Summary
The preparation of the bovine liver 12-02-01 reference material, its stabilization and homogeneity testing is presented. Evaluation of an interlaboratory comparison in which 31 laboratories took part using several analytical methods is described. From the results of the intercomparison, the contents of the elements Cd, Cu, Hg, Mn, Pb, Se, and Zn were certified, while for the elements Br, Co, Fe, K, Mo, Na, and Rb, information values were derived. Non-recommended values for the elements Ag, As, Ca, Cl, Cr, Cs, La, Mg, S, Sb, Sn, Sr, and V were also evaluated.
Similar content being viewed by others
References
Muramatsu Y, Parr RM (1985) Survey of currently available reference materials for use in connection with the determination of trace elements in biological and environmental materials. IAEA/RL/128, Vienna
Gladney ES, O'Malley BT, Roelandts I, Gills TE (1987) Standard reference materials: compilation of elemental concentrations data for NBS clinical, biological, geological, and environmental standard reference materials. NBS Spec. Pub, p 260–111, Gaithersburg
Wagstaffe PJ, Hecht H, Muntau H, Schramel P (1987) Fresenius Z Anal Chem 329:475
Mader P, Kučera J, Cibulka J, Miholová D (1989) Chem Listy 83:765
Kučera J, Soukal L (1988) J Radioanal Nucl Chem Articles 121:245
Kučera J, Mader P, Miholová D, Cibulka J, Poláková M, Kordík K (1989) Report on the interlaboratory comparison of the determination of the content of trace elements in bovine liver 12-02-01, Czechoslovak Institute of Metrology, Bratislava
Püschel P, Formánek Z, Vlasáková, Stuchlíková A (1988) Proc. 3th Czechoslovak Spectroscopic Conference, České Budějovice, June 19–24
Püschel P, Formánek Z, Vlasáková A, Stuchlíková A (1988) Proc X. CANAS, September 5–9
Trace mercury analyzer TMA 254, information leaflet, the science and research section of the Prague institute of chemical technology, Prague
Hlaváč R, Doležal J, Kolihová D, Sychra V, Pietroš L, Valenta S, Püschel P, Formánek Z (1985) Proc. XIV CSI, Garmisch-Partenkirchen, September
Dybczynski R (1980) J Radioanal Chem 60:45
Kučera J (1989) Radioisotopy 30:195
Eckschlager K, Horsák I, Kodejš Z (1980) Vyhodnocování analytických výsledk∪ a metod. SNTL, Praha
Shapiro SS, Wilk MB (1965) Biometrika 52:591
Dybczynski R (1980) Anal Chim Acta 117:53
Davies PL (1988) Fresenius Z Anal Chem 331:513
Sachs L (1982) Applied statistics, a handbook of techniques. Springer, Berlin Heidelberg New York
Griepink B, Colinet E, Gonska H, Muntau H (1984) Report EUR 9251 EN, Community Bureau of Reference. CEC, Brussels
Marchandise H, Colinet E (1983) Fresenius Z Anal Chem 316:669
Certificate of analysis for standard reference material 1577, bovine liver (1977) NBS, Washington, Revision 14 June
Certificate of analysis of standard reference material 1577a, bovine liver (1985) NBS, Gaithersburg, February
Czechoslovak state norm (1964) ČSN 01 2801, Vydavatelství ÚNM, Prague
Toro EC, Parr RM, Clements SA (1990) IAEA/RL/128 (RV.1), Vienna
Author information
Authors and Affiliations
Additional information
Denoted as CZIM-liver in the report [23]
Rights and permissions
About this article
Cite this article
Kučera, J., Mader, P., Miholová, D. et al. Preparation of the bovine liver 12-02-01 reference material and the certification of element contents from an interlaboratory comparison. Fresenius J Anal Chem 338, 66–71 (1990). https://doi.org/10.1007/BF00322788
Received:
Issue Date: