Abstract
The usefulness of fluorescence techniques for the study of macromolecular structure and dynamics depends on the accuracy and sensitivity of the methods used for data analysis. Many methods for data analysis have been proposed and used, but little attention has been paid to the maximum likelihood method, generally known as the most powerful statistical method for parameter estimation. In this paper we study the properties and behavior of maximum likelihood estimates by using simulated fluorescence intensity decay data. We show that the maximum likelihood method provides generally more accurate estimates of lifetimes and fractions than does the standard least-squares approach especially when the lifetime ratios between individual components are small. Three novelties to the field of fluorescence decay analysis are also introduced and studied in this paper: a) discretization of the convolution integral based on the generalized integral mean value theorem: b) the likelihood ratio test as a tool to determine the number of exponential decay components in a given decay profile; and c) separability and detectability indices which provide measures on how accurately, a particular decay component can be detected. Based on the experience gained from this and from our previous study of the Padé-Laplace method, we make some recommendations on how the complex problem of deconvolution and parameter estimation of multiexponential functions might be approached in an experimental setting.
This is a preview of subscription content, access via your institution.
References
Alcala JR, Gratton E, Prendergast FG (1987) Interpretation of fluorescence decays in proteins using continuous lifetime distributions. Biophys J 51:925–936
Ameloot M, Hendrickx H (1983) Extension for the performance of Laplace deconvolution in the analysis of fluorescence decay curves. Biophys J 44:27–38
Ameloot M, Beechem JM, Brand L (1986) Simultaneous analysis of multiple fluorescence decay curves by Laplace transforms. Deconvolution with reference or excitation profiles. Biophys Chem 23: 155–171
Andre JC, Vincent LM, O'Connor D, Ware WR (1979) Applications of fast fourier transform to deconvolution in single photon counting. J Phys Chem 83:2285–2293
Awaya T (1979) A new method for curve fitting to the data with low statistics not using the χ2-method. Nucl Instrum Methods 165:317–323
Awaya T (1980) Application of a new method to the analysis of radioactive decays. Nucl Instrum Methods 174:237–242
Bajzer Ž, Sharp JC, Sedarous SS, Prendergast FG (1990a) Padé-Laplace method for the analysis of time resolved fluorescence decay curves. Eur Biophys J 18:101–115
Bajzer Ž, Sharp JC, Therneau TM, Prendergast FG (1990b) Comparison of the maximum likelihood and least squares methods for the analysis of time-resolved fluorescence decay curves. Biophys J 57:190a
Beechem JM, Gratton E (1988) Fluorescence spectroscopy data analysis environment: A second generation Global analysis program. In: Lakowicz RJ (ed) SPIE Proceedings: Time resolved laser Spectroscopy in Biochemistry 909:70–81
Beechem JM, Gratton E, MantulinWW (1990) GLOBALS UNLIMITED — Technical Reference Manual. Butzow JK (ed) Laboratory for Fluorescence Dynamics, University at Illinois, Department of Physics, Urbana
Bronshtein IN, Semendyayev KA (1985) Handbook of mathematics. Van Nostrand, New York
Cox DR, Hinkley DV (1974) Theoretical statistics. Chapman and Hall, London
Demas JN, Adamson AW (1971) Evaluation of photoluminescence lifetimes. J Phys Chem 75:2463–2466
Eaton DF (1990) Recommended methods for fluorescence decay analysis. Pure Appl Chem 62:1631–1648
Eisenfeld J, Ford CC (1979) A systems-theory approach to the analysis of multiexponential fluorescence decay. Biophys J 26:73–84
Gafni A, Modlin RL, Brand L (1975) Analysis of fluorescence decay curves by means of the Laplace transformation. Biophys J 15:263–280
Good HP, Kallir AJ, Wild UP (1984) Comparison of fluorescence lifetime fitting techniques. J Phys Chem 88:5435–5441
Gregory RB, Zhu Y (1990) Analysis of positron annihilation lifetime data by numerical Laplace inversion with the program CONTIN. Nucl Instrum Methods Phys Res A 290:172–182
Grinvald A, Steinberg IZ (1974) On the analysis of fluorescence decay kinetics by the method of least squares. Anal Biochem 59:583–598
Hall P, Selinger BK (1981) Better estimates of exponential decay parameters. J Phys Chem 85:2941–2946
Hall P, Selinger BK (1984) Better estimates of multiexponential decay parameters. Z Phys Chem NF 141:77–89
Haydock C, Sedarous SS, Bajzer Ž, Prendergast FG (1990) Fluorescence of variant-3 scorpion neurotoxin: multiple decay components and multiple tryptophan conformers. In: Lakowicz RF (ed) SPIE Proceedings: Time resolved laser Spectroscopy in Biochemistry II 1024:92–99
Hinde AL, Selinger BK, Nott PR (1977) On the reliability of fluorescence decay data. Aus J Chem 30:2383–2394
Isenberg I (1983) Robust estimation in pulse-fluorometry, a study of the method of moments and least squares. Biophys J 43:141–148
Isenberg I, Dyson RD (1969) The analysis of fluorescence decay by a method of moments. Biophys J 9:1337–1350
Janssens LD, Boens N, Ameloot M, De Schryver FC (1990) A systematic study of the global analysis of multiexponential fluorescence decay surfaces using reference convolution. J Phys Chem 94:3564–3576
Jezequel JY, Bouchy M, Andre JC (1982) Estimation of fast fluorescence lifetimes with single photon counting apparatus and the phase plane method. Anal Chem 54:2199–2204
Kendall MG, Stuart A (1979) The advanced theory of statistics, vol 2, 4th edn. Macmillan, New York
Kennedy WJ Jr, Gentle JE (1980) Statistical computing. Dekker, New York
Knutson JR, Beechem JM, Brand L (1983) Simultaneous analysis of multiple fluorescence decay curves: a global approach. Chem Phys Lett 102:501–507
Lehmann EL (1981) Theory of point estimation. Wiley, New York
Livesey AK, Brochon JC (1987) Analyzing the distribution of decay constants in pulse-fluorometry using the maximum entropy method. Biophys J 52:693–706
McCullagh P, Nelder JA (1983) Generalized linear models. Chapman and Hall, London
McKinnon AE, Szabo AG, Miller DR (1977) The deconvolution of photoluminiscence data. J Phys Chem 81:1564–1570
Meyer SL (1975) Data analysis for scientists and engineers. Wiley, New York
More JJ (1977) The Levenberg- Marquardt algorithm: implementation and theory. In: Watson GA (ed) Numerical analysis. Springer, New York Berlin Heidelberg
Morris AH Jr (1981) NSWC/DL library for mathematics subroutines. Naval surface weapons center. Dahlgren Vi, pp 183–184
Nelder JA, Mead R (1965) A simplex method for function minimization. Comput J 7:308–313
O'Connor DV, Phillips D (1984) Time-correlated single photon counting. Academic Press, New York
O'Connor DV, Ware WR, Andre JC (1979) The deconvolution of photoluminescence data. J Phys Chem 83:1333–1343
Olsson DM, Nelson LF (1975) Nelder-Mead simplex procedure for function minimization. Technometrics 17:45–51
Periasamy N (1988) Analysis of fluorescence decay by the nonlinear least squares method. Biophys J 54:961–967
Phillips GR, Eyring M (1988) Error estimation using the sequential simplex method in nonlinear least squares data analysis. Anal Chem 60:738–741
Press WH, Flannery BP, Teukolsky SA, Vetterling WT (1986) Numerical recipes. Cambridge University Press, Cambridge
Provencher SW (1982a) A constrained regularization method for inverting data represented by linear algebraic or integral equations. Comp Phys Comm 27:213–227
Provencher SW (1982b) CONTIN: a general purpose constrained regularization program for inverting noisy linear algebraic and integral equations. Comp Phys Comm 27:229–242
Sandor T, Conroy MF, Hollenberg NK (1970) The application of the method of maximum likelihood to the analysis of tracer kinetic data. Math Biosci 9:149–159
Selinger BK, Harris CM (1983) A critical appraisal of analytical methods. NATO ASI (Adv Sci Inst) Ser A Life Sci 69:155–168
Siemiarczuk A, Wagner BD, Ware WR (1990) Comparison of the maximum entropy and exponential series methods for the recovery of distributions of lifetimes from fluorescence lifetime data. J Phys Chem 94:1661–1666
Small EW, Libertini LJ, Brown DW, Small JR (1989) Extensions of the method of moments for deconvolution of experimental data. In: Menzel ER (ed) SPIE Proceedings: Fluorescence Detection III 1054:36–53
Szabo AG, Bramal L (1983) Modulating functions — a deconvolution method. NATO ASI (Adv Sci Inst) Ser A Life Sci 69:271–283
Valeur B, Moirez J (1973) Analyse des courbes de décroissance multiexponentielles par la méthode des fonctions modulatrices — application à la fluorescence. J Chim Phys 70:500–506
Ware WR, Doemeny LJ, Nemzek TL (1973) Deconvolution of fluorescence and phosphorescence decay curves. A least-squares method. J Phys Chem 77:2038–2048
Willis KJ, Szabo AG, Zuker M, Ridgeway JM, Alpert B (1990) Fluorescence decay kinetics of the tryptophyl residues of myoglobin: Effects of heme ligation and evidence for discrete lifetime components. Biochemistry 29:5270–5275
Wong AL, Harris JM (1989) Quantitative estimation of component amplitudes in multiexponential data: Application to time-resolved fluorescence spectroscopy. Anal Chem 61:2310–2315
Author information
Authors and Affiliations
Additional information
Offprint requests to: F. G. Prendergast
Rights and permissions
About this article
Cite this article
Bajzer, Ž., Therneau, T.M., Sharp, J.C. et al. Maximum likelihood method for the analysis of time-resolved fluorescence decay curves. Eur Biophys J 20, 247–262 (1991). https://doi.org/10.1007/BF00450560
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00450560