Skip to main content

Advertisement

Log in

Biomechanische Untersuchungen über die maximalen Vorspannkräfte der Knochenschrauben in verschiedenen Knochenabschnitten

Biomechanic researches of maximum initial tension forces of bone screws on various bone sections

  • Published:
Archiv für orthopädische und Unfall-Chirurgie, mit besonderer Berücksichtigung der Frakturenlehre und der orthopädisch-chirurgischen Technik Aims and scope Submit manuscript

Summary

Maximum initial tension forces of spongiosa and/or corticalis screws are measured with piezoelectric gauge discs on fresh human corpse bones. The initial tension forces were depending on thickness of corticalis bones. At location of epiphyse and metaphyse forces were low while at location of shaft they were high. By application of spongiosa and/or corticalis screw the forces were equal high at epiphyse and metaphyse. At location of shaft the corticalis screws attained higher initial tension forces. At the osteosynthesis with plates one can use spongiosa screws as recommended by the swiss AO as well as corticalis screws at epiphyse and metaphyse.

Zusammenfassung

Die maximalen Vorspannkräfte von Spongiosa- und Corticalisschrauben werden mit piezoelektrischen Meßscheiben an frischen menschlichen Leichenknochen gemessen. Die Vorspannkräfte hingen im wesentlichen von der Corticalisdicke der Knochen ab und waren im Bereich der Epiphyse und Metaphyse niedrig, im Schaftbereich hoch. Die Kräfte waren bei Anwendung der Spongiosaschrauben sowie der Corticalisschrauben in der Epiphyse und Metaphyse gleich hoch. Im Schaftbereich erreichten die Corticalisschrauben höhere Vorspannkräfte. In der Epiphyse und Metaphyse können bei der Plattenosteosynthese statt der von der Schweizer AO vorgeschlagenen Spongiosaschrauben genausogut Corticalisschrauben verwendet werden, es sei denn, man würde Spongiosaschrauben mit durchgehendem Gewinde benutzen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Bechtol, C. O., Ferguson, A. B., jr., Laing, P. G.: Metals and engineering in bone and joint surgery. Baltimore: Williams & Wilkins 1959

    Google Scholar 

  • Mittelmeier, H.: Piezoelektrische und spannungsoptische Untersuchungen zur Biomechanik der Schraubenosteosynthese. Z. Orthop. 110, 893–901 (1972)

    Google Scholar 

  • Müller, M. E., Allgöwer, M., Willenegger, H.: Manual der Osteosynthese (AO-Technik). Berlin-Heidelberg-New York: Springer 1969

    Google Scholar 

  • Spycher, F. E.: Untersuchungen mit Drehmomentschlüsseln an verschiedenen Schraubentypen. Inaug.-Diss., Bern 1970

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Diehl, K., Hanser, U., Hort, W. et al. Biomechanische Untersuchungen über die maximalen Vorspannkräfte der Knochenschrauben in verschiedenen Knochenabschnitten. Arch orthop Unfall-Chir 80, 89–94 (1974). https://doi.org/10.1007/BF00416838

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00416838

Navigation