Summary
Femoral shaft perforation at total hip arthroplasty is a complication that is being noted more frequently, and it is often associated with femoral shaft fracture below the prosthesis. This study examines the anatomic and biomechanical effects of femoral shaft perforation at arthroplasty, and the effects of supporting the perforated bone with Partridge plates and bands. Two models, pig femora and Pedilen cylinders, were employed. Testing the bone models to failure in tensile mode showed that the perforations weakened the bone and that the Partridge plates and bands decreased the weakening effects of the perforation. The strengthening effect of the Partridge plates and bands on the bone with a perforation, allied with the presence of an internal splint in the event of a fracture through the perforation, suggests the benefit of using Partridge plates and bands if a cortical perforation is found at arthroplasty and revision is not feasible.
Similar content being viewed by others
References
Amstutz HC, Steven MA, Jinnah RH, Mai L (1982) Revision of aseptic loose total hip arthroplasties. Clin Orthop 170:21–33
Bechtel GO (1977) Engineering principles applied to orthopaedic surgery. J Bone Joint Surg [Am] 59:257–264
Bethea SJ, De Andrade JR, Fleming LL, Lindenbaum SD, Welch RB (1982) Proximal femoral fractures following total hip arthroplasty. Clin Orthop 170:95–106
Burnstein AH, Curry J, Frankel VH, Heip KG (1970) Bone strength. The effect of screw holes. J Bone Joint Surg [Am] 54:1143–1156
Callaghan JJ, Salvati EA, Pellicci PM, Wilson PD, Ranawat CS (1985) Results of revision for mechanical failure after cemented total hip replacements, 1979–1982. J Bone Joint Surg [Am] 67:1074–1085
Harris WH (1982) Revision surgery for failed non-septic total hip arthroplasty. Clin Orthop 170:8–20
Kavanagh BF, Ilstrup DM, Fitzgerald HR (1985) Revision total hip replacement. J Bone Joint Surg [Am] 67:517–526
McElfresh EC, Coventry MB (1974) Femoral and pelvic fractures after total hip arthroplasty. J Bone Joint Surg [Am] 56:483–492
Partridge AJ (1982) Development and clinical application of nylon circlage. Contemp Orthop 4:74–80
Pellicci PM, Inglis A, Salvati EA (1980) Perforation of the femoral shaft at total hip replacement. J Bone Joint Surg [Am] 62:234–240
Scott RD, Turner RH, Leitzes AM, Aufranc OE (1975) Femoral fractures in conjunction with total hip replacement. J Bone Joint Surg [Am] 57:492–501
Stromberg L, Karlstrom G (1986) The influence of nylon circlage on diaphyseal bone strength. Orthopaedics 9:237–239
Talab YA, States JD, Ewarts C (1979) Femoral shaft perforation. Clin Orthop 171:158–165
Woolson ST, Harris WH (1983) Complex total hip replacement for dysplastic or hypoplastic hips using miniature or microminiature components. J Bone Joint Surg [Am] 65
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Doyle, J., Procter, P. & Moloney, M.A. Femoral shaft perforation at arthroplasty: To treat or not to treat. Arch Orthop Trauma Surg 109, 217–220 (1990). https://doi.org/10.1007/BF00453144
Issue Date:
DOI: https://doi.org/10.1007/BF00453144