Finger systolic pressure during local cooling in normal subjects aged 20 to 60 years: reference values for the assessment of digital vasospasm in Raynaud's phenomenon of occupational origin

  • Published:
International Archives of Occupational and Environmental Health Aims and scope Submit manuscript

Summary

Measurements of finger systolic pressure (FSP) during a standardized cold test (finger cooling to 30, 15 and 10°C during 5 min ischemia) were performed on 103 healthy subjects divided into four subgroups according to age: 20–29 years (n = 22), 30–39 years (n = 32), 40–49 yr (n = 27), 50–60 years (n = 22). Among the age groups there was no difference in the reduction of FSP (FSP%) and in the digit-to-brachial systolic pressure index (DBI%) after cold provocation at 15 and 10°C. Cold-induced digital vasoconstriction was more intense in smokers than in non smokers (P = 0.025). In the entire study population the lower normal limits of FSP% were 74% at 15°C and 63% at 10°C. Using an FSP%10 of <60% as a discriminating threshold between normals and patients with vibration white finger, the sensitivity of the cold test was 87% and the specificity was 100%. The findings of this study suggest the following considerations: (a) age does not seem to influence the digital arterial response to cold in healthy subjects; (b) smoking has a harmful effect on finger cold reaction in normal individuals; (c) the measurement of FSP during cooling is an accurate method of objectively diagnosing Raynaud's phenomenon of occupational origin.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ekenvall L, Lindblad LE (1986) Vibration white finger and digital systolic pressure during cooling. Br J Ind Med 43:280–283

    Google Scholar 

  2. Nielsen SL, Lassen NA (1977) Measurement of digital blood pressure after local cooling. J Appl Physiol 43:907–910

    Google Scholar 

  3. Nielsen SL, Sørensen CJ, Olsen N (1980) Thermostatted measurement of systolic blood pressure on cooled fingers. Scand J Clin Lab Invest 40:683–687

    Google Scholar 

  4. Nielsen SL, Lassen NA (1982) Finger systolic pressure in upper extremities testing for cold sensitivity (Raynaud's phenomenon). In: Bernstein EF (ed) Noninvasive diagnostic techniques in vascular disease. The CV Mosby Company, London, pp 410–416

    Google Scholar 

  5. Olsen N, Nielsen SL, Voss P (1982) Cold response of digital arteries in chain saw operators. Br J Ind Med 39:82–88

    Google Scholar 

  6. Olsen N, Fjeldborg P, Brøchner-Mortensen J (1985) Sympathetic and local vasoconstrictor response to cold in vibration induced white finger. Br J Ind Med 42:272–275

    Google Scholar 

  7. Thulesius O, Brubakk A, Berlin E (1981) Response of digital blood pressure to cold provocation in cases with Raynaud's phenomenon. Angiology 32:113–118

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bovenzi, M. Finger systolic pressure during local cooling in normal subjects aged 20 to 60 years: reference values for the assessment of digital vasospasm in Raynaud's phenomenon of occupational origin. Int. Arch Occup Environ Heath 61, 179–181 (1988). https://doi.org/10.1007/BF00381016

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00381016

Key words

Navigation