Iodide and xenon enhancement of computed tomography (CT) in multiple sclerosis (MS)

  • Originals
  • Published:
Neuroradiology Aims and scope Submit manuscript

Summary

The characteristic findings on computed tomography (CT) in multiple sclerosis (MS) are discussed. In a series of 49 cases plain CT was normal in 21 (43%), cerebral atrophy alone was present in 17 (35%) and plaques were visible in 11 (23%). These were most often adjacent to the lateral ventricles (14 plaques) and in the parietal white matter (10 plaques).

CT was performed after the intravenous administration of iodide in 16 of these cases. Three of the low attenuation and three additional isodense lesions enhanced. Two patients with low attenuation plaques were scanned with xenon enhancement; the plaques absorbed less xenon than the corresponding contralateral brain substance and additional, previously isodense plaques were revealed. In one case the white matter absorbed much less xenon than normal and its uptake relative to grey matter was reduced.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Broman, T.: Blood-brain barrier damage in multiple sclerosis supra-vital test observations. Acta neurol. (Scand.) 40, Supplement 10, 21–24 (1964)

    Google Scholar 

  2. Brownell, B., Hughes, J.T.: The distribution of plaques in the cerebrum in multiple sclerosis. J. Neurol. Neurosurg. Psychiat. 25, 315–320 (1962)

    Google Scholar 

  3. Cole, M., Ross, J.R.: Plaque of multiple sclerosis seen on computerized axial tomogram. Neurology (Minneapolis) 27, 890–891 (1977)

    Google Scholar 

  4. Cullen, S.C., Gross, E.G.: Anesthetic properties of Xenon and Krypton. Science 113, 580–582 (1951)

    Google Scholar 

  5. Gyldensted, C.: Computer tomography of the cerebrum in multiple sclerosis. Neuroradiology 12, 33–42 (1976)

    Google Scholar 

  6. Huckman, M.S., Fox, J.H., Ramsey, R.G.: Degenerative disease of the brain. Computed cranial tomography. Semin. Roentgenol. 12, 61–73 (1977)

    Google Scholar 

  7. Jacobs, L., Kinkel, W.R.: Computerized axial tomography in multiple sclerosis. Neurology (Minneapolis) 26, 390–391 (1976)

    Google Scholar 

  8. Lumsden, C.E.: The neuropathology of multiple sclerosis. Handbook of Clinical Neurology 9, 217–309. (Ed. Vinken, P.J., Bruyn, G.W.). Amsterdam: North Holland 1970

    Google Scholar 

  9. McIlwain, H., Buchclard, H.S.: Biochemistry and the central nervous system, pp. 371–385. London: Churchill Livingstone 1971

    Google Scholar 

  10. Winkler, S.S., Sackett, J.F., Holden, J.E., Fleming, D.C., Alexander, S.C., Madsen, M., Kimmel, R.I.: Xenon inhalation as an adjunct to computerized tomography of the brain. Preliminary study. Invest. Radiol. 12, 15–18 (1977)

    Google Scholar 

  11. Wüthrich, R., Gigli, H., Wiggli, U., Muller, H.R., Elke, M., Hunig R.: C.T. scanning in demyelinating disease in cranial computerised tomography, pp. 239–243 (Ed. Lanksch and Kazner). Berlin, Heidelberg, New York: Springer 1976

    Google Scholar 

  12. Zilkha, E., Ladurner, G., Iliff Linnette D., du Boulay, G.H., Marshall, J.: Computer subtraction in regional cerebral bloodvolume measurements using the EMI scanner (ab)

Download references

Author information

Authors and Affiliations

Authors

Additional information

EMI Research Fellow

Rights and permissions

Reprints and permissions

About this article

Cite this article

Radue, E.W., Kendall, B.E. Iodide and xenon enhancement of computed tomography (CT) in multiple sclerosis (MS). Neuroradiology 15, 153–158 (1978). https://doi.org/10.1007/BF00329059

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00329059

Key words

Navigation