Skip to main content
Log in

Das Prinzip der Messung des luftfreien Körpervolumens mit Hilfe einer Druckdifferenz-Tauchsonde

Measurement of gas free body volume by a diving device

  • Published:
European Journal of Applied Physiology and Occupational Physiology Aims and scope Submit manuscript

Abstract

A device is presented for determination of gas free body volume, by which total body volume as well as lung volume together with intestinal gas can be measured.

The measurement is performed under water. The subject to be measured keeps his head in an airfilled cylinder which allows free breathing during the measurement procedure under water. The subject sits on a seat which is connected with a vertical “probe” that is submerged in a water basin. This “body density probe” carries several measuring rods of different diameter on its upper end, which lead to an increase of buoyancy when sinking deeper into the water after additional weights have been put on the device. These rods lead to new equilibrium states which are also dependent on the compressable gas volume attached to the probe. Three equilibrium states with different added weights give a physical definition of gas free body volume, which can be calculated from a number of accurately measurable single items.

Zusammenfassung

Es wird ein GerÄt zur Bestimmung des luft- und gasfreien Körpervolumens vorgestellt, welches ohne ZusatzgerÄte die Messung des Körpervolumens und zugleich des lufthaltigen Lungenvolumens sowie der Darmgase erlaubt.

Der Kopf des Patienten befindet sich in einem luftgefüllten, nach unten offenen Zylinder, der diesem das freie Atmen wÄhrend der Me\prozedur gestattet. Der Patient sitzt auf einer vertikalen Sonde, die in ein Wasserbecken eingetaucht ist und an ihrem Kopfende Me\stÄbe trÄgt, die bei Zugabe von Zusatzgewichten zusammen mit der Sonde tiefertreten und einen neuen Gleichgewichtszustand bewirken; dieser ist auch von der Grö\e des komprimierbaren Gasvolumens an der Sonde abhÄngig. Drei GleichgewichtszustÄnde ergeben eine physikalische Definition des luftfreien Körpervolumens, das aus einer Serie von exakt me\baren Einzelgrö\en berechnet werden kann.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Literatur

  1. Akers, A., Buskirk, E. R.: An underwater weighing system utilizing force cube transducers. J. appl. Physiol. 26, 649 (1969)

    Google Scholar 

  2. Behnke, H. R., Feen, B. G., Welham, W. C.: Specific gravity of healthy men. J. Amer. med. Ass. 118, 495 (1942)

    Google Scholar 

  3. Bohnenkamp, H., SchmÄh, J.: Untersuchungen zu den Grundlagen des Energie- und Stoffwechsels. IV. Mitteilung. Das Reinvolumen sowie die spezifische Dichte des Menschen und die Bestimmungsweise dieser Grö\en. Pflügers Arch. ges. Physiol. 228, 100 (1931)

    Google Scholar 

  4. Boyd, E.: The specific gravity of the human body. Hum. Biol. 5, 646 (1933)

    Google Scholar 

  5. Gnaediger, R. H., Reineke, E. P., Pearson, A. P., Van Huss, W. D., Wessel, J. A., Montovet, H. J.: Determination of body density by air displacement helium dilution, and underwater weighing. Ann. N.Y. Acad. Sci. 96, 108 (1965)

    Google Scholar 

  6. Goldman, R. F., Buskirk, E. R.: Body volume measurement by underwater weighing: description of a method. Techniques for measuring body composition. Washington, D. C.: Nat. Acad. of Sci. Nat. Res. Council 1961

    Google Scholar 

  7. Jongbloed, J., Noyons, A. K. M.: Die Bestimmung des wahren Volumens und des spezifischen Gewichtes von Menschen mittels LuftdruckverÄnderungen. Pflügers Arch. ges. Physiol. 240, 197–201 (1938)

    Google Scholar 

  8. Katch, F., Michael, E. D., Horvath, St. M.: Estimation of body volume by underwater weighing: description of a simple method. J. appl. Physiol. 23, 811 (1967)

    Google Scholar 

  9. Liuzzo, J. A., Reineke, E. P., Pearson, A. M.: An air displacement method for determining specific gravity. J. Animal. Sci. 17, 513 (1958)

    Google Scholar 

  10. Rathbun, E., Pace, N.: The determination of total body fat by means of the body specific gravity. J. biol. Chem. 158, 667 (1945)

    Google Scholar 

  11. Siri, W. E.: Apparatus for measuring human body volume. Rev. Sci. Ins. 27, 729 (1955)

    Google Scholar 

  12. Walser, M., Stein, S. N.: Determination of specific gravity of intact animal by herlium comparison with water displacement. Proc. Soc. exp. Biol. (N.Y.) 82, 774 (1953)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Diese Arbeit wurde vom österreichischen Fonds für wissenschaftliche Forschung, Projekt Nr. 634 und Projekt Nr. 1661, gefördert.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schmid, P., Schlick, W. Das Prinzip der Messung des luftfreien Körpervolumens mit Hilfe einer Druckdifferenz-Tauchsonde. Europ. J. Appl. Physiol. 35, 59–67 (1976). https://doi.org/10.1007/BF00444657

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00444657

Key words

Schlüsselwörter

Navigation