Skip to main content
Log in

Summary

Based on a new method of measuring episcleral venous pressure (EVP), i.e., using the ‘air-jet principle’ of Krakau et al. (1973), pseudofacility was determined in 20 human eyes. According to Bárány's formula, a mean value of 23.3 % of the total facility was found, and a mean value of 16.9 % according to Goldmann's formula.

Zusammenfassung

Bei 20 gesunden Probanden beiderlei Geschlechts mit einem Durchschnittsalter von 28 Jahren wurde die Pseudofacility nach den von Bárány und Goldmann vorgeschlagenen Verfahren ermittelt. Die Anwendung der Bárány'schen Formel ergab 23,3 % Anteil der Pseudofacility an der Gesamtfacility, die der Goldmann'schen Formel 16,9 %.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bárány, E.: A mathematical formulation of intraocular pressure as dependent of secretion, ultrafiltration, bulk outflow and reabsorption of fluid. Invest. Ophthalmol. 2, 584–590 (1963)

    Google Scholar 

  • Brubaker, R.F., Kupfer, C.: Determination of pseudofacility in the eye of the rhesus monkey. Arch. Ophthalmol. 75, 693–697 (1966)

    Google Scholar 

  • Goldmann, H.: In: Glaucoma Tutzing Symposion 1966, W. Leydhecker ed., pp. 40–45. Basel-New York: Karger 1967

    Google Scholar 

  • Goldmann, H.: On pseudofacility. Bibl. Ophthalmol., No. 76, 1–14 (1968)

    Google Scholar 

  • Kaskel, D., Müller-Breitenkamp, R., Wilmans, L, Rudolf, H., lessen, K.: Augeninnendruck, Episkleralvenendruck und Blutdruck bei Änderung der Körperlage. Albrecht von Graefes Arch. Klin. Ophthalmol. (in press 1978)

  • Krakau, C.E., Widakowich, J., Wilke, K.: Measurements of the episcleral venous pressure by means of an air jet. Acta Ophthalmol. (Kbh.) 51(2), 185–196 (1973)

    Google Scholar 

  • Kupfer, C.: Pseudofacility in untreated glaucoma. Doc. Ophthalmol. 26, 309–312 (1969)

    Google Scholar 

  • Kupfer, C.: Pseudofacility in the human eye. Trans. Am. Ophthalmol. Soc. 69, 383–396 (1971)

    Google Scholar 

  • Kupfer, C., Ross, K.: Studies of aqueous humor dynamics in man. I. Measurements in young normal subjects. Invest. Ophthalmol. 10(7), 518–522 (1971)

    Google Scholar 

  • Kupfer, C., Sanderson, P.: Determination of pseudofacility in the eye of man. Arch. Ophthalmol. 80, 194–196 (1968)

    Google Scholar 

  • Todd, R., Woodhouse, D.: Pseudofacility: a method of measurement using suction-cup tonography. Exp. Eye Res. 17(2), 173–182 (1973)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kaskel, D., Arens, E. Determination of pseudofacility in man. Albrecht von Graefes Arch. Klin. Ophthalmol. 210, 187–192 (1979). https://doi.org/10.1007/BF00414568

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00414568

Keywords

Navigation