Skip to main content
Log in

Anwendung der blutgasanalyse bei bewertung der dauerleistungsfähigkeit von holzhauern

Use of blood gas analysis for the evaluation of long-term physical efficiency in Lumbermen

  • Original Works
  • Published:
International Archives of Occupational and Environmental Health Aims and scope Submit manuscript

Summary

Performance capacity values were established during bicycle-ergometer exercise with 68 lumbermen. Accordingly the base excess in capillary blood increased by 4.5 and 2.5 mMol/l, against initial anaerobic and aerobic threshold values, respectively. In the 26–35 year age group, the anaerobic threshold was found to have average values of 187 W (ergometric load), related to an oxygen uptake of 36 ml/min per kg weight (81% of the aerobic capacity) and a heart frequency of 161 pulses/min. Corresponding values for the aerobic threshold were 150 W, 30 ml/min, 66% and 142 pulses/min. It is considered that the endurance working capacity of manual labourers can be better judged using the proposed blood-gas analysis, than by determination of the maximum oxygen uptake.

Zusammenfassung

Während fahrradergometrischer Belastung wurden bei 68 Holzhauern leistungsphysiologische Größen entsprechend der Veränderung des Basenüberschusses im Kapillarblut um 4,5 bzw. 2,5 mMol/l gegenüber dem Ausgangswert (anaerobe bzw. aerobe Schwelle) ermittelt. Bei den 26–35-jährigen lag die anaerobe Schwelle, bezogen auf ergometrische Leistung, im Durchschnitt bei 187 W, bezogen auf die Sauerstoffaufnahme bei 36 ml/min pro kg Gewicht, resp. bei 81% der aeroben Kapazität und bezogen auf Herzfrequenz bei 161 Puls/min. Für die aerobe Schwelle betragen die Werte 150 W, 30 ml/min, 66% und 142 Puls/min. Es wird die Ansicht vertreten, daß sich die Dauerleistungsfähigkeit des Schwerarbeiters mit Hilfe der vorgeschlagenen Anwendung der Blutgasanalyse besser beurteilen läßt als durch die Bestimmung der maximalen Sauerstoffaufnahme.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Åstrand, P. O., Rhyming, I: A nomogram for calculation of aerobic capacity from pulse rate during submaximal work. J. Appl. Physiol. 10, 218–221 (1954)

    Google Scholar 

  • Bouhuys, A., Pool, J., Binkhorst, R. A., Van Leeuwen, P.: Metabolic acidosis of exercise in healthy males. J. Appl. Physiol. 21, 1040–1046 (1966)

    PubMed  Google Scholar 

  • Croonen, F., Binkhorst, R. A.: Oxygen uptake calculated from expiratory volume and oxygen analysis only. Ergonomics 17, 113–117 (1974)

    PubMed  Google Scholar 

  • Davis, J. A., Vodak, P., Wilmore, J. H.: Anaerobic threshold and maximal aerobic power for 3 modes of exercise. J. Appl. Physiol. 41, 544–550 (1976)

    PubMed  Google Scholar 

  • Durnin, J. V. G. A., Womersley, J.: Body fat assesed from total body density and its estimation from skinfold thickness. Br. J. Nutr. 32, 77–96 (1974)

    PubMed  Google Scholar 

  • Hollmann, W., Hettinger, T.: Sportmedizin, Arbeits- und Trainingsgrundlagen. Stuttgart, New York: Schattauer 1976

    Google Scholar 

  • Hollmann, W., Liesen, H.: Über die Bewertbarkeit des Lactats in der Leistungsdiagnostik. Sportarzt + Sportmed. 8, 175–182 (1973)

    Google Scholar 

  • Holloszy, J. O., Oscay, L. B., Mole, P. A., Don, I. J.: Biochemical adaptations to endurance exercise in skeletal muscle. In: Muscle metabolism during exercise. New York: Plenum Press 1971

    Google Scholar 

  • Keul, J., Kindermann, W., Simon, G.: Die aerobe und anaerobe Kapazität als Grundlage für die Leistungsdiagnostik. Leistungssport 8, 22–32 (1978)

    Google Scholar 

  • Liesen, H., Mader, A., Heck, H., Hollmann, W.: Die Ausdauerleistungsfähigkeit bei verschiedenen Sportarten unter besonderer Berücksichtigung des Metabolismus: Zur Ermittlung der optimalen Belastungsintensität im Training. Beiheft zu: Leistungssport 9, 63–79 (1977)

    Google Scholar 

  • Mader, A., Liesen, H., Heck, H., Philippi, H., Rost, R., Schuerch, P., Hollmann, W.: Zur Beurteilung der sportart-spezifischen Ausdauerleistungsfähigkeit im Labor. Sportarzt + Sportmed. 27, 80–88, 109–112 (1976)

    Google Scholar 

  • Shephard, R. J.: World standards of cardiorespiratory performance. Arch. Environ. Health 13, 664–672 (1966)

    PubMed  Google Scholar 

  • Thews, G., Harnoncourt, K.: Ein Säure-Basen-Nomogramm für die klinische Routinediagnostik. Wien. Med. Wochenschr. 122, 663–665 (1972)

    PubMed  Google Scholar 

  • Valentin, H., Holzhauser, K. P.: Funktionsprüfung von Herz und Kreislauf. Köln: Deutscher Ärzteverlag 1976

    Google Scholar 

  • Wahlund, H.: Determination of physical working capacity. Acta Med. Scand. [Suppl.] 215, 1–78 (1948)

    Google Scholar 

  • Wassermann, K., Whipp, B. J., Koyal, S. N, Beaver, W. L.: Anaerobic threshold and respiratory gas exchange during exercise. J. Appl. Physiol. 35, 236–243 (1973)

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Buchberger, J. Anwendung der blutgasanalyse bei bewertung der dauerleistungsfähigkeit von holzhauern. Int. Arch Occup Environ Heath 44, 45–53 (1979). https://doi.org/10.1007/BF00381207

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00381207

Key words

Schlüsselwörter

Navigation