Skip to main content
Log in

Bestimmung von radioaktivem Kohlenstoff und Wasserstoff in biologischem Material

Determination of radioactive carbon and hydrogen in biological material

  • Originalabhandlungen
  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Zusammenfassung

A simple apparatus is described with which any 14C and/or 3H-containing material up to 350 mg can be combusted and accurately counted. Through the use of nitrogen as flushing gas and the elimination of troublesome elements in the combustion tube, only carbon dioxide and water get absorbed. Thus a quick, constant and reproducible count is made possible with a constant quenching effect, even with low-active products. Inorganic residues are accessible after the combustion and can thus also be analytically determined. Duration of analysis: 12 min. Precision: ±2.5%. Counting yield of 14carbon: 83%, for tritium: 36%.

Zusammenfassung

Es wird eine einfache Apparatur beschrieben, mit der beliebiges 14C- und/oder 3H-haltiges Material bis zu 350 mg Frischgewicht verbrannt und genau ausgezählt werden kann. Durch die Benutzung von Stickstoff als Spülgas und durch die Eliminierung von störenden Elementen im Verbrennungsrohr kommen nur noch Kohlendioxid und Wasser zur Absorption. Daher wird mit einem gleichbleibenden Quencheffekt eine rasche, konstante und reproduzierbare Auszählung auch bei sehr tiefaktiven Produkten ermöglicht. Anorganische Rückstände sind nach der Verbrennung wieder zugänglich und können daher auch analytisch wieder erfaßt werden. Die Analysendauer beträgt 12 min. Mittlerer Fehler ±2,5%. Zählausbeute für Kohlenstoff-14 83%, für Wasserstoff-3 36%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Literatur

  1. Aikman, D. P., Patterson, B. D.: Anal. Biochem. 18, 185 (1967)

    Google Scholar 

  2. Baggett, B., Presson, T. L., Presson, J. B., Coffey, J. C.: Anal. Biochem. 10, 367 (1965)

    Google Scholar 

  3. Bransome, E. D., Jr., Grower, M. F.: Anal. Biochem. 38, 401 (1970)

    Google Scholar 

  4. Dobbs, H. E.: Anal. Chem. 35, 783 (1963)

    Google Scholar 

  5. Frohofer, H.: Diese Z. 253, 97 (1971)

    Google Scholar 

  6. Fuchs, A., de Vries, F. W.: Int. J. Appl. Radiat. Isotopes 23, 361 (1972)

    Google Scholar 

  7. Griffiths, M. H., Mallinson, A.: Anal. Biochem. 22, 465 (1968)

    Google Scholar 

  8. Hunt, L. M., Gilbert, B. N.: Int. J. Appl. Radiat. Isotopes 23, 246 (1972)

    Google Scholar 

  9. Kainz, G., Wachberger, E.: Microchem. J. 10, 114 (1966)

    Google Scholar 

  10. Körbl, J.: Mikrochim. Acta 1956, 1705; vgl. diese Z. 157, 34 (1957)

  11. Lloyd-Jones, C. P.: Analyst 95, 366 (1970)

    Google Scholar 

  12. Parekh, C. K., Eigen, E.: Lipids 3, 225 (1968)

    Google Scholar 

  13. Roberts, W. A.: Lab. Pract. 17, 703 (1968)

    Google Scholar 

  14. Simon, H., Rauschenbach, P.: Int. J. Appl. Radiat. Isotopes 20, 725 (1969)

    Google Scholar 

  15. Smith, R. W., Philips, S. H.: Int. J. Appl. Radiat. Isotopes 20, 553 (1969)

    Google Scholar 

  16. Stevens, A., Estrada, E., Pollay, M., Kaplan, R.: Anal. Biochem. 37, 1 (1970)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Für zahlreiche Anregungen und Diskussionen danke ich Herrn Prof. Dr. Ch. Schlatter, Veterinär-physiologisches Institut der Universität Zürich.

An dieser Stelle möchte ich auch Herrn K. Hochreutener für die elektronische Entwicklung unserer halbautomatischen Apparatur danken. Diese wurde in den mechanischen Werkstätten (Leitung E. Bühler) und der Glasbläserei (Leitung B. Thueler) unseres Instituts gebaut.