Summary

Different groups have observed and reported deviating tissue reactions for the same material for bone replacement: for the “bioinert” Al2O3-ceramic close bone contact is mentioned, others report about a soft tissue layer adjacent to the implant; for the “bioactive” glass ceramic interfaces capable to transmit considerable shear forces are described, others found no interface bonding.—The analysis of the results of animal experiments and the evaluation of clinical follow-up studies show that these discrepancies had been caused by the differences of the biomechanical situations in the examined interfaces. It is pointed out that the negligence or not mentioning of the load pattern at the site of examination can lead to misinterpretations about the possibilities and limits of applicability of biomaterials.

Zusammenfassung

Am gleichen Knochenersatzmaterial haben verschiedene Arbeitsgruppen unterschiedliche Gewebereaktionen beobachtet und beschrieben: Bei der „bioinerten” Al2O3-Keramik werden einmal enger Knochenkontakt, von anderen die Existenz eines Weichgewebeinterponates erwähnt; für “bioaktive” Glaskeramiken werden einmal Scherkräfte von beträchtlicher Größe übertragende Grenzflächen beschrieben, andere fanden keine Grenzflächenhaftung. — Die Analysen tierexperimenteller Ergebnisse und die Auswertungen klinischer Nachsorgeuntersuchungen zeigen, daß these Diskrepanzen durch die Unterschiede in der biomechanischen Situation der jeweils untersuchten Grenzflächen hervorgerufen worden Bind. Es wird darauf hingewiesen, daß die Nichtbeachtung oder die Nichtnennung des Belastungs zustandes am Ort der Probeentnahme zu Fehlbeurteilungen über die Anwendungsmöglichkeiten und -grenzen von Biomaterialien führt.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Andrian-Werburg, H. v., Griss, P., Krempien, B., Heimke, G.: Klinische Problematik und experimentelle morphologische Befunde bei der Verwendung keramischer Werkstoffe in der Orthopädie und Unfallchirurgie. Z. Orthop. 111, 577–579 (1973)

    PubMed  Google Scholar 

  • Beckham, C. A., Greenlee, T. C., Crebo Jr., A. R.: Bone Formation at a Ceramic Implant Interface. Calc. Tiss. Res. 8, 165–171 (1971)

    Google Scholar 

  • Blencke, B., Brömer, H., Deutscher, K.: Glaskeramik-ein neuer, bioaktiver Implantatwerkstoff. Med. Orthop. Technik 95, 144–148 (1975)

    Google Scholar 

  • Christel, P., Derethe, P., Sedel, L.: A Simulator to Study on Fresh Cadaver the Mechanical Behaviour of the Normal and Prosthetic Hip. First European Conference on Evaluation of Biomaterials, Strassburg, Vortrag I. 3. 2., 25.–28. Sept. 1977

  • Deutscher, K., Brömer, H., Blencke, B., Pfeil, H., Strunz, V.: Properties of a Bio-Active Implant Material. Sci. Ceram. 9, 219–225 (1977)

    Google Scholar 

  • Ducheyne, P., DeMeester, P., Aernoudt, E., Martens, M., Mullier, J. C.: Influence of a Functional Dynamic Loading on Bone Ingrowth into Surface Pores of Orthopedic Implants. J. Biomed. Mater. Res. 11, 811–838 (1977)

    PubMed  Google Scholar 

  • Dunn, E. J., White, E. W.: Bone Ingrowth in Porous Implants. In: Biocompatibility of Implant Materials (Ed. D. Williams), p. 80–84. London: Sector Publishing Ltd. 1976

    Google Scholar 

  • Geduldig, D., Dörre, E., Happel, M., Lade, R., Prüssner, P., Willert, H.-G., Zichner, L.: Welche Aussicht hat die Biokeramik als Implantatmaterial in der Orthopädie? Med. Orthop. Technik 95, 138–143 (1975)

    Google Scholar 

  • Geduldig, D., Lade, R., Prüssner, P., Willert, H.-G., Zichner, L., Dörre, E.: Experimental Investigations of Dense Alumina Ceramic for Hip and Knee Joint Replacements. In: Engineering in Medicine. 2. Artificial Hip and Knee Joint Technology (Ed. M. Schaldach, D. Hohmann), p. 434–445. Berlin-Heidelberg-New York: Springer 1976

    Google Scholar 

  • Griss, P., Krempien, B., Andrian-Werburg, H. v., Heimke, G., Fleiner, R.: Experimentelle Untersuchung zur Gewebsverträglichkeit oxidkeramischer (A1203) Abriebteilchen. Arch. orthop. Unfall-Chir. 76, 270–279 (1973 a)

    Google Scholar 

  • Griss, P., Andrian-Werburg, H. v., Krempien, B., Heimke, G.: Biological Activity and Histocompatibility of Dense Al2O3/MgO Ceramic Implants in Rats. J. Biomed. Mater. Res. Symposium No. 4, 453–462 (1973b)

  • Griss, P., Heimke, G., Krempien, B., Silber, R., Haehner, H., Merkle, B.: Erste Erfahrungen mit der Keramik-Metallverbundprothese. Med. Orthop. Technik 95, 159–162 (1975a)

    Google Scholar 

  • Griss, P., Heimke, G., Andrian-Werburg, H. v., Krempien, B., Reipa, S., Lauterbach, H. J., Hartung, H. J.: Morphological and Biomechanical Aspects of Al2O3 Ceramic Joint Replacement. Experimental Results and Design Considerations for Human Endoprotheses. J. Biomed. Mater. Res. Symposium No. 6, 177–188 (1975b)

  • Griss, P., Heimke, G., Andrian-Werburg, H. v.: Die Aluminiumoxidkeramik-Metall-Verbundprothese. Fine neue Hüftge-lenktotalendoprothese zur teilweise zementfreien Implantation. Arch. orthop. Unfall-Chir. 81, 259–266 (1975c)

    Google Scholar 

  • Griss, P., Heimke, G., Krempien, B., Jentschura, G.: Ceramic Hip Joint Replacement-Experimental Results and Early Clinical Experience. In: Engineering in Medicine, Vol. 2, Advances in Artificial Hip and Knee Joint Technology, p. 446–455 (Ed. M. Schaldach, D. Hohmann). BerlinHeidelberg-New York: Springer 1976a

    Google Scholar 

  • Griss, P., Heimke, G., Krempien, D., Hartung, H. J., Reipa, S., Lauterbach, H. J., Diehm, Th.: Experimental Ceramic Joint Replacement. In: Biocompatibility of Implant Materials (Ed. D. Williams), p. 70–79. London: Sector Publishing Ltd. 1976b

    Google Scholar 

  • Griss, P., Greenspan, D. C., Heimke, G., Krempien, B., Buchinger, R., Hench, L. L., Jentschura, G.: Evaluation of a Bioglas-Coated Al2O3 Total Hip Prosthesis in Sheep. J. Biomed. Mater. Res. Symposium No. 7, 511–518 (1976c)

  • Griss, P., Werner, E., Buchinger, R., Heimke, G.: Die Mannheimer Oxidkeramik-Metall-Verbundendoprothesen. Arch. orthop. Unfall-Chir. 87, 73–84 (1977a)

    Google Scholar 

  • Griss, P., Werner, E., Heimke, G., Buchinger, R.: Vergleichende experimentelle Untersuchungen an Bioglas (L. L. Hench), Al2O3-Keramik und mit mod. Bioglas beschichteter Al2O3 Keramik. 1. Ergebnisse mit unbelasteten Implantaten. Arch. orthop. Unfall-Chir. 90, 15–27 (1977b)

    Google Scholar 

  • Griss, P., Werner, E., Heimke, G., Buchinger, R.: Vergleichende experimentelle Untersuchungen an Bioglas (L. L. Hench), Al2O3-Keramik und mit mod. Bioglas beschichteter Al2O3 Keramik. 2. Ergebnisse an belasteten Implantaten. Arch. orthop. Unfall-Chir. 91 (im Druck)

  • Harms, J., Mäusle, E.: Vergleichende makroskopische und mikroskopische Befunde am Kapselgewebe der Hüfte nach Total alloplastik. Orthop. Praxis 13, 33–35 (1977)

    Google Scholar 

  • Hastings, G. W., Thank Thuy, T.: Biomechanical Compatible Materials: Carbon Fibre Reinforced Plastics. In: Biocompatibility of Implant Materials (Ed. D. Williams), p. 128–133. London: Sector Publishing Ltd. 1976

    Google Scholar 

  • Heimke, G., Beisler, W., Andrian-Werburg, H. v., Griss, P., Krempien, B.: Untersuchungen an Implantaten aus Al2O3 Keramik. Ber. Dtsch. Keram. Ges. 50, 4–8 (1973)

    Google Scholar 

  • Heimke, G., Griss, P., Krempien, B.: Eine Hüftgelenk-Total-endoprothese zur teilweise zementfreien Implantation. Acta Medicotechnica 23, 243–247 (1975)

    Google Scholar 

  • Heimke, G., Griss, P., Jentschura, G.: Verbesserter Gelenkersatz mit Aluminiumoxid-Keramik. Ber. Dtsch. Keram. Ges. 53, 329–332 (1976)

    Google Scholar 

  • Heimke, G., Griss, P.: Diskussionsbemerkung, Tagung „Ma-terials for Use in Medicine und Biology”, Cambridge, GB, Juli 1974; wiedergegeben in: Biocompatibility of Implant Materials (Ed. D. Williams), p. 68–69. London: Sector Publishing Ltd. 1976

    Google Scholar 

  • Heimke, G., Griss, P., Jentschura, G.: Möglichkeiten und Grenzen keramischer Endoprothesen. Sci. Ceram. 9, 212–218 (1977)

    Google Scholar 

  • Hench, L. L., Greenlee, T., Allen, W. C., Piotrowski, G.: An Investigation of Bonding Mechanisms at the Interface of a Prosthetic Material. US Army Med. Res. and Development Command, Contract No DADA 17.70.C.001 Report No. 1 (1970) bis 6 (1975)

  • Klawitter, J. J., Hulbert, S. F., Talbert, C. D., Fits, C. F., Mathews, R. S., Stelling, F. H.: Materials of Construction for Bone Grap Bridges. Orthopaedic Surgery Papers of the Duke University Medical Center, Jan. 1969

  • Klawitter, J. J., Hulbert, S. F.: Application of Porous Ceramics for the Attachment of Load Bearing Internal Orthopedic Applications. J. Biomed. Mater. Res. Symposium No. 2 (Part 1), 11–229 (1971)

  • Köster, K., Heide, H., König, R.: Resorbierbare Calziumphosphatkeramik im Tierexperiment unter Belastung. Langenbecks Arch. klin. Chir. 343, 173–181 (1977)

    Google Scholar 

  • Rossak, K., Brinkmann, K. E.: Erste Erfahrungen mit einer zementlos zu verankernden Keramikprothese zur Austauschoperation ausgelockerter Total endoprothesen. Z. Orthop. 115, 290–299 (1977)

    PubMed  Google Scholar 

  • Schulte, W., Heimke, G.: Das Tübinger Sofort-Implantat. Quintessenz 17–23 (1976)

  • Strunz, V., Bunte, M., Stellmach, R., Gross, U., Kühl, K., Newessely, H., Brömer, H., Deutscher, K.: Glaskeramik als bioaktives Imp lantationsmaterial. Dtsch. zahndrztl. Z. 31, 69–70 (1976)

    Google Scholar 

  • Strunz, V., Bunte, M., Stellmach, R., Gross, U. M., Kühl, K., Brömer, H., Deutscher, K.: Bioaktive Glaskeramik als Implantationsmaterial in der Kieferchirurgie. Dtsch. zahnärztl. Z. 32, 287–290 (1977)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Heimke, G., Griss, P., Jentschura, G. et al. Die aussagefähigkeit histologischer befunde zur beurteilung von knochenersatzwerkstoffen. Arch. Orth. Traum. Surg. 91, 267–276 (1978). https://doi.org/10.1007/BF00389609

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00389609

Navigation