Sensitive three-parameter flow-cytometric detection of abnormal cells in human cervical cancers: A pilot study

  • Original Papers
  • Clinical Oncology or Epidemiology
  • Published:
Journal of Cancer Research and Clinical Oncology Aims and scope Submit manuscript

Summary

The cell volume, the DNA, and the carcino-embryonic (CEA) or epithelial-membrane (EMA) antigen of formaldehyde-fixed human cervical cells from 21 malignant cervix tumors and 11 normal patients were measured simultaneously with a Fluvo-Metricell flow cytometer. The simulataneous cell volume and DNA measurement provided the distinction of morphologically intact cells from cell debris, the determination of the cell cycle phase combined with the detection of aneuploid cells, and the distiction of inflammatory cells from parenchymal and tumor cells. Malignant samples were recognized because they contained more than 0.5% CEA positive cells which were of intermediate size. CEA and EMA expression in the malignant samples was not linked. The false positive rate in a total of 32 samples was 6.3% when the sum of CEA and EMA positive cells of each cell sample was calculated. No false negative malignant sample was observed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Abmayr W (1979) Progress report of the TUDAB projekt for automated cancer cell detection.J Histochem Cytochem 27:604–612

    Google Scholar 

  • Al I, Ploem JS (1979) Detection of suspicious cells and rejection of artefacts in cervical cytology. J Histochem Cytochem 27:629–634

    Google Scholar 

  • Barrett DL, Jensen RH, King EB, Dean PhN, Mayall BH (1979) Flow cytometry of human gynecologic specimens using log chromomycin A3 fluorescence and log 90 light scatter. J Histochem Cytochem 27:573–578

    Google Scholar 

  • Cambier JL, Wheeless LL (1979) Predicted performance of single versus multiple slit flow systems. J Histochem Cytochem 27:335–341

    Google Scholar 

  • Crissman HA, Oka, MS, Steinkamp JA (1976) Rapid staining method for analysis of dexyribonucleic acid and protein in mammalian cells. J Histochem Cytochem 24:64–71

    Google Scholar 

  • Daxenbichler G, Grill HJ, Domanig R, Moser E, Dapunt (1980) Receptor binding of fluorescein-labeled steroids. J Steriod Biochem 13:489–493

    Google Scholar 

  • Dolbeare FA, Smith RE (1979) Flow cytoenzymology. In: Melamed MR, Mullaney PF, Mendelsohn ML (eds) Rapid enzyme analysis of single cells. Flow cytometry and sorting. J. Wiley, New York, pp 317–333

    Google Scholar 

  • Goerttler K, Stöhr M (1979) Quantitative cytology of the positive region in flow sorted vaginal smears. J Histochem Cytochem 27:567–572

    Google Scholar 

  • Göhde W, Schumann J, Otto F, Hacker U, Zante J, Hansen P, Büchner Th, Schwale M, Barranco S (1980) DNA measurements on sperm and blood cells of gentically normal and abnormal humans. In: Laerum OD, Lindmo T, Thorud E (eds) Flow cytometry IV. Universitetsforlaget, Oslo, pp 273–276

    Google Scholar 

  • Habbersett MC, Shapiro M, Bunnag B, Nishiya I, Herman Ch (1979) Quantitative analysis of flow microfluorimetric data for screening of gynecologic cytology specimens. J Histochem Cytochem 27:536–544

    Google Scholar 

  • Heyderman E, Steele K, Ormerod MG (1979) A new antigen on the epithelial membrane: Its immunoperoxidase localisation in normal and neoplastic tissue. J Clin Pathol 32:35–39

    Google Scholar 

  • Kachel V, Glossner E, Kordwig E, Ruhenstroth-Bauer G (1977) Fluvo-Metricell, a combined cell volume and cell fluorescence analyzer. J Histochem Cytochem 25:804–812

    Google Scholar 

  • Kachel V, Benker G, Lichtnau K, Valet G, Glossner E (1979) Fast imaging in flow: A means of combining flor cytometry and image analysis. J Histochem Cytochem 27:335–341

    Google Scholar 

  • Kachel V, Benker G Weiss W, Glossner E, Valet G, Ahrens O (1980) Problems of fast imaging in flow. Laerum JF Lindmo T, Thorud E (eds) Flow cytometry IV. Universitetsforlaget, Oslo pp 49–55

    Google Scholar 

  • Kay DB, Cambier JL, Wheeless LL (1979) Imaging in flow. J Histochem Cytochem 27:329–334

    Google Scholar 

  • Leary JF, Todd P, Ross GS, Mortel R, Fleagle GS (1979) The use of percent volume analysis in Coulter sizing of cells in gynecologic cytopathologic cell suspensions.Anal Quant Cytol 1:228–232

    Google Scholar 

  • Malin-Berdel J, Valet G (1980) Flow cytometric determination of esterase and phosphatase activities and kinetics in hematopoietic cells with fluorogenic substrates. Cytometry 1:222–228

    Google Scholar 

  • Nenci I, Dandliker WB, Meyers CY, Marchetti E, Marzola A, Fabris G (1980) Estrogen receptor biochemistry by fluorescent estrogen. J Histochem Cytochem 28:1081–1088

    Google Scholar 

  • Scheiffarth OF, Valet G, Dvorak R, Baur S, Kachel V, Zander J, Ruhenstroth-Bauer G (1979) Flowcytometric characterisation of tumor-associated changes in gynecologi malignancies. Peeters H (ed) Separation of cells and subcellular elements. Pergamon Press, Oxford, pp 11–16

    Google Scholar 

  • Sloane JP, Ormerod MG (1981) Distribution of epithelial membrane antigen in normal and neoplastic tissues and its value in diagnostic tumor pathology. Cancer 47:1786–1795

    Google Scholar 

  • Soost HJ, Baur S (1980) Gynäkologische Zytodiagnostik, 4th edn. Thieme, Stuttgart

    Google Scholar 

  • Sprenger E, Witte S (1979) The diagnostic significance of nuclear deoxyribonucleic acid measured in automated cytology. J Histochem Cytochem 27:520–521

    Google Scholar 

  • Stöhr M, Futterman G (1979) Visualisation of multidimensional spectra in flow cytometry. J Histochem Cytochem 27:560–563

    Google Scholar 

  • Valet G, Fischer B, Sundergeld A, Hanser G, Kachel V, Ruhenstroth-Bauer G (1979) Simultaneous flow-cytometric DNA and volume measurements of bone marrow cells as sensitive indicator of abnormal proliferation patterns in rat leukemias. J Histochem Cytochem 27:398–403

    Google Scholar 

  • Valet G (1980) Graphical representation of three-parameter flow-cytometric histograms by a newly developed FORTRAN IV computer program. Laerum OD, Lindmo T Thorud E (eds) Flow cytometry IV. Universitetsforlaget, Oslo, pp 125–129

    Google Scholar 

  • Watson JV (1980) Enzyme kinetic studies in cell populations using fluorogenic substrates and flowcytometric techniques. Cytometry 1:143–151

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Valet, G., Ormerod, M.G., Warnecke, H.H. et al. Sensitive three-parameter flow-cytometric detection of abnormal cells in human cervical cancers: A pilot study. J Cancer Res Clin Oncol 102, 177–184 (1981). https://doi.org/10.1007/BF00410669

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00410669

Key words

Navigation