Summary

Fractures of metallic implants are frequently caused by unstable osteosynthesis which facilitates vibrations and inner tensions of the metal. In some unfavourable cases we will have to expect vibration-corrosion. Among about 950 pertrochanteric femoral fractures we could observe 4 nail-fractures, besides 3 plate fractures and 5 screw fractures. Two of about 400 Smith-Peterson nails implanted for arthrodesis of the hip, broke. Three of 400 Küntscher nails and two of 150 Rush-pins broke. In nearly all of these cases the fracture of the metal could have been avoided by a better operation technique, partially by application of AO plates in pertrochanteric fractures that have no weak point in the area of the fracture partially by better reposition of the bone fracture. Working with the Küntscher nail the bone marrow space should be drilled to such a width that the nail fills completely the inner space up to the corticalis Rush-pins are generally to thin for fixation of greater bones. If the metallic fixation of fractures is only unstable we must use a cast fixation externally in addition.

Résumé

Les fractures des metaux utilisés pour fixation interne d'une fracture osseuse, ont leur origine frequemment dans une ostéosynthèse non stabilisante. Dans ces cas les metaux devont subir des vibrations et des tensions internes, terminant parfois dans une corrosions par vibration. Nous trouvâmes 4 clous-Böhler fracturés en 950 operations pour une fracture transcondylaire du femur. Trois clous de Küntscher de 400 et deux Rush-pins en 150 étaient fracturés. Presque dans tous les cas une meilleure technique operatoire aurait empéché ces malheurs. Si l'on peut pas stabiliser une fracture osseuse par des metaux interne il était préférable d'appliquer une fixation externe quelquonque.

Zusammenfassung

Die Ursache der Brüche metallischer Implantate liegt sehr häufig in einer instabilen Osteosynthese und der dadurch ermöglichten Schwingung und Vorspannung des Metalls. Es kommt daher in einigen ungünstigen Fällen zur Schwingungsrißkorrosion. Unter etwa 950 pertrochanteren Oberschenkelfrakturen fanden wir 4 Nagelfrakturen, außerdem 3 Plattenbrüche und 5 Schraubenbrüche. Bei etwa 400 Nagelungen mit dem Smith-Peterson-Nagel wurden 2 Nagelbrüche nach Hüftgelenksarthrodese festgestellt. Unter etwa 400 Küntscher-Nägeln brachen 3, und von ca. 150 Rushpins brachen 2. In fast allen Fällen ließe sich eine Metallfrakturierung durch eine bessere Operationstechnik vermeiden, sei es, daß für die pertrochanteren Brüche AO-Platten verwendet werden, die im Bereich der Fraktur keine Kerbstelle besitzen, sei es, daß sorgfältiger reponiert wird. Bei der Küntscher-Nagelung muß auf eine solche Dicke aufgebohrt werden, daß ein entsprechender Nagel den Markraum innen im Bruchbereich fest ausfüllt. Rushpins sind zur Fixierung großer Röhrenknochen generell zu dünn. Ist die Fraktur nur instabil zu versorgen, so wird eine zusätzliche äußere Gipsfixierung notwendig.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Bauder, K.: Marknagelverbiegungen. Chir. Praxis 12, 591–595 (1968).

    Google Scholar 

  • Böhler, L.: Technik der Knochenbruchbehandlung, Bd. III, S. 105. Wien: Maudrich 1956.

    Google Scholar 

  • Bowden, F. P., I. B. P. Williamson, and P. G. Laing: Metallic transfer in screwing and its significance in bone surgery. Nature (Lond.) 173, 520–522 (1954).

    Google Scholar 

  • Bürkle de la Camp, H.: Fehler und Gefahren in der Knochen- und Gelenkchirurgie. Langenbecks Arch. klin. Chir. 289, 463–475 (1958).

    Google Scholar 

  • Clarke, E., and J. Hickman: An investigation into the correlation between the electrical potentials of metals and their behaviour in biological fluids. J. Bone Jt Surg. 35-B, 467–473 (1953).

    Google Scholar 

  • Cohen, J.: Corrosion-testing for orthopedic implants. J. Bone Jt Surg. 44-A, 307–316 (1962).

    Google Scholar 

  • Contzen, H.: Grundlagen der Alloplastik mit Metallen und Kunststoffen. Stuttgart: Thieme 1967.

    Google Scholar 

  • Dürr, W., H. W. Bumm u. R. Helms: Über Allenthesen zur operativen Behandlung von Frakturen im Bereiche des Trochantermassivs. Chirurg 36, 165–175 (1966).

    Google Scholar 

  • Emneus, H., and U. Stenram: Reaction to alloys used in osteosynthesis. Acta orthop. scand. 24, 315–330 (1960).

    Google Scholar 

  • Ferguson, A. B., P. G. Laing, and E. S. Hodge: The ionization of metal implants in living tissues. J. Bone Jt Surg. 42-A, 77–90 (1960).

    Google Scholar 

  • Fischer, S., u. H. Zitter: Verhalten von chemisch beständigen Stählen im menschlichen Körper. Werkstoffe und Korrosion 20, 753–758 (1963).

    Google Scholar 

  • Fischer-Wasels, J., u. H. B. Schünemann: Zur Frage von Marknagelbrüchen. Arch. orthop. Unfall-Chir. 46, 207–228 (1953).

    Google Scholar 

  • Gough, H. J. J.: Inst. Met. 49, 17 (1932); zit. n. H. Spähn.

    Google Scholar 

  • Häbler, C.: Die Marknagelung nach Küntscher. Berlin-München: Urban & Schwarzenberg 1953.

    Google Scholar 

  • Hermann, L.: Nagelbruch und Verbiegung als Spätkomplikation nach Marknagelung. Zbl. Chir. 85, 354–361 (1960).

    Google Scholar 

  • Kemlein, W.: Extraktionsgerät für Schenkelhalsnagelbruchstücke mit V-förmigem Querschnitt. Chirurg 38, 385 (1968).

    Google Scholar 

  • Kirsch, J.: Die Stabilität des Küntscher-Nagels. Mschr. Unfallheilk. 62, 143–147 (1959).

    Google Scholar 

  • Koch, W.: Erfahrungen bei Anwendung der Spreizschraube zur Fixation von Olecranonbrüchen. Zbl. Chir. 93, 195–196 (1968).

    Google Scholar 

  • Küntscher, G.: Praxis der Marknagelung. Wien: Maudrich 1959.

    Google Scholar 

  • —— Die Osteosynthese. Zbl. Chir. 85, 828–840 (1960).

    Google Scholar 

  • Letiz, G.: Typische Komplikationen nach Osteosynthesen und ihre mechanischen Ursachen. Arch. orthop. Unfall-Chir. 64, 285–297 (1968).

    Google Scholar 

  • Longinow, A. W.: Stress corrosion testing of alloys. Materials protection 8, 33–39 (1966).

    Google Scholar 

  • Seyfarth, H.: Beitrag zur Anwendung von Metallen in der plastischen Chirurgie. Arch. orthop. Unfall-Chir. 47, 656–663 (1955).

    Google Scholar 

  • Spähn, H.: Zur Schwingungsrißkorrosion metallischer Werkstoffe. Metalloberfläche 16, 197–202, 233–239, 267–273, 299–307, 335–340, 369–373 (1967); 17, 1–9 (1968).

    Google Scholar 

  • Täger, K. H.: Materialprüfung für Metalle in der Orthopädie und Chirurgie. Chirurg 33, 129–131 (1962).

    Google Scholar 

  • Werhahn, O.: Beitrag zur Spannungsentwicklung in Knotenpunkten geschweißter Fachwerkbrücken. Dissertation Hannover 1955.

    Google Scholar 

  • Wright, J. K., and J. H. Axon: Electrolysis and stainless steel in bone. J. Bone Jt Surg. 38, 745–753 (1956).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

v. Elmendorff, H.F., Simmert, H. & Hupfauer, W. Über Brüche von metallischen Implantaten. Arch orthop Unfall-Chir 67, 141–154 (1969). https://doi.org/10.1007/BF00416834

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00416834

Navigation