Skip to main content
Log in

The physical performances of a single slice positron tomographic system and preliminary results in a clinical environment

  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Metabolic phenomena can be studied and measured non-invasively using positron emitting radionuclides and a suitably adapted tomographic system. The choice of a single slice ring camera is justified by its physical performance, which is presented here and discussed. A series of measurements with geometrical phantoms and analytical simulations have been performed to determine the critical characteristics of the system. This has permitted optimization of certain parameters enabling very interesting clinical results to be obtained at SHFJ, particularly in the area of cerebral physiopathology.

In addition, the potential of obtaining absolute quantitative values of regional activity is presented. The calibration of the system, spatial non-stationarities, and attenuation correction, which represent the main sources of error, are considered in detail.

A precision of the order of 10% should be obtainable. Such a quantitation method has been successfully applied to the in vivo study of the regional extraction of cerebral oxygen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Baron, J.C., Comar, D., Bousser, M.G., Soussaline, F., Crouzel, C., Kellershohn, C., Castaigne, P.: Etude tomographique chez l'homme, du débit sanguin et de la consommation d'oxygène du cerveau par inhalation continue d'oxygène 15. Rev. Neurol. (Paris) 134, 545–556 (1978)

    CAS  Google Scholar 

  • Berger, G., Mazière, M., Marazano, C., Comar, D.: Carbon 11 labelling of the psychoactive drug O-methyl-bufornine and its distribution in the animal organism. Eur. J. Nucl. Med. 3, 101–104, (1978)

    Article  CAS  PubMed  Google Scholar 

  • Brownell, G.L., Burnham, C.A., Wilensky, S., Aronow, S., Kazemi, S., Strieder, D.: New Developments in positron scintigraphy and the application of cyclotron produced positron emitters. Medical radioisotope scintigraphy, Proc. Symp. Salzburg (1968) 1, pp. 163–176. Vienna: IAEA 1968

    Google Scholar 

  • Brownell, G.L., Burnham, C.A.: In: Tomographic imaging in nuclear medicine, Friedman, G.S. (ed), pp 154–164. New York: Society of Nuclear Medicine 1973

    Google Scholar 

  • Brownell, G.L., Burnham, C.A., Hoop, B.Jr.,: Positron scintigraphy with short-lived cyclotron produced radiopharmaceuticals. In: Medical radioisotope scintigraphy, 1, 313–330, Vienna: IAEA 1973

    Google Scholar 

  • Budinger, T.F., Derenzo, S.E., Greenberg, W., Gullberg, G.T., Huesman, R.H.: Quantitative potentials of dynamic emission computed tomography. J. Nucl. Med., 19, 309–315 (1978)

    CAS  PubMed  Google Scholar 

  • Cho, Z.H., Cohen, M.B., Singh, M.: Performance and evaluation of the circular ring transverse axial positron camera (CRTAPC). IEEE Nucl. Sci. NS 24, 530–543, (1977)

    Google Scholar 

  • Comar, D., Mazière, M., Berger, G., Mestelan, G.: Quelques exemples de l'intérêt des molécules marquées au 11C en recherche médicale. BIST 220, 19–26 (1976)

    CAS  Google Scholar 

  • Crouzel, C., Comar, D., Berger, G., Mazière, M., Soussaline, F., Todd-Pokropek, A.E., Baron, J.C., Guenard, H., Verhas, M.: First clinical results using short lived radioisotopes produced by a medical cyclotron. In: VIIIth Int. Conf. on Cyclotrons and their medical applications. Bloomington: 1978

  • Derenzo, S.E., Budinger, T.F., Camoon, J.L.: High resolution computed tomography of positron emitters. IEEE Nucl. Sci. NS 24, 544–558 (1977)

    Article  Google Scholar 

  • Derenzo, S.E., Zaklad, H., Budinger, T.F.: Analytical study of a high resolution positron ring detector system for transaxial reconstruction tomography. J. Nucl. Med. 16, 1166–1173 (1975)

    CAS  PubMed  Google Scholar 

  • Jones, T., Chesler, D.A., Ter-Pogossian, M.M.: The continuous inhalation of oxygen 15 for assessing regional oxygen extraction in the brain of man. Br. J. Radiol. 49, 339–343 (1976)

    Article  CAS  PubMed  Google Scholar 

  • Lim, C.K., Chu, D., Kaufman, L.: Initial characterization of a multiwire proportional chamber positron camera. IEEE Nucl. Sci. NS 22, 388–394 (1975)

    Article  Google Scholar 

  • Muehllehner, G., Buchin, N.P., Dubek, G.H.: Performance parameters of the positron imaging camera. IEEE Nucl. Sci. NS 23, 528–537 (1976)

    Article  Google Scholar 

  • Phelps, M.E., Hoffman, E.J., Kuhl, D.E.: Physiologic tomography: A new approach to in vivo measure of metabolism and physiological function. In: Medical radionuclide imaging, 1, 233–253, Vienna: IAEA 1977

    Google Scholar 

  • Phelps, M.E., Hoffman, E.J., Mullani, N.: Design and performance characteristics of a whole body transaxial tomograph. (PETT III). IEEE Nucl. Sci. 23, 516–522 (1976)

    Article  Google Scholar 

  • Phelps, M.E., Hoffman, E.J., Mullani, N.: Design and performance characteristics of a whole body transaxial tomograph. J. Nucl. Med 17, 493–502 (1976)

    PubMed  Google Scholar 

  • Phelps, M.E., Hoffman, E.J., Huang, S.C., Kuhl, D.E.: ECAT a new computerized tomographic imaging system for positronemitting radiopharmaceuticals. J. Nucl. Med. 19, 635–647 (1978)

    CAS  PubMed  Google Scholar 

  • Shepp, L.A., Logan, B.F.: Some insights into the Fourier reconstruction of a head section. IEEE Nucl. Sci. NS 21, 21–43 (1974)

    Article  Google Scholar 

  • Syrota, A., Comar, D., Cerf, M., Plummer, D., Mazière, M., Kellershohn, C.: 11C-Methionine pancreatic scanning with positron emission computed tomography. J. Nucl. Med. (in press) (1979)

  • Ter-Pogossian, M.M., Phelps, M.E., Brownell, G.L.: Reconstruction tomography in diagnostic radiology and nuclear medicine. Baltimore: University Park Press 1977

    Google Scholar 

  • Ter-Pogossian, M.M., Phelps, M.E., Hoffman, E.J.: A positron emission transaxial tomograph for nuclear medicine imaging (PETT). Radiology 114, 89–98 (1975)

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Soussaline, F., Todd-Pokropek, A.E., Plummer, D. et al. The physical performances of a single slice positron tomographic system and preliminary results in a clinical environment. Eur J Nucl Med 4, 237–249 (1979). https://doi.org/10.1007/BF00304879

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00304879

Keywords

Navigation