High standards of material, design and production are required for alloarthroplastic hip prostheses. Specific problems rise from friction and wear with regard to the fail-proof function and expectation of life. To obtain further information on the complex behaviour of artificial hip joints with close approximation to the human gait a new simulator was designed and built. Selection of a great variety of gait characteristics can readily be accomplished with the new system, which essentially comprises an electronic control device, a hydraulic converter including power supply, the cinetic testing jig and the measuring unit. The specimens are tested in a aqueous immersion of speudo-synovial-liquid or in bovine serum. Time reduction factors up to approx. 15 times normal walking speed can be obtained.

Zusammenfassung

Hohe Anforderungen werden an Material und Konstruktion der für das Hüftgelenk verwendeten Totalendoprothesen gestellt. Besondere Probleme ergeben sich vor allem aus den Reibungs- und Verschleißvorgängen. Da die Entwicklung auf diesem Gebiet sicherlich noch nicht abgeschlossen ist, wurde ein spezieller Gehsimulator entwickelt. Dieser ermöglicht die Untersuchung des Langzeitverhaltens der artikulierenden Prothesengleitoberflächen bei physiologischen Verhältnissen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Boutin, P.: Arthroplasie totale de la hanche par prothése en alumine frittée. Rev. Orthop. 58, 229–256 (1972)

    Google Scholar 

  • Buchholz, H. W., Strickle, E.: Gleitreibverhalten von künstlichen Hüftgelenken mit Kunststoffpfanne. Chirurg 43, 453–458 (1972)

    Google Scholar 

  • Dowson, D., Walker, P. S., Longfield, M. D., Wright, V.: A joint simulating machine for load-bearing joints. Med. & biol. Engng. 8, 37–43 (1970)

    Google Scholar 

  • Duff-Barclay, I., Spillman, D. T.: Lubrication and wear in living and artificial human joints. Proc. Instn. Mech. Engrs. 181, 3J (1966/67)

    Google Scholar 

  • Hoffmann-Daimler, S.: Zur Entwicklung neuer Hüftgelenkprothesen. Med. Orthop. Techn. 93, 31–33 (1973)

    Google Scholar 

  • Limmer, L.: Mathematische Erfassung des Gehvorganges beim Menschen — Entwurf eines Hüftgelenksimulators. Diplomarbeit, Universität Stuttgart 1972

  • Miller, D. A.: Reducing wear in the total hip prosthesis. University of Cincinnati, College of Engineering (1971)

  • Paul, J. P.: Forces transmitted by joints in the human body. Proc. Instn. Mech. Engrs. 181, 3J (1966/67)

    Google Scholar 

  • Pauwels, F.: Der Schenkelhalsbruch. Stuttgart: Enke 1935

    Google Scholar 

  • Rydell, N.: Forces in the hip-joint. In: Biomechanics and related bio-engineering topics, Kenedi, R. M., Ed. Oxford: Pergamon Press 1965

    Google Scholar 

  • Thomas, G., Uhr, H. E.: Experimentelle Untersuchungen zur Leistungsfähigkeit der totalen Hüftgelenkprothese. Z. Orthop. 106, 694–707

  • Walker, P., Dowson, D., Longfield, M., Wright, V.: A joint simulator. In: V. Wright, Lubrication and wear in joints. London: Sector Publishing 1969

    Google Scholar 

  • Walker, P. S., Gold, B. L.: The tribology of all-metal artificial hip joints. Wear 17, 285–299 (1971)

    Google Scholar 

  • Weightman, B., Simon, S., Paul, I., Rose, R., Radin, E.: Lubrication mechanism of hip joint replacement prostheses. J. Lubr. Techn., Transactions of the ASME, 131–135 (1972)

  • Weightman, B. O., Paul, I. L., Rose, R. M., Simon, S. R., Radin, E. L.: A comparative study of total hip replacement prostheses. J. Bimechanics 6, 299–311 (1973)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Herrn Prof. Dr. A. N. Witt zum 60. Geburtstag gewidmet.

Die Arbeit erfolgte durch finanzielle Unterstützung der Stiftung Volkswagenwerk.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ungethüm, M., Hildebrandt, J., Jäger, M. et al. Ein neuer Simulator zur Testung von Totalendoprothesen für das Hüftgelenk. Arch orthop Unfall-Chir 77, 304–314 (1973). https://doi.org/10.1007/BF00418916

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00418916

Navigation