Skip to main content

Advertisement

Log in

Biodegradable wire fixation in olecranon and patella fractures combined with biodegradable screws or plugs and compared with metallic fixation

  • Original Article
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

The outcome of olecranon and patella fractures fixed with biodegradable implants (self-reinforced poly-l-lactide wire combined with self-reinforced polyglycolide screw or self-reinforced poly-l-lactide plug) or with metallic implants (tension band wiring, Kirschner wire and metallic cerclage wire) was compared in a prospective, randomized study. Twenty-five olecranon fractures (15 with biodegradable implants and 10 with metallic ones) and 10 patella fractures (6 with biodegradable implants and 4 with metallic ones) were treated. There were no differences between these methods in outcome. Olecranon and patella fractures can be treated using biodegradable implants successfully. The total expenses are lower because a second operation is not needed to remove the implants after fracture consolidation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Böstman O, Kiviluoto O, Santavirta S, Nirhamo J, Wilppula E (1983) Fractures of the patella treated by operation. Arch Orthop Trauma Surg 102:78–81

    Google Scholar 

  2. Bray TJ, Marder RA (1988) Patellar fractures. In: Chapman MW, Madison M (eds) Operative orthopaedics. Lippincott, Philadelphia, pp 413–420

    Google Scholar 

  3. Curtis MJ (1990) Internal fixation for fractures of the patella. A comparison of two methods. J Bone Joint Surg 72:280–282

    Google Scholar 

  4. Hume MC, Wiss DA (1992) Olecranon fractures. A clinical and radiographic comparison of tension band wiring and plate fixation. Clin Orthop 285:229–235

    Google Scholar 

  5. Kiviluoto O, Santavirta S (1978) Fractures of the olecranon. Acta Orthop Scand 49:28–31

    Google Scholar 

  6. Larsen E, Jensen CM (1991) Tension-band wiring of olecranon fractures with nonsliding pins. Report of 20 cases. Acta Orthop Scand 62:360–362

    Google Scholar 

  7. Larsen E, Lyndrup P (1987) Netz or Kirschner pins in the treatment of olecranon fractures? J Trauma 27:664–666

    Google Scholar 

  8. Levack B, Flannagan JP, Hobbs S (1985) Results of surgical treatment of patellar fractures. J Bone Joint Surg [Br] 67:416–419

    Google Scholar 

  9. Low CK, Low BY (1988) Olecranon fracture and tension band wiring. Singapore Med J 29:480–484

    Google Scholar 

  10. Majola A, Vainionpdd S, Vihtonen K, Mero M, Vasenius J, Törmälä P, Rokkanen P (1991) Absorption, biocompatibility, and fixation properties of polylactic acid in bone tissue: an experimental study in rats. Clin Orthop 268:260–269

    Google Scholar 

  11. Matter P, Scharplatz D (1988) Fractures and dislocation of the elbow. In: Chapman MW, Madison M (eds) Operative orthopaedics. Lippincott, Philadelphia, pp 253–262

    Google Scholar 

  12. Partio EK, Hirvensalo E, Böstman O, Pätiälä H, Vainionpää S, Vihtonen R, Helevirta P, Törmälä P, Rokkanen P (1992) Broches et vis biorésorbables: one nouvelle méthode de fixation des fractures de l'olecrâne. Int Orthop 16:250–254

    Google Scholar 

  13. Pihlajamäki H, Böstman O, Hirvensalo E, Törmälä P, Rokkanen P (1994) A biodegradable expansion plug for the fixation of fractures of the medial malleolus. Ann Chir Gynaecol 83:49–54

    Google Scholar 

  14. Vasenius J, Vainionpää S, Vihtonen K, Mero M, Mikkola J, Rokkanen P, Törmälä P (1989) Biodegradable self-reinforced polyglycolide (SR-PGA) composite rods coated with slowly biodegradable polymers for fracture fixation. Strength and strength retention in vitro and vivo. Clin Mater 4:307–317

    Google Scholar 

  15. Wissing JC, Werken C van der (1991) Die Zuggurtungsosteosynthese aus resorbierbarem Material. Unfallchirurg 94:45–46

    Google Scholar 

  16. Wolfgang G, Burke F, Bush D, Parenti J, Perry J, LaFollette B, Lillmars S (1987) Surgical treatment of displaced olecranon fractures by tension band wiring technique. Clin Orthop 224:192–204

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Juutilainen, T., Patiälä, H., Rokkanen, P. et al. Biodegradable wire fixation in olecranon and patella fractures combined with biodegradable screws or plugs and compared with metallic fixation. Arch Orthop Trauma Surg 114, 319–323 (1995). https://doi.org/10.1007/BF00448954

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00448954

Keywords

Navigation