Skip to main content

Advertisement

Log in

The importance of trochanteric lag screws to achieve primary stability in cementless fixation of the RM hip prosthesis

  • Clinical and Experimental Forum
  • Published:
Archives of orthopaedic and traumatic surgery Aims and scope Submit manuscript

Summary

To allow the bony incorporation of a cementless prosthesis it is important to achieve stability at the time of operation. To neutralize tension and torsional stresses the RM-shaft prosthesis is fixed with two lag screws in the trochanteric part of the femur. By measuring the applied torque intraoperatively we could demonstrate that the threads of the screws found a better grip when inserted from the bone to the prosthesis. Thus, the stronger fixation of the screws enhanced the primary stability of the cementless prosthesis.

Zusammenfassung

Die zementfrei zu implantierende RM-Femurschaftprothese wird nach dem Prinzip der Verklemmung im Femurschaft stabilisiert. Zusätzlich tragen 2 nach dem Zugschraubenprinzip eingebrachte Flügelschrauben im Bereich des Trochanter major zur Rotationsstabilität bei. Intraoperativ mußte oft die Erfahrung gemacht werden, daß das Gewinde dieser Flügelschrauben im häufig osteoporotisch veränderten Trochantermassiv keine ausreichende Verankerung fand. Durch gegenläufiges Einbringen dieser Flügelschrauben wird das Gewinde in dem Werkstoff der Prothesenschraubengänge verankert. Durch these neue Schraubenlage kann im Vergleich zur herkömmlichen Plazierung ein wesentlich höheres Drehmoment zur Fixierung der Schrauben übertragen werden. An 10 Patienten haben wir intraoperativ Messungen mit dem Drehmomentschlüssel durchgeführt und konnten nachweisen, daß die neue Plazierung der Trochanterschrauben die Übertragung einer zwei- bis dreifach größeren Drehmomentkraft zur Fixierung der Schrauben ermöglichte im Vergleich zur herkömmlichen Schraubenlage.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Charnley J (1960) Anchorage of the femoral head prosthesis to the shaft of the femur. J Bone Joint Surg 42:28

    Google Scholar 

  2. Dick W, Jenny H, Morscher E (1984) Revision arthroplasties with the isoelastic total hip replacement. In: Morscher E (ed) The cementless fixation of hip endoprosthesis. Springer, Berlin Heidelberg New York, pp 259–264

    Google Scholar 

  3. Giese H, Schramm W (1984) Nachuntersuchungen von 997 Hüfttotalendoprothesen unter besonderer Berüicksichtigung der Spätergebnisse 9–11 Jahre post operationem. Z Orthop 122:784–789

    Google Scholar 

  4. Mathys R (1973) Stand der Verwendung von Kunststoffen für künstliche Gelenke. Aktuel Traumatol 4:253

    Google Scholar 

  5. Morscher E (1984) Introduction I. In: Morscher E (ed) The cementless fixation of hip endoprostheses. Springer, Berlin Heidelberg New York, pp 1–8

    Google Scholar 

  6. Morscher E (1979) Isoelastische Prothesen. Langenbecks Arch Chir 349:321

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Heitemeyer, U., Hierholzer, G. & Haines, J. The importance of trochanteric lag screws to achieve primary stability in cementless fixation of the RM hip prosthesis. Arch. Orth. Traum. Surg. 106, 120–122 (1987). https://doi.org/10.1007/BF00435425

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00435425

Keywords

Navigation