replacement prostheses. In: Williams DF (ed) Biocompatibility of orthopedic implants, vol 1. CRC Press, Boca Raton, pp 141–195

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This study was supported by grants from the Swedish Medical Research Council (B 84-12P-6475-02) and B 84-12X-6533-02), King Gustaf V Jubilee Foundation, Trygg-Hansa Research Fund, the Gothenburg Medical Society, and the Greta and Einar Askers Foundation.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Buch, F., Alhrektsson, T. Bone formation in porous implants of delrin and commercially pure titanium. Arch Orthop Trauma Surg 109, 227–230 (1990). https://doi.org/10.1007/BF00453147

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00453147

Keywords

Navigation