Summary
Different groups have observed and reported deviating tissue reactions for the same material for bone replacement: for the “bioinert” Al2O3-ceramic close bone contact is mentioned, others report about a soft tissue layer adjacent to the implant; for the “bioactive” glass ceramic interfaces capable to transmit considerable shear forces are described, others found no interface bonding.—The analysis of the results of animal experiments and the evaluation of clinical follow-up studies show that these discrepancies had been caused by the differences of the biomechanical situations in the examined interfaces. It is pointed out that the negligence or not mentioning of the load pattern at the site of examination can lead to misinterpretations about the possibilities and limits of applicability of biomaterials.
Zusammenfassung
Am gleichen Knochenersatzmaterial haben verschiedene Arbeitsgruppen unterschiedliche Gewebereaktionen beobachtet und beschrieben: Bei der „bioinerten” Al2O3-Keramik werden einmal enger Knochenkontakt, von anderen die Existenz eines Weichgewebeinterponates erwähnt; für “bioaktive” Glaskeramiken werden einmal Scherkräfte von beträchtlicher Größe übertragende Grenzflächen beschrieben, andere fanden keine Grenzflächenhaftung. — Die Analysen tierexperimenteller Ergebnisse und die Auswertungen klinischer Nachsorgeuntersuchungen zeigen, daß these Diskrepanzen durch die Unterschiede in der biomechanischen Situation der jeweils untersuchten Grenzflächen hervorgerufen worden Bind. Es wird darauf hingewiesen, daß die Nichtbeachtung oder die Nichtnennung des Belastungs zustandes am Ort der Probeentnahme zu Fehlbeurteilungen über die Anwendungsmöglichkeiten und -grenzen von Biomaterialien führt.
Similar content being viewed by others
Literatur
Andrian-Werburg, H. v., Griss, P., Krempien, B., Heimke, G.: Klinische Problematik und experimentelle morphologische Befunde bei der Verwendung keramischer Werkstoffe in der Orthopädie und Unfallchirurgie. Z. Orthop. 111, 577–579 (1973)
Beckham, C. A., Greenlee, T. C., Crebo Jr., A. R.: Bone Formation at a Ceramic Implant Interface. Calc. Tiss. Res. 8, 165–171 (1971)
Blencke, B., Brömer, H., Deutscher, K.: Glaskeramik-ein neuer, bioaktiver Implantatwerkstoff. Med. Orthop. Technik 95, 144–148 (1975)
Christel, P., Derethe, P., Sedel, L.: A Simulator to Study on Fresh Cadaver the Mechanical Behaviour of the Normal and Prosthetic Hip. First European Conference on Evaluation of Biomaterials, Strassburg, Vortrag I. 3. 2., 25.–28. Sept. 1977
Deutscher, K., Brömer, H., Blencke, B., Pfeil, H., Strunz, V.: Properties of a Bio-Active Implant Material. Sci. Ceram. 9, 219–225 (1977)
Ducheyne, P., DeMeester, P., Aernoudt, E., Martens, M., Mullier, J. C.: Influence of a Functional Dynamic Loading on Bone Ingrowth into Surface Pores of Orthopedic Implants. J. Biomed. Mater. Res. 11, 811–838 (1977)
Dunn, E. J., White, E. W.: Bone Ingrowth in Porous Implants. In: Biocompatibility of Implant Materials (Ed. D. Williams), p. 80–84. London: Sector Publishing Ltd. 1976
Geduldig, D., Dörre, E., Happel, M., Lade, R., Prüssner, P., Willert, H.-G., Zichner, L.: Welche Aussicht hat die Biokeramik als Implantatmaterial in der Orthopädie? Med. Orthop. Technik 95, 138–143 (1975)
Geduldig, D., Lade, R., Prüssner, P., Willert, H.-G., Zichner, L., Dörre, E.: Experimental Investigations of Dense Alumina Ceramic for Hip and Knee Joint Replacements. In: Engineering in Medicine. 2. Artificial Hip and Knee Joint Technology (Ed. M. Schaldach, D. Hohmann), p. 434–445. Berlin-Heidelberg-New York: Springer 1976
Griss, P., Krempien, B., Andrian-Werburg, H. v., Heimke, G., Fleiner, R.: Experimentelle Untersuchung zur Gewebsverträglichkeit oxidkeramischer (A1203) Abriebteilchen. Arch. orthop. Unfall-Chir. 76, 270–279 (1973 a)
Griss, P., Andrian-Werburg, H. v., Krempien, B., Heimke, G.: Biological Activity and Histocompatibility of Dense Al2O3/MgO Ceramic Implants in Rats. J. Biomed. Mater. Res. Symposium No. 4, 453–462 (1973b)
Griss, P., Heimke, G., Krempien, B., Silber, R., Haehner, H., Merkle, B.: Erste Erfahrungen mit der Keramik-Metallverbundprothese. Med. Orthop. Technik 95, 159–162 (1975a)
Griss, P., Heimke, G., Andrian-Werburg, H. v., Krempien, B., Reipa, S., Lauterbach, H. J., Hartung, H. J.: Morphological and Biomechanical Aspects of Al2O3 Ceramic Joint Replacement. Experimental Results and Design Considerations for Human Endoprotheses. J. Biomed. Mater. Res. Symposium No. 6, 177–188 (1975b)
Griss, P., Heimke, G., Andrian-Werburg, H. v.: Die Aluminiumoxidkeramik-Metall-Verbundprothese. Fine neue Hüftge-lenktotalendoprothese zur teilweise zementfreien Implantation. Arch. orthop. Unfall-Chir. 81, 259–266 (1975c)
Griss, P., Heimke, G., Krempien, B., Jentschura, G.: Ceramic Hip Joint Replacement-Experimental Results and Early Clinical Experience. In: Engineering in Medicine, Vol. 2, Advances in Artificial Hip and Knee Joint Technology, p. 446–455 (Ed. M. Schaldach, D. Hohmann). BerlinHeidelberg-New York: Springer 1976a
Griss, P., Heimke, G., Krempien, D., Hartung, H. J., Reipa, S., Lauterbach, H. J., Diehm, Th.: Experimental Ceramic Joint Replacement. In: Biocompatibility of Implant Materials (Ed. D. Williams), p. 70–79. London: Sector Publishing Ltd. 1976b
Griss, P., Greenspan, D. C., Heimke, G., Krempien, B., Buchinger, R., Hench, L. L., Jentschura, G.: Evaluation of a Bioglas-Coated Al2O3 Total Hip Prosthesis in Sheep. J. Biomed. Mater. Res. Symposium No. 7, 511–518 (1976c)
Griss, P., Werner, E., Buchinger, R., Heimke, G.: Die Mannheimer Oxidkeramik-Metall-Verbundendoprothesen. Arch. orthop. Unfall-Chir. 87, 73–84 (1977a)
Griss, P., Werner, E., Heimke, G., Buchinger, R.: Vergleichende experimentelle Untersuchungen an Bioglas (L. L. Hench), Al2O3-Keramik und mit mod. Bioglas beschichteter Al2O3 Keramik. 1. Ergebnisse mit unbelasteten Implantaten. Arch. orthop. Unfall-Chir. 90, 15–27 (1977b)
Griss, P., Werner, E., Heimke, G., Buchinger, R.: Vergleichende experimentelle Untersuchungen an Bioglas (L. L. Hench), Al2O3-Keramik und mit mod. Bioglas beschichteter Al2O3 Keramik. 2. Ergebnisse an belasteten Implantaten. Arch. orthop. Unfall-Chir. 91 (im Druck)
Harms, J., Mäusle, E.: Vergleichende makroskopische und mikroskopische Befunde am Kapselgewebe der Hüfte nach Total alloplastik. Orthop. Praxis 13, 33–35 (1977)
Hastings, G. W., Thank Thuy, T.: Biomechanical Compatible Materials: Carbon Fibre Reinforced Plastics. In: Biocompatibility of Implant Materials (Ed. D. Williams), p. 128–133. London: Sector Publishing Ltd. 1976
Heimke, G., Beisler, W., Andrian-Werburg, H. v., Griss, P., Krempien, B.: Untersuchungen an Implantaten aus Al2O3 Keramik. Ber. Dtsch. Keram. Ges. 50, 4–8 (1973)
Heimke, G., Griss, P., Krempien, B.: Eine Hüftgelenk-Total-endoprothese zur teilweise zementfreien Implantation. Acta Medicotechnica 23, 243–247 (1975)
Heimke, G., Griss, P., Jentschura, G.: Verbesserter Gelenkersatz mit Aluminiumoxid-Keramik. Ber. Dtsch. Keram. Ges. 53, 329–332 (1976)
Heimke, G., Griss, P.: Diskussionsbemerkung, Tagung „Ma-terials for Use in Medicine und Biology”, Cambridge, GB, Juli 1974; wiedergegeben in: Biocompatibility of Implant Materials (Ed. D. Williams), p. 68–69. London: Sector Publishing Ltd. 1976
Heimke, G., Griss, P., Jentschura, G.: Möglichkeiten und Grenzen keramischer Endoprothesen. Sci. Ceram. 9, 212–218 (1977)
Hench, L. L., Greenlee, T., Allen, W. C., Piotrowski, G.: An Investigation of Bonding Mechanisms at the Interface of a Prosthetic Material. US Army Med. Res. and Development Command, Contract No DADA 17.70.C.001 Report No. 1 (1970) bis 6 (1975)
Klawitter, J. J., Hulbert, S. F., Talbert, C. D., Fits, C. F., Mathews, R. S., Stelling, F. H.: Materials of Construction for Bone Grap Bridges. Orthopaedic Surgery Papers of the Duke University Medical Center, Jan. 1969
Klawitter, J. J., Hulbert, S. F.: Application of Porous Ceramics for the Attachment of Load Bearing Internal Orthopedic Applications. J. Biomed. Mater. Res. Symposium No. 2 (Part 1), 11–229 (1971)
Köster, K., Heide, H., König, R.: Resorbierbare Calziumphosphatkeramik im Tierexperiment unter Belastung. Langenbecks Arch. klin. Chir. 343, 173–181 (1977)
Rossak, K., Brinkmann, K. E.: Erste Erfahrungen mit einer zementlos zu verankernden Keramikprothese zur Austauschoperation ausgelockerter Total endoprothesen. Z. Orthop. 115, 290–299 (1977)
Schulte, W., Heimke, G.: Das Tübinger Sofort-Implantat. Quintessenz 17–23 (1976)
Strunz, V., Bunte, M., Stellmach, R., Gross, U., Kühl, K., Newessely, H., Brömer, H., Deutscher, K.: Glaskeramik als bioaktives Imp lantationsmaterial. Dtsch. zahndrztl. Z. 31, 69–70 (1976)
Strunz, V., Bunte, M., Stellmach, R., Gross, U. M., Kühl, K., Brömer, H., Deutscher, K.: Bioaktive Glaskeramik als Implantationsmaterial in der Kieferchirurgie. Dtsch. zahnärztl. Z. 32, 287–290 (1977)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Heimke, G., Griss, P., Jentschura, G. et al. Die aussagefähigkeit histologischer befunde zur beurteilung von knochenersatzwerkstoffen. Arch. Orth. Traum. Surg. 91, 267–276 (1978). https://doi.org/10.1007/BF00389609
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00389609