Summary
The sciatic nerve fibres of 6 mice, 5 rats, 3 guinea pigs, 1 cat, and 1 dog were analysed after fixation with Glutaraldehyde+Flemming's fluid and staining with Sudan Black B. For comparison, the phrenic nerve of the dog was fixed and stained in the same way.
-
1.
Using this technique, the nerve fibres shrank 6–8%.
-
2.
Depending on the species, the sciatic nerve contained many or few fibre bundles.
-
3.
On a double logarithmic scale the relationship between the mean number of fibres in the sciatic nerve and the mean body weight of animals of a group (species) was linear.
-
4.
Measurements of fibre size confirmed the results of Häggqvist (1948), taking into account a greater shrinkage of fibres in his preparations. In our preparations, the fibres in the mouse were the smallest, and those in the dog were the thickest.
-
5.
The small and medium-sized fibres with diameters up to 6 μ comprised the greatest part of the fibre population of the sciatic nerve.
-
6.
In smaller animals (mouse, rat, guinea pig), the ratio between nerve conduction velocity and fibre diameter (large-sized fibres) was 6.1:1, as was also shown for cats by Hursh (1939) and Boyd (1965).
Zusammenfassung
Nn. ischiadici von 6 Mäusen, 5 Ratten, 3 Meerschweinchen, 1 Hund und 1 Katze wurden nach Glutaraldehyd-Flemming-Fixierung und Sudanschwarz B-Färbung faseranalytisch untersucht:
-
1.
Die Schrumpfung der Nervenfaserquerschnitte beträgt bei dieser Technik 6–8%.
-
2.
Es gibt kein konstantes morphologisches Bild des N. ischiadicus; bündelreiche Nerventypen kommen neben bündelarmen vor.
-
3.
Zwischen der Körpergröße eines Tieres und der Faserzahl des N. ischiadicus besteht eine direkte Proportionalität.
-
4.
Faserkaliber-Messungen bestätigen im Prinzip die von Häggqvist (1948) ermittelten Zahlen, wenn man die starke Schrumpfung in den Präparaten dieses Autors entsprechend berücksichtigt. Die Fasern der Maus erweisen sich im eigenen Material als die feinsten, die des Hundes als die gröbsten.
-
5.
Die Gruppe der feinen und mittleren Faserkaliber mit einem Durchmesser bis zu einschließlich 6 μ macht den jeweils größten Prozentsatz der Gesamtfaserzahl des N. ischiadicus aus.
-
6.
Bei den kleineren Tierarten (Maus, Ratte, Meerschweinchen) ergibt sich eine Relation der Leitungsgeschwindigkeit der α-Fasern zu ihrem Gesamtdurchmesser von 6,1∶:1, wie schon Hursh (1939) und Boyd (1965) für die Nervenfasern der Katze angegeben haben.
Similar content being viewed by others
Literatur
Björkmann, A., Wohlfart, G.: Faseranalyse des N. oculomotorius, trochlearis und abducens des Menschen und des N. abducens verschiedener Tiere. Z. mikr.-anat. Forsch. 39, 631–647 (1936).
Boyd, J. A.: In: Curtis, D. R. and A. K. Mc Intyre (eds.), Studies in physiology. Berlin-Heidelberg-New York: Springer 1965.
Brownlee, K. A.: Statistical theory and methodology in science and engineering, 2. ed. New York: J. Wiley and Sons 1965.
Burck, H. C.: Histologische Technik. Stuttgart: G. Thieme 1966.
Eccles, J. C., Sherrington, C. S.: Numbers and contraction values of individual motor-units examined in some muscles of the limb. Proc. roy. Soc. B 106, 326–357 (1930).
Fernand, V. S. V., Young, I.: The size of the nerve fibres of muscle nerves. Proc. roy. Soc. B 139, 38–58 (1951–1952).
Gasser, H. S., Grundfest, H.: Axon diameters in relation to the spike dimensions and the conduction velocity in mammalian A-fibers. Amer. J. Physiol. 127, 393–414 (1939).
Gentele, H., Swensson, A.: Über die Kaliberverhältnisse der hinteren Rückenmarkswurzeln beim Menschen. Z. mikr.-anat. Forsch. 50, 190–206 (1941).
Häggqvist, G.: Nervenfaserkaliber bei Tieren verschiedener Größe. Anat. Anz. 96, 398–412 (1947 1948).
Michailow, S.: Über die Gesetzmäßigkeiten des inneren Baues der peripheren Nerven. Anat. Anz., Erg. z. 121, 261–275 (1968).
Pearse, E.: Histochemistry, 2nd ed. London: Churchill 1961.
Rexed, B.: Contributions to the knowledge of the postnatal development of the peripheral nervous system in man; study of the basis and scope of systematic investigations into fibre size in peripheral nerves. Acta psychiat. (Kbh.), Suppl. 33, 1–206 (1944).
Romeis, B.: Mikroskopische Technik, 16. neubearb. und verb. Aufl. München-Wien: R. Oldenbourg 1968.
Sabatini, D. R., Bensch, Kl., Barrnett, R. J.: Cytochemistry and electron microscopy. The preservation of cellular ultrastructure and enzymatic activity by aldehyde fixation. J. Cell Biol. 17, 19–58 (1963).
Sanders, F. K.: The thickness of myelin sheaths of normal and regenerating peripheral nerve fibres. Proc. roy. Soc. B 135, 323–357 (1948).
—, Whitteridge, D.: Conducting velocity and myelin thickness in regenerating nerve fibers. J. Physiol. (Lond.) 105, 152–174 (1946).
Schnepp, P., Schnepp, G.: Faseranalytische Untersuchungen an peripheren Nerven bei Tieren verschiedener Größe. II. Verhältnis Axondurchmesser/Gesamtdurchmesser und Internodallänge. Z. Zellforsch. 119, 99–114 (1971).
Schuchardt, E.: Maßzahlen über Achsenzylinder und Markscheide markhaltiger Nervenfasern des Kaltblütlers. Messungen am N. ischiadicus von Rana esculenta. Arch. Psychiat. Nervenkr. 179, 451–457 (1948).
Schwarzacher, H. G.: Markscheidendicke und Achsenzylinderdurchmesser im peripheren menschlichen Nerven. Acta anat. (Basel) 21, 26–46 (1954).
Sherrington, C. S.: On the anatomical constitution of nerves of skeletal muscles; with remarks of recurrent fibers in the ventral spinal nerve root. J. Physiol. (Lond.) 17, 211–258 (1894).
Spaan, G., Schnepp, G., Schnepp, P., Oksche, A., Klussmann, F. W.: Nervenleitungsgeschwindigkeit, Faserdicke und Internodallänge myelinisierter Nerven bei Tierarten verschiedener Größe. Demonstration auf der 36. Tag der deutschen Physiologischen Gesellschaft vom 23.–27. 9. (1969), s. Pflügers Arch. 312, 152 (1969).
Stoehr, Ph., jr.: Die peripherische Nervenfaser. In: Handbuch der mikroskopischen Anatomie des Menschen. Bd. IV/1 (Hrsg. W. v. Möllendorff), p. 158. Berlin: Springer 1928.
Stoffel, A.: Beiträge zu einer rationellen Neurochirurgie. Münchn. med. Wschr. 4, 175–179 (1913).
Sunderland, S., Lavarack, J. O.: The branching of nerve fibers. Acta anat. (Basel) 17, 46–61 (1953).
— Ray, L. J.: The caliber of nerve fibers in human cutaneous nerves. J. comp. Neurol. 91, 87–101 (1949).
—, Ray, L. J.: The intraneural topography of the sciatic nerve and its popliteal divisions in man. Brain 71, 242–273 (1948).
Tatesi, S.: Zit. nach Fernand and Young. (1940).
Taylor, G. W.: The correlation between sheath birefringence and conduction velocity with special reference to cat nerve fibers. J. cell. comp. Physiol. 20, 359 (1942).
Tomasch, J., Schwarzacher, H. G.: Die innere Struktur peripherer menschlicher Nerven im Lichte faseranalytischer Untersuchungen. Acta anat. (Basel) 16, 315–354 (1952).
Wasano, T., Tagawa, T., Uehara, Y., Oda, K., Miyake, A., Okabe, T., Koga, S.: Fiber analytical studies on the peripheral motor nerves. Kyushu J. med. Sci. 13, 1–22 (1962).
Wohlfart, G.: Über den inneren Bau der peripheren Nervenstämme. Z. mikr.-anat. Forsch. 43, 191–206 (1938).
Author information
Authors and Affiliations
Additional information
Arbeit unter Leitung von Prof. Dr. A. Oksche, Gießen, und Priv.-Doz. Dr. F. W. Kluß mann, Bad Nauheim.
Mit Unterstützung durch die Deutsche Forschungsgemeinschaft.
Teil einer medizinischen Doktorarbeit.
Rights and permissions
About this article
Cite this article
Schnepp, G., Schnepp, P. & Spaan, G. Faseranalytische Untersuchungen an peripheren Nerven bei Tieren verschiedener Größe. Z. Zellforsch. 119, 77–98 (1971). https://doi.org/10.1007/BF00330540
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00330540