Skip to main content
Log in

Femoral shaft perforation at arthroplasty: To treat or not to treat

  • Clinical and Experimental Forum
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Summary

Femoral shaft perforation at total hip arthroplasty is a complication that is being noted more frequently, and it is often associated with femoral shaft fracture below the prosthesis. This study examines the anatomic and biomechanical effects of femoral shaft perforation at arthroplasty, and the effects of supporting the perforated bone with Partridge plates and bands. Two models, pig femora and Pedilen cylinders, were employed. Testing the bone models to failure in tensile mode showed that the perforations weakened the bone and that the Partridge plates and bands decreased the weakening effects of the perforation. The strengthening effect of the Partridge plates and bands on the bone with a perforation, allied with the presence of an internal splint in the event of a fracture through the perforation, suggests the benefit of using Partridge plates and bands if a cortical perforation is found at arthroplasty and revision is not feasible.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Amstutz HC, Steven MA, Jinnah RH, Mai L (1982) Revision of aseptic loose total hip arthroplasties. Clin Orthop 170:21–33

    Google Scholar 

  2. Bechtel GO (1977) Engineering principles applied to orthopaedic surgery. J Bone Joint Surg [Am] 59:257–264

    Google Scholar 

  3. Bethea SJ, De Andrade JR, Fleming LL, Lindenbaum SD, Welch RB (1982) Proximal femoral fractures following total hip arthroplasty. Clin Orthop 170:95–106

    Google Scholar 

  4. Burnstein AH, Curry J, Frankel VH, Heip KG (1970) Bone strength. The effect of screw holes. J Bone Joint Surg [Am] 54:1143–1156

    Google Scholar 

  5. Callaghan JJ, Salvati EA, Pellicci PM, Wilson PD, Ranawat CS (1985) Results of revision for mechanical failure after cemented total hip replacements, 1979–1982. J Bone Joint Surg [Am] 67:1074–1085

    Google Scholar 

  6. Harris WH (1982) Revision surgery for failed non-septic total hip arthroplasty. Clin Orthop 170:8–20

    Google Scholar 

  7. Kavanagh BF, Ilstrup DM, Fitzgerald HR (1985) Revision total hip replacement. J Bone Joint Surg [Am] 67:517–526

    Google Scholar 

  8. McElfresh EC, Coventry MB (1974) Femoral and pelvic fractures after total hip arthroplasty. J Bone Joint Surg [Am] 56:483–492

    Google Scholar 

  9. Partridge AJ (1982) Development and clinical application of nylon circlage. Contemp Orthop 4:74–80

    Google Scholar 

  10. Pellicci PM, Inglis A, Salvati EA (1980) Perforation of the femoral shaft at total hip replacement. J Bone Joint Surg [Am] 62:234–240

    Google Scholar 

  11. Scott RD, Turner RH, Leitzes AM, Aufranc OE (1975) Femoral fractures in conjunction with total hip replacement. J Bone Joint Surg [Am] 57:492–501

    Google Scholar 

  12. Stromberg L, Karlstrom G (1986) The influence of nylon circlage on diaphyseal bone strength. Orthopaedics 9:237–239

    Google Scholar 

  13. Talab YA, States JD, Ewarts C (1979) Femoral shaft perforation. Clin Orthop 171:158–165

    Google Scholar 

  14. Woolson ST, Harris WH (1983) Complex total hip replacement for dysplastic or hypoplastic hips using miniature or microminiature components. J Bone Joint Surg [Am] 65

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Doyle, J., Procter, P. & Moloney, M.A. Femoral shaft perforation at arthroplasty: To treat or not to treat. Arch Orthop Trauma Surg 109, 217–220 (1990). https://doi.org/10.1007/BF00453144

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00453144

Keywords

Navigation