Abstract
Following the hot-dip process for zinc coating on weathering steel, the galvanizing bath was found to have picked up copper. The galvanizing bath was observed to pick up Cu from the weathering steel at an average rate of 1.83×10−3% s−1m−2 at 452±2‡C. EDAX/SEM studies exhibited a concentration gradient of copper to exist across the thickness of the galvanized coating on weathering steel. XRD studies revealed the formation of a protective copper complex, {Cu[(OH)2Cu]3}SO4, on galvanized coating containing 0.739% Cu, when exposed in marine and industrial atmospheres. The adherence characteristic of the copper complex to the galvanized coating was found to be very satisfactory.
Similar content being viewed by others
References
J. C. Hudson, J. Iron & Steel Inst., 196 (1960) 333.
D. M. Buck, J. Ind. Engg. Chem., 5 (1913) 447.
D. M. Buck, Proc. ASTM 19 (1919) 224.
H. R. Copson, Proc. ASTM 45 (1945) 554.
W. H. J. Vernon, J. Iron & Steel Inst., 196 (1960) 335.
W. H. J. Vernon, J. Iron & Steel Inst., 196 (1960) 335.
JCPDS, Pennsylvania, Powder Diffraction File No. 13-398 (1972) 523.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Bhattacharjee, A.K., Singh, I. Studies on the presence of copper in the galvanized coating on weathering steel and the adherence characteristic of the protective copper complex formed on galvanized weathering steel. Journal of Materials Science 30, 1617–1620 (1995). https://doi.org/10.1007/BF00375274
Received:
Accepted:
Published:
Issue Date: