Skip to main content
Log in

Zur Auswertung des Elektrookulogramms

Interpretation of the Electroculogram

  • Published:
Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie Aims and scope Submit manuscript

Summary

279 electroculograms (12 minutes in the dark and 10 minutes in the bright) of eye-healthy subjects were evaluated (mean, standard error of mean; differences were t-tested, significances given by P-values): The mean electrooculogram is higher in femal than in male subjects. Also it is higher in 17–18 aged than in 26 aged subjects.

The evaluation of correlations between the starting value of the electrooculogram, the dark through, the light peak, the dark descent, the light ascent from 559 electrooculograms let conclude: Absolute values are best for the characterization of the electrooculogram.

Zusammenfassung

Die Auswertung von 279 bzw. 559 Elektrookulogrammen von augengesunden Versuchspersonen (Berechnung der Mittelwerte mit den Standardabweichungen und Berechnung der Korrelationen zwischen den Ausgangswerten, den Dunkeltalwerten, den Hellgipfelwerten, den Dunkelabfällen und den Hellanstiegen) ergab:

  1. 1.

    Die Streuung der Einzelwerte um den Mittelwert ist sehr groß (N=279); die Variationskoeffizienten liegen etwa um 30%.

  2. 2.

    Das Mittelwert-Elektrookulogramm liegt insgesamt für die weiblichen Versuchspersonen (N=184) signifikant höher als für die männlichen Versuchspersonen (N=95).

  3. 3.

    Das Mittelwert-Elektrookulogramm der 17–18jährigen Versuchspersonen (N=22) liegt insgesamt signifikant höher als das der 26jährigen (N=58).

  4. 4.

    Nach den Ergebnissen der Korrelationsberechnungen (N=559) eignen sich zur Beurteilung des Elektrookulogramms am besten die absoluten Werte: für das normale Bestandspotential der Ausgangswert des EOG, für die Dunkel- und Hellreaktion des Bestandspotentials das Dunkeltal bzw. der Hellgipfel oder der Dunkelabfall bzw. der Hellanstieg (gemessen vom Ausgangswert oder vom Dunkeltal) des Elektrookulogramms.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Arden, G. B., Barrada, A., Kelsey, J. H.: New clinical test of retinal function based upon the standing potential of the eye. Brit. J. Ophthal. 46, 449–467 (1962)

    Google Scholar 

  • Arden, G. B., Kelsey, J. H.: Changes produced by light in the standing potential of the human eye. J. Physiol. (Lond.) 161, 189–204 (1962)

    Google Scholar 

  • Davis, J. R., Shackel, B.: Changes in the electrooculogram potential level. Brit. J. Ophthal. 44, 606–618 (1960)

    Google Scholar 

  • Fenn, W. O., Hursh, J. B.: Movements of the eyes when the lids are closed. Amer. J. Physiol. 118, 8–14 (1937)

    Google Scholar 

  • Francois, J., de Rouck, A., Fernandez-Sasso, D.: Electroretinography and electroculography in diseases of the posterior pole of the eye. Advanc. Ophthal. 21, 132–163 (1969)

    Google Scholar 

  • Francois, J., Szmigielski, M., Verriest, G., de Rouck, A.: The influence of changes in illumination on the standing potential of the human eye. Ophthalmologica (Basel) 150, 83–91 (1965)

    Google Scholar 

  • Francois, J., Verriest, G., de Rouck, A.: Electrooculography as a functional test in pathological conditions of the fundus. II. Base-value and drop during dark adaptation. Brit. J. Ophthal. 40, 305–312 (1956)

    Google Scholar 

  • Gliem, H.: Das Elektrookulogramm. Abhandlungen aus dem Gebiet der Augenheilkunde, Bd. 40. Leipzig: Thieme 1971

    Google Scholar 

  • Haase, E., Müller, W.: Meßbare Beeinflussung des EOG durch Zigarettenrauchen? Klin. Mbl. Augenheilk. 158, 677–681 (1971)

    Google Scholar 

  • Homer, L. D., Kolder, H.: Mathematical model of oscillations in the human corneo-retinal potential. Pflügers Arch. ges. Physiol. 287, 197–202 (1966)

    Google Scholar 

  • Janzen, H., Pohl, W.: Der Einfluß der dargebotenen Lichtintensität auf die Hellphase des Elektrooculogrammes (EOG). Inaugural-Dissertation, Erfurt 1969

  • Kikawada, N.: Variations in the corneo-retinal standing potential of the vertebrate eye during light and dark adaptations. Jap. J. Physiol. 18, 687–702 (1968)

    Google Scholar 

  • Kolder, H.: Spontane und experimentelle Änderungen des Bestandspotentials des menschlichen Auges. Pflügers Arch. ges. Physiol. 268, 258–272 (1959)

    Google Scholar 

  • Kolder, H., Brecher, G. A.: Fast oscillations of the corneoretinal potential in man. Arch. Ophthal. 75, 232–237 (1966)

    Google Scholar 

  • Körber, H., Körber, H.-J.: Der Einfluß der Praeadaptation auf den Potentialverlauf des Elektrookulogramms. Inaugural-Dissertation, Erfurt 1969

  • Kris, C.: Corneo-fundal potential variations during light and dark adaptation. Nature (Lond.) 182, 1027–1028 (1958)

    Google Scholar 

  • Miles, W. R.: The steady polarity potential of the human eye. Proc. nat. Acad. Sci. (Wash.) 25, 25–36 (1939a)

    Google Scholar 

  • Miles, W. R.: Reliability of measurements of the steady polarity potential of the eye. Proc. nat. Acad. Sci. (Wash.) 25, 128–137 (1939b)

    Google Scholar 

  • Mirsch, E., Thieme, G.: Das Verhalten des Elektro-Okulogramms bei hohen Lichtintensitäten in der Hellphase. Inaugural-Dissertation, Erfurt 1969

  • Müller, W., Haase, E.: Inter- und intraindividuelle Streuung im EOG. Albrecht v. Graefes Arch. klin. exp. Ophthal. 181, 71–78 (1970)

    Google Scholar 

  • Müller, W., Haase, E., Wedekind, K., Niedlich, R.: Das Verhalten des EOG nach Kaffeegenuß. Klin. Mbl. Augenheilk. 162, 379–383 (1973)

    Google Scholar 

  • North, A. W.: Accuracy and precision of electrooculographic recording. Invest. Ophthal. 4, 343–348 (1965)

    Google Scholar 

  • Reeser, F., Weinstein, G. W., Feiock, K. B., Oser, R. S.: Electro-oculography as a test of retinal function. The normal and supernormal eog. Amer. J. Ophthal. 70, 505–514 (1970)

    Google Scholar 

  • Schmidt, B.: Die Elektrookulographie als klinische Untersuchungsmethode. Klin. Mbl. Augenheilk. 151, 249–258 (1967)

    Google Scholar 

  • Schmidt, B.: Einfluß des Zigarettenrauchens auf das EOG. Klin. Mbl. Augenheilk. 156, 523–531 (1970)

    Google Scholar 

  • Shackel, B.: Pilot study in electro-oculography. Brit. J. Ophthal. 44, 89–113 (1960)

    Google Scholar 

  • Shackel, B., Davis, J. R.: A second survey with electro-oculography. Brit. J. Ophthal. 44, 337–346 (1960)

    Google Scholar 

  • Walter, R.: Das Elektrookulogramm in Abhängigkeit von Alter und Geschlecht. Inaugural-Dissertation, Erfurt 1969

Download references

Author information

Authors and Affiliations

Authors

Additional information

Für die Durchführung der Berechnungen danke ich Herrn Dietmar Goldammer von der Arbeitsgruppe Elektronische Datenverarbeitung, Abteilung C 8205 der Medizinischen Akademie Erfurt.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Höhne, W. Zur Auswertung des Elektrookulogramms. Albrecht von Graefes Arch. Klin. Ophthalmol. 192, 35–47 (1974). https://doi.org/10.1007/BF00411318

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00411318

Navigation