Die anwendbarkeit von butylcyanoacrylat in der biomechanik zur applikation von dehnungsmeßstreifen auf nativem gewebe

Butylcyanoacrylate-an adhesive for bonding strain gages to non-fixed biological materials

  • Originalarbeiten
  • Published:
Archives of orthopaedic and traumatic surgery Aims and scope Submit manuscript

Summary

Creep, hysteresis, stability, elongation capability and repeatability of butylcyanoacrylate as a proper adhesive for bonding strain gages to non-fixed tissues have been tested with good results. Due to its excellent bonding performance butylcyanoacrylate provides the only means for bonding electrical resistance foil strain gages to biological materials for the time being. This opens new aspects for strain measurements with strain gages in the biomechanical field.

Zusammenfassung

Das Kriech-und Hysteresis-Verhalten, die Nullpunktstabilität, Dehnfähigkeit und Reproduzierbarkeit des Klebstoffes Butylcyanoacrylat wurde im Hinblick auf seine Verwendbarkeit zur Applikation von Dehnungsmeßstreifen auf nativem Gewebe einer eingehenden Materialprüfung unterzogen. Die Ergebnisse weisen Butylcyanoacrylat als einen für die DMS-Applikation auf nativem Gewebe geeigneten Klebstoff aus. Wegen der hohen Anforderungen an die Applikationsbedingungen sind zur Prüfung von Werkstoffen die bereits erprobten DMS-Kleber vorteilhafter. Aufgrund seiner hervorragenden Klebeeigenschaften an biologischem Material stellt Butylcyanoacrylat jedoch derzeit die einzige Möglichkeit dar, Dehnungs meßstreifen unmittelbar auf nativem Gewebe zu applizieren. Dadurch werden in der Biomechanik neue Meßmöglichkeiten eröffnet.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Bass, P., Callantine, M. R.: Simultaneous recording of electrical and mechanical activity of the uterus in the unanaesthetized animal. Nature (Lond.) 209, 1367 (1964)

    Google Scholar 

  • Brennwald, J., Perren, S. M.: In vivo Messung der belastungsabhängigen Knochendehnung. Helv. Chir. Acta 41, 455 (1974)

    Google Scholar 

  • Carlson, G. M., Ruddon, R. W., Bass, P.: Inhibitory effect of nicotine upon gastrointestinal contractile activity in the dog. Fed. Proc. 27, 449 (1968)

    Google Scholar 

  • Cochran, G. V. B.: Implantation of strain gages on bone in vivo. J. Biomech. 5, 119 (1972)

    Google Scholar 

  • Diehl, K., Hanser, U., Hort, W.: Erfassung mechanischer Beanspruchung von Skelett-Teilen bei der Osteosynthese mittels Dehnungsmeßstreifen. MOT 95, 72 (1975)

    Google Scholar 

  • Dominic, J. A., Reincke, D. A.: Extraluminal force Transducer for in vivo measurement of rabbit uterine contractile activity. Fertil. and Steril. 19, 945 (1968)

    Google Scholar 

  • Edwards, R. G., Lafferty, J. F., Lange, K. O.: Ligament strain in the human knee joint. J. Basic. Engineer. 3, 131 (1970)

    Google Scholar 

  • Egry, G., Somogyvari, K.: Die Anwendung von Gewebsklebemitteln bei Magen-Darmoperationen. Chirurg 42, 1 (1971)

    Google Scholar 

  • Eichelter, P., Meissner, K., Schürer-Waldheim, H.: Bronchusstumpfverschluß durch eine neue Klebetechnik. Kunststoffe in der Medizin, Symposium, Innsbruck, S. 135, 1969

  • Elzinga, W. E.: Myocardial contractile force as monitored by strain gage transducers of intact dog heart. Diss. Michigan State University 1967

  • Evans, F. G.: Stress and strain in bones. Springfield: C. Thomas 1967

    Google Scholar 

  • Feit, A., Freund, M.: The mobility of the uterus in the intact, unaesthetized and unrestrained guinea-pig. Fed. Proc. 25, 251 (1966)

    Article  Google Scholar 

  • Gerlach, H.: Die Verwendung von lyophilisierter Dura und Histoacrylgewebekleber bei der Rekonstruktion der hinteren Gehörgangwand. HNO 19, 202 (1971)

    Google Scholar 

  • Häring, R.: Klebstoff als Nahtersatz in der Chirurgie. Fortschr. Med. 86, 169 (1968)

    Google Scholar 

  • Healey, J. E., Gallager, H. S., Moore, E. B., Clark, R. L., Sheena, K. S., McBride, C. M.: Experiences with plastic adhesive in nonsuture repair of body tissues. Amer. J. Surg. 109, 416 (1965)

    Google Scholar 

  • Heiss, W. H., Guthy, E., Becker, H. M.: Experimentelle Untersuchungen zum Ersatz der chirurgischen Naht durch Klebstoff. Langenbecks Arch. klin. Chir. 308, 793 (1964)

    Google Scholar 

  • Jacoby, H. J., Bass, P., Bennett, D. R.: In vivo extraluminal contractile force transducer for gastrointestinal muscle. J. Appl. Physiol. 18, 658 (1963)

    Google Scholar 

  • Jacoby, H. J., Marshal, C. H.: Gastric motor-stimulating activity of gastrin tetrapeptide in dog. Gastroent. 56, 80 (1969)

    Google Scholar 

  • Kozak, J. A., Flanagan, M. J., McDonald, J. H.: Combined suture with a methyl-2-cyanoacrylate monomer for reanastomosis of the ureter. Trans. Amer. Ass. gen.-urin. Surg. 59, 149 (1967)

    Google Scholar 

  • Lanyon, L. E., Smith, R. N.: Measurements of bone strain in the walking animal. Res. Vet. Sci. 10, 93 (1969)

    Google Scholar 

  • Lissner, H. L., Roberts, V. R.: The response of the human body to impact. In: Biomechanics and related bioengeneering topics, R. M. Kennedy (Hrsg.). New York: Pergamon Press 1964

    Google Scholar 

  • Ludwick, J. R., Bass, P.: Antral and duodenal contractile activity following pyloroplasty and vagotomy. Proc. Canad. Fed. Biol. Soc. 10, 71 (1967)

    Google Scholar 

  • Nachemson, A., Elfstrom, G.: Intravital wireless telemetry of axial forces in Harrington distraction rods in patients with idiopathic scoliosis. J. Bone Jt. Surg. 53-A, 445 (1971)

    Google Scholar 

  • Nelson, T. S., Eigenbrod, E. H., Keoshian, L. A., Bunker, C., Johnson, L.: Alternations in muscular and electrical activity of the stomach following vagotomy. Arch. Surg. 94, 821 (1967)

    Google Scholar 

  • Nicolai, R. J., Schweiker, J. W.: Investigation of root-periodontium interface stresses and displacements of orthodontic application. Exp. Mech. 12, 406 (1972)

    Google Scholar 

  • Pecherstorfer, M., Wiltschke, H., Zinnbauer, B.: Klebeverfahren zum Blasenverschluß bei der suprapubischen Prostatektomie. Wien. klin. Wschr. 82, 357–358 (1970)

    Google Scholar 

  • Perren, S. M., Russenberger, M., Steinmann, S., Müller, M. E., Allgöwer, M.: A dynamic compression plate in cortical bone healing. Acta orthop. scand. Suppl. 125, 31 (1969)

    Google Scholar 

  • Rinecker, H., Brendel, W.: Kontraktionskraft und -frequenz verschiedener Darmabschnitte des Hundes in vivo. Pflügers Arch. 290, 144 (1966)

    Google Scholar 

  • Rowland, C. R., Dominic, J. A., Reinke, D. A.: Rabbit uterine longitudinal and circular muscle in vitro contractile activity. Pharmacologist 9, 217 (1967)

    Google Scholar 

  • Sawyers, J. L., Vasco, J.: Sealing cut lung surfaces with plastic adhesive. J. thorac. cardiovasc. Surg. 46, 526–530 (1963)

    Google Scholar 

  • Sutfin, D. C., Lefer, A. M.: A modified strain gage arch for measurement of heart contractile force. Med. Elektron. Biol. Eng. 1, 371 (1963)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Die Untersuchungen wurden mit Unterstützung der Deutschen Forschungsgemeinschaft durchgeführt

Rights and permissions

Reprints and permissions

About this article

Cite this article

Küsswetter, W., Permooser, F. & Ungethüm, M. Die anwendbarkeit von butylcyanoacrylat in der biomechanik zur applikation von dehnungsmeßstreifen auf nativem gewebe. Arch. Orth. Traum. Surg. 91, 217–221 (1978). https://doi.org/10.1007/BF00379754

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00379754

Navigation