Summary

In addition to the improved, universal usable, electronic-hydraulic directed hip-joint-simulator type “MÜNCHEN I”, a new simulator with simplified construction has been developed. This mechanical hip-joint-simulator is marked by a dual drive of movement and strain mechanism, that has been realized by a toothed belt drive. The adjustable, three-axial movement simulates level walking. According to its special, easier design the new simulator is highly adapted for comparative testing of total hip endoprostheses regarding the fields of quality improvement or standardization testing.

Zusammenfassung

In Ergänzung zu dem bewährten, universell einsetzbaren, elektronisch-hydraulisch gesteuerten Hüftgelenksimulator Typ „MÜNCHEN I” wurde ein neuer Simulator mit vereinfachtem Aufbau entwickelt. Dieser mechanische Hüftsimulator ist gekennzeichnet durch einen gemeinsamen Antrieb von Bewegungs- und Belastungsmechanismus, der mittels Zahnriementrieb realisiert wurde. Die einstellbare, dreiaxiale Bewegung entspricht dem Gehen auf ebener Fläche. Durch den speziellen, einfacheren Aufbau ist der neue Simulator zur vergleichenden Prüfung von totalen Hüftendoprothesen im Bereich der Qualitäts-sicherung oder Normprüfung besonders geeignet.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Ungethum M., Hildebrandt, J., Jäger, M., Moslé, H. G.: Ein neuer Simulator zur Testung von Totalendoprothesen für das Hüftgelenk. Arch. orthop. Unfall-Chir. 77, 304 (1973)

    Google Scholar 

  • Hinterberger, J., Ungethüm, M.: Untersuchungen zur Tribologie und Festigkeit von Aluminiumoxidkeramik-Hüftendoprothesen. Z. Orthop. (im Druck)

Download references

Author information

Authors and Affiliations

Authors

Additional information

Die in diesem Bericht zugrundeliegenden Arbeiten wurden mit Mitteln des Bundesministers für Forschung und Technologie (Kennzeichen MT 267) gefördert. Der Bundesminister für Forschung und Technologie übernimmt keine Gewähr für die Richtigkeit, die Genauigkeit und Vollstandigkeit der Angaben sowie für die Beachtung privater Rechte Dritter

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ungethüm, M., Hinterberger, J. Münchener hüftgelenksimulator der 2. Generation. Arch. Orth. Traum. Surg. 91, 233–237 (1978). https://doi.org/10.1007/BF00379757