Summary
First clinical and radiographic results with a new knee joint prosthesis, implanted without cement, are reported and the characteristics of the implant (dowel fixation and special instrumentation) presented. The first series of 35 joints with a follow-up period of 1–3 years shows excellent results. Radiographically, primary osseous integration cannot be positively identified in all cases, but it could be proved in most instances. Cement-free implantation requires good preoperative bone quality and an operative technique which inserts the implant anatomically. If these two conditions are met, there is every probability of successful implantation. No problems specific to the implant have been encountered.
Similar content being viewed by others
References
Clayton ML, Thompson TR, Mack RP (1986) Correction of alignment deformities during total knee arthroplasties: staged soft-tissue releases. Clin Orthop 202:117–124
Dorr LD, Ranawat CS, Sculco TA, McKaskill B, Orisek BS (1986) Bone graft for tibial defects in total knee arthroplasty. Clin Orthop 205:153–165
Edwards E, Miller J, Chan KH (1988) The effect of postoperative collateral ligament laxity in total knee arthroplasty. Clin Orthop 236:44–51
Friedman RJ, Poss R (1988) Revision total knee arthroplasty in patients with osteoarthritis. Rheum Dis Clin North Am 14:537–544
Graham DR (1988) Polyethylene wear: A cause of failure of the variable-axis total knee prosthesis. A report of three cases. J Bone Joint Surg [Am] 70:943–943
Jenny H, Morscher E, Stuemer J (1986) Die Arthroplastik mit dem “PCA-Kniegelenk” (Porous Coated Anatomic). Z Orthop 124:205–217
Kjaersgaard-Andersen P, Hvid I, Wethelund JO, Sneppen O (1989) Total condylar knee arthroplasty in oestoarthritis. A four- to six-year follow-up evaluation on 103 cases. Clin Orthop 238:167–173
Linder L, Carlsson A, Marsal L, Bjursten LM, Branemark PI (1988) Clinical aspects of osseointegration in joint replacement. A histological study of titanium implants. J Bone Joint Surg [Br] 70:550–555
Puhl W, Trepte CT (1988) Indikation und Ergebnisse achsloser Knieendoprothesen. Z Orthop 126:361–368
Rand JA, Coventry MB (1988) Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop 232:168–173
Ritter MA, Campbell ED (1987) Effect of range of motion on the success of a total knee arthroplasty. J Arthroplasty 212:95–97
Tauber C, Bar-On EB, Ganel A, Malkin C (1986) Total condylar knee prosthesis: A review of 71 operations. Arch Orthop Trauma Surg 104:352–356
Tew M, Forster TW (1987) Effect of knee replacement on flexion deformity. J Bone Joint Surg [Br] 69:395–399
Torisu T, Morita H (1986) Roentgenographic evaluation of geometric total knee arthroplasty with a six-year follow-up period. Clin Orthop 202:125–134
Author information
Authors and Affiliations
Additional information
With the kind support of the Ludwig-Boltzmann-Institut für Rheumatologie und Fokalgeschehen, A-2500 Baden, Austria
Rights and permissions
About this article
Cite this article
Schwägerl, W., Zenz, P. The APS knee joint prosthesis. Arch Orthop Trauma Surg 109, 252–257 (1990). https://doi.org/10.1007/BF00419938
Issue Date:
DOI: https://doi.org/10.1007/BF00419938