Skip to main content
Log in

Flow microfluorometric DNA content measurements of tissue culture cells and peripheral lymphocytes

  • Original Investigations
  • Published:
Human Genetics Aims and scope Submit manuscript

Summary

The difference in DNA content of peripheral lymphocytes from normal males, normal females, and an individual with a 48 (xxxy) chromosome constitution was determined by rapid flow microfluorometric techniques. A similar comparison was performed using tissue culture fibroblasts derived from an individual with a 49 (xxxxy) chromosome constitution and WI-38 cells as a normal control. Less than 60 min were required to isolate the lymphocytes, to stain the cells fluorescently, and to measure the increased DNA content. The measured increase in DNA content is consistent with chromosome DNA analyses and chromosome length measurements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Böyum, A. J.: A one-stage procedure for isolation of granulocytes and lymphocytes from human blood. General sedimentation properties of white blood cells in a 1 g gravity field. Scan. J. Clin. Lab. Invest. 21, Suppl. 97, 51–76 (1968)

    Google Scholar 

  • Callis, J., Hoehn, H.: Flow-fluorometric diagnosis of euploid and aneuploid human lymphocytes. Am. J. Hum. Genet. 28, 577–584 (1976)

    Google Scholar 

  • Cram, L. S., Gomez, E. R., Thoen, C. O., Forslund, J. C., Jett, J. H.: Flow microfluorometric quantitation of the blastogenic response of lymphocytes. J. Histochem. Cytochem. 24, 383–387 (1976)

    Google Scholar 

  • Crissman, H. A., Tobey, R. A.: Cell-cycle analysis in 20 minutes. Science 184, 1297–1298 (1974)

    Google Scholar 

  • Holm, D. M., Cram, L. S.: An improved flow microfluorometer for rapid measurement of cell fluorescence. Exp. Cell Res. 80, 105–110 (1973)

    Google Scholar 

  • Horan, P. K., Jett, J. H., Romero, A., Lehman, J. M.: Flow microfluorometry analysis of DNA content in Chinese hamster cells following infection with Simian virus 40. Int. J. Cancer 14, 514–521 (1974)

    Google Scholar 

  • Kraemer, P. M., Deaven, L. L., Crissman, H. A., Van Dilla, M. a.: DNA constancy despite variability in chromosome number. Adv. Cell. Mol. Biol. 2, 47–108 (1972)

    Google Scholar 

  • Krishan, A.: Rapid flow cytofluorometric analysis of mammalian cell cycle by propidium iodide staining. J. Cell Biol. 66, 188–193 (1975)

    Google Scholar 

  • Mendelsohn, M. M., Mayall, B. H., Bogart, E., Moore, D. H., Perry, B. H.: DNA content and DNA-based centromeric index of the 24 human chromosomes. Science 179, 1126–1129 (1973)

    Google Scholar 

  • Penrose, L. S.: A note on the mean measurements of human chromosomes. Ann. Hum. Genet. 28, 195–196 (1964)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Cram, L.S., Lehman, J.M. Flow microfluorometric DNA content measurements of tissue culture cells and peripheral lymphocytes. Hum Genet 37, 201–206 (1977). https://doi.org/10.1007/BF00393583

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00393583

Keywords

Navigation