Skip to main content
Log in

Background correction in frequency modulated simultaneous atomic absorption spectrometry

  • Original Papers
  • AAS, Evaluation
  • Published:
Fresenius' Journal of Analytical Chemistry Aims and scope Submit manuscript

Summary

For a long time simultaneous multielement determination by AAS has been a subject of intensive research. In this work a simultaneous multielement atomic absorption spectrometry method is described in a special new arrangement, called frequency modulated simultaneous AAS (FremsAAS), using fiberoptics, interference filters and frequency modulation and demodulation by lock-in amplifiers as main devices. Purpose of this work was to equip the FremsAAS with a D2-background correction and to test it with certified reference materials. Mn, Cd, Pb, Cu, Ni, Cr and Zn had been determined simultaneously (three at a time) in sewage sludge (BCR/CRM 146), estuarine sediment (BCR/CRM 277) and phosphate rock (BCR/CRM 32) with good feasibility. Frequency modulated simultaneous AAS with background correction (FremsAASUK) represents an interesting alternative to known instruments.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Winter F, Quick L, Bradter M, Cammann K (1991) Frequenzselektive simultane Multielement AAS. In: Welz B (ed) 6. Coloquium Atomspektrometrische Spurenanalytik. Bodenseewerk Perkin Elmer GmbH, Überlingen

    Google Scholar 

  2. Winter F (1991) thesis Westfälische Wilhelms-Universität Münster

  3. (1988) BCR-Report EUR 11850 EN, Brüssel, Ispra

  4. (1983) BCR-Report EUR 8838 EN, Brüssel, Ispra

  5. (1983) BCR-Report EUR 8537 EN, Brüssel, Ispra

  6. Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlammuntersuchung, Bd III, VCH, Weinheim, S7

  7. (1987) Gerätehandbuch AAS 1100. Perkin Elmer GmbH Bodenseewerk, Überlingen

  8. Doerffel K (1987) Statistik in der analytischen Chemie, 4. Auflage. VCH, Weinheim

    Google Scholar 

  9. (1981) Firmenschrift, Fa. Instrumentation Laboratory; Bornheim

  10. Schmeling M (1992) diplom thesis Westfälische Wilhelms-Universität Münster

Download references

Author information

Authors and Affiliations

Authors

Additional information

Dedicated to Prof. Dr. V. Krivan on the occasion of his 60th birthday

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lehnert, R., Quick, L., Rump, T. et al. Background correction in frequency modulated simultaneous atomic absorption spectrometry. Fresenius J Anal Chem 346, 392–395 (1993). https://doi.org/10.1007/BF00325849

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00325849

Keywords

Navigation