Zweidimensionale Ultraschall-Diagnostik von Hirntumoren und Subduralhämatomen mit dem elektronischen Sektor-Scan

Two-dimensional ultrasonic diagnosis of brain tumors and subdural hematomas by electronic sector scanning

  • Published:
Archiv für Psychiatrie und Nervenkrankheiten Aims and scope Submit manuscript

Summary

  1. 1.

    Electronic sector scanning (ESS) is a new two-dimensional ultrasonic technique which provides continuous and instantaneous cross-sections of intracranial structures through the intact skull, including the ventricles and large cerebral arteries, by means of a stationary probe.

  2. 2.

    The efficiency of the ESS in the diagnosis of brain tumors and extracerebral hematomas in 295 neuroradiologically controlled cases out of an unselected number of patients during 1972–1974 is described.

  3. 3.

    Supratentorial brain tumors can be detected directly with the ESS by abnormal reflections of the tumors as well as indirectly by displacement of intracranial reference structures, mainly the ventricular borders. In 239 cases of suspected brain tumor, 126 were neuroradiologically confirmed as supratentorial brain tumors. Among these 126 brain tumors the correct localization was determined by the ESS in 86.5%.

  4. 4.

    The highest reliability of the ESS proved to be the direct demonstration of frontal tumors (93%), whereas space-occupying lesions near the midline could be shown only in 79%. Up to now there have been difficulties in the diagnosis of tumors situated near bony structures, e.g., calvarian meningiomas.

  5. 5.

    Subdural hematomas (56 patients) could be lateralized correctly in 93%. However, direct demonstration of the border of the hematomas could be achieved only in 48,2%. Chronic subdural hematomas in children are easier to recognize and the border could be demonstrated in 18 out of 19 cases.

  6. 6.

    The clinical applicability and diagnostic values of the ESS as a nontraumatic investigation procedure are discussed in comparison to cerebral angiography, pneumoencephalography, brain scintigraphy, and CAT scan.

Zusammenfassung

  1. 1.

    Der elektronische Sektor-Scan (ESS), ein neues zweidimensionales Ultraschall-Untersuchungsverfahren des Gehirns, liefert bei unbewegtem Schallkopf durch den intakten Schädel fortlaufende, momentane Querschnittsbilder intrakranieller Strukturen einschließlich der Ventrikel und Pulsationen der großen cerebralen Gefäße. Diese Echotomogramme sind nach Richtung und Anzahl in beliebig variablen Schnittebenen durch Schädel und Gehirn zu legen.

  2. 2.

    Die Leistungen des ESS bei Hirntumoren und extracerebralen Hämatomen in der klinischneurologischen Diagnostik eines unselektionierten Krankengutes der Jahre 1972 bis 1974 werden anhand von 295 neuroradiologisch kontrollierten Fällen beschrieben.

  3. 3.

    Supratentorielle Hirntumoren können mit dem ESS sowohl direkt durch abnorme Tumorreflexionen als auch indirekt durch Verlagerung intrakranieller Referenzstrukturen, meistens der Ventrikelgrenzen, nachgewiesen werden. Bei 126 neuroradiologisch kontrollierten Großhirntumoren lag die Treffsicherheit des BSS bezüglich der richtigen Lokalisation bei 86,5%.

  4. 4.

    Am zuverlässigsten ist der ESS für den direkten Nachweis von Frontaltumoren (93%), während mittelliniennahe Tumoren nur bei 79% erkennbar waren. Infratentoriell, basal und knochennah gelegene Tumoren sind nicht darstellbar.

  5. 5.

    Beim Nachweis von Subduralhämatomen (56 Patienten) fanden sich in 93% richtige Seitenhinweise, aber nur in 48,2% eine Direktreflektion der Hämatomgrenze. Chronische Subduralhämatome bei Kindern sind besser erkennbar und wurden in 18 von 19 Fällen nachgewiesen.

  6. 6.

    Klinische Anwendbarkeit und diagnostischer Wert des ESS als atraumatische Untersuchungsmethode werden gegenüber Angiographie, Pneumencephalographie, Hirnszintigraphie und CAT-Scan diskutiert.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Ambrose, J.: Computerized x-ray scanning of the brain. J. Neurosurg. 40, 679–695 (1974)

    Article  CAS  Google Scholar 

  2. Aubaniac, R., Porot, I.: Radio-anatomic générale de la tête. Paris: Masson et Cie 1955

    Google Scholar 

  3. Dreese, M. J., McGee, F. E., Harrelson, A. B.: Correlative aids in B-scan echoencephalo graphy. Neurology (Minneap.) 16, 766–770 (1966)

    Article  Google Scholar 

  4. Freund, H. J., Somer, J. C., Kendel, K. H., Voigt, K.: Electronic sector scanning in the diagnosis of cerebrovascular disease and space-occupying processes. Neurology (Minneap.) 23, 1147–1159 (1973)

    Article  CAS  Google Scholar 

  5. Gordon, D.: Zwei- und dreidimensionale Ultra-Schalltechniken in der medizinischen Diagnostik. Schweiz. med. Wschr. 99, 976–984 (1969)

    CAS  PubMed  Google Scholar 

  6. Hofmann, D., Holländer, H. J., Wieser, P.: Neue Möglichkeiten der Ultraschalldiagnostik in der Gynäkologie und Geburtshilfe, Fortschr. Med. 84, 689–693 (1966)

    Google Scholar 

  7. Howry, D. H., Bliss, R. W.: Ultrasonic visualization of soft tissue structures of the body. J. Lab. clin. Med. 40, 579–592 (1952)

    CAS  PubMed  Google Scholar 

  8. Kendel, K., Freund, H. J., Kapp, H., Voigt, K.: Die Darstellung von Hirnarterien mit dem elektronischen Ultraschall-Sector-Scan und ihre diagnostischen Möglichkeiten. Folia angiol. (Pisa) 21, 201–202 (1973)

    Google Scholar 

  9. Kistler, J. P., Hochberg, F. H., Brooks, B. R., Richardson, E. P., New, P. F. J., Schnur, J.: Computerized axial tomography: clinicopathologic correlation. Neurology (Minneap.) 25, 201–209 (1975)

    Article  CAS  Google Scholar 

  10. Krayenbühl, H., Yasargil, M. G.: Die zerebrale Angiographie. Stuttgart: Thieme 1965

    Google Scholar 

  11. Leksell, L.: Kirurgisk behandling av skall skador. Vortrag: Meeting of Svenska Läkarsällskapet, Stockholm, 7. 12. 1954

  12. Leksell, L.: Echo-encephalography. I. Detection of intracranial complications following head injury, Acta chir. scand. 110, 301–315 (1955/56)

    Google Scholar 

  13. Leksell, L.: Echo-encephalography. II. Midline echo from the pineal body as an index of pineal displacement. Acta chir. scand. 115, 255–259 (1958)

    CAS  PubMed  Google Scholar 

  14. McAffee, J. D., Taxdal, D. R.: Comparison of radio-isotope scanning with cerebral angiography and air studies in brain tumor localization. Radiology 77, 207–222 (1961)

    Article  Google Scholar 

  15. Mishkin, F. S., Mealey, J.: Use and interpretation of the brain scan. Springfield, Ill: Chic. C. Thomas 1969

    Google Scholar 

  16. Moore, G. E.: Diagnosis and localization of brain tumors. Springfield, Ill.: Ch. C. Thomas 1953

    Google Scholar 

  17. Müller, H. R., Levy, A., Klingler, M.: Zur Technik der transduralen Echoenzephalographie. Schweiz. Arch. Neurol. Psychiat. 102, 313–315 (1968)

    PubMed  Google Scholar 

  18. Müller, H. R.: Transdurale Echolotung von Hirntumoren mittels einer zweidimensionalen A-Scan-Technik. Schweiz. med. Wschr. 99, 1017–1019 (1969)

    PubMed  Google Scholar 

  19. Mundinger, F., Ostertag, C.: Radio-Isotope in der neurologisch-neurochirurgischen Diagnostik. Hippokrates 42, 135–156 (1971)

    CAS  PubMed  Google Scholar 

  20. New, P. F. J., Scott, W. R., Schnur, J. A., Davis, K. R., Taveras, J. M., Hochberg, F. H.: Computed tomography with the EMI Scanner in the diagnosis of primary and metastatic intracranial neoplasms. Radiology 114, 75–87 (1975)

    Article  CAS  Google Scholar 

  21. Rott, H. D., Huber, H. J., Soldner, R., Schwanitz, G.: Chromosomenuntersuchungen nach Einwirkung von Ultraschall auf menschliche Lymphozyten in vitro. Electromedica 1, 14–16 (1972)

    Google Scholar 

  22. Schiefer, W., Kazrier, E.: Klinische Echo-Encephalographie. Berlin-Heidelberg-New York: Springer 1967

    Book  Google Scholar 

  23. Somer, J. C.: Electronic sector scanning for ultrasonic diagnosis. Ultrasonics 6, 153–159 (1968)

    Article  CAS  Google Scholar 

  24. Somer, J. C.: Electronic sector scanning for ultrasonic beams. In: J. Böck, K. Ossoinig, Ultrasonographia Medica. Wien: Verlag der Wien. Med. Akad. 1971

    Google Scholar 

  25. Tanaka, K., Ito, K., Ohara, Y.: Ultrasonotomography of the brain. In: E. Kazner, W. Schiefer, K. J. Zülch, Proc. in Echo-Encephalography. Berlin-Heidelberg-New York: Springer 1968

    Chapter  Google Scholar 

  26. Voigt, K.: Der elektronische Sektor-Scan in der neurologischen Diagnostik. Habil.-Schrift, Freiburg 1973

  27. Wang, Y., Paoletti, P.: Radionuclide applications in neurology and neurosurgery. Spring-field, Ill.: Ch. C. Thomas 1970

    Google Scholar 

  28. Wild, J. J., Reid, J. M.: Applications of echo-ranging techniques to determination of structures of biological tissues. Science 115, 226–230 (1952)

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Die Untersuchungen wurden unterstützt durch die Deutsche Forschungsgemeinschaft über den Sonderforschungsbereich „Hirnforschung und Sinnesphysiologie“ (SFB 70).

Rights and permissions

Reprints and permissions

About this article

Cite this article

Voigt, K., Kendel, K., Büdingen, H.J. et al. Zweidimensionale Ultraschall-Diagnostik von Hirntumoren und Subduralhämatomen mit dem elektronischen Sektor-Scan. Arch. Psychiat. Nervenkr. 220, 307–323 (1975). https://doi.org/10.1007/BF00342061

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00342061

Key words

Schlüsselwörter

Navigation