Skip to main content
Log in

The relationship between indoor nitrogen dioxide concentration levels and personal exposure: a pilot study

  • Original Papers
  • Published:
International Archives of Occupational and Environmental Health Aims and scope Submit manuscript

Summary

A small, personal monitoring study was performed in a subpopulation (14 families) of a case-control study on the relationship between indoor nitrogen-dioxide exposure and respiratory diseases of schoolchildren. Mothers, schoolchildren and pre-schoolchildren were asked to carry duplicate Palmes diffusion tubes during one week. Simultaneously nitrogen-dioxide concentrations were measured in the kitchen, living room, bedroom, outdoors and—for a few participants—at school and at work. Information on time activity patterns was gathered by means of a self administered diary. Several models for estimating exposure were constructed and tested against measured exposure. The personal exposure of the participants could well be explained by models containing indoor concentrations. Models with time-weighted average concentrations did not explain personal exposure better than models containing indoor concentrations. A calculated time-weighted average exposure was found to underestimate measured personal exposure by an average 20%, probably because the average concentration in a location does not necessarily reflect the actual exposure in that location. Personal exposure of mothers and children was very similar and highly correlated, indicating that the personal exposure of the mother might be a reasonable estimate for the exposure of the child.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Dockery DW, Spengler JD, Reed MP, Ware J (1980) Relationship among personal indoor and outdoor NO2 measurements. 72nd Annual Meeting Air Pollution Control Association, Montreal

  • Goldstein BD, Melia RJW, Chin S, duV Florey C, Clark D, John HH (1979) The relation between respiratory illness in primary schoolchildren and the use of gas for cooking. II. Factors affecting nitrogen dioxide in the home. Int J Epidemiol 8:339–346

    Google Scholar 

  • Hoek G, Brunekreef B, Meijer R, Scholten A, Boleij J (1984) Indoor nitrogen dioxide pollution and respiratory symptoms of schoolchildren. Int Arch Occup Environ Health 55:79–86

    Google Scholar 

  • Lebret E, van de Wiel HJ, Boleij JSM, Brunekreef B, Noij D, Oranje EJ, Biersteker K (1983) Indoor air pollution in the Netherlands. VIth World Congress on Air Quality, Paris, May 1983, vol 2, pp 271–278

  • Melia RWJ, duV Florey C, Darby S, Palmer E, Goldstein B (1978) Differences in NO2 levels in kitchens with gas or electric cookers. Atmos Environ 12:1379–1381

    Google Scholar 

  • Nitta H, Maeda K (1982) Personal exposure monitoring to nitrogen dioxide. Environ Int 8:243–248

    Google Scholar 

  • Ott WR (1980) Models of human exposure to air pollution. Tech Rep 32: Stanford University

  • Quackenboss JJ, Kanarek MS (1982) Personal monitoring for nitrogen dioxide exposure, methodological considerations for a community study. Environ Int 8:249–258

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hoek, G., Meijer, R., Scholten, A. et al. The relationship between indoor nitrogen dioxide concentration levels and personal exposure: a pilot study. Int. Arch Occup Environ Heath 55, 73–78 (1984). https://doi.org/10.1007/BF00378069

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00378069

Key words

Navigation