The parameters affecting the determination of some heavy metals in rainwater of Florence and its suburbs are investigated The maximum sensitivity for zinc determination by DPASV is obtained for a pulse amplitude of +50 mV.

Samples of rainwater, collected in the center of Florence, show a metal concentration which is higher than samples collected in the suburb for the same meteorological event. Other sampling along the Tyrrenean seashore revealed a higher metal concentration in relation to the section of the coast that receives the polluted waters of the Arno river.

In samples acidified to pH = 2, Cu and Zn are partially released in a very slow process.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Baston, W. and Nana, A.: 1974, Boll. Lab. Chim. Prov. 25, 180.

    Google Scholar 

  • Beneš, P., Koe, J., and Štulik, K.: 1979, Water Res. 13, 967.

    Google Scholar 

  • Dillard, J. W. and Hauck, K. W.: 1976, Anal. Chem. 48, 218.

    Google Scholar 

  • Florence, T. M. and Batley, G. E.: 1977, J. Electroanal. Chem. 75, 791.

    Google Scholar 

  • Fusari, R., Murri, A., and Scuterini, C.: 1974, Inquinamento 16, 16.

    Google Scholar 

  • Liberti, A., Brocco, D., and Canuti, V.: 1974, Inquinamento 16, 12.

    Google Scholar 

  • Li Ta-Yung and Landsberg, H. E.: 1975, Atmospheric Environment 9, 81.

    Google Scholar 

  • Nucciotti, F., Simonini, G., and Vittori, O.: 1968, Riv. Meteorol. Aeron. 23, 1.

    Google Scholar 

  • Pantani, F., Cellini-Legittimo, P., Racanelli, R., and Sigg, G.: 1977, Inquinamento 19, 51.

    Google Scholar 

  • Parry, E. P. and Osteryoung, R. A.: 1965, Anal. Chem. 37, 1634.

    Google Scholar 

  • Shuman, M. S. and Woodward, G. P.: 1976, Anal. Chem. 48, 1979.

    Google Scholar 

  • Štráfelda, F. and Kimla, A.: 1963, Collection Czech. Chem. Commun. 28, 1516.

    Google Scholar 

  • Struempler, A. W.: 1975, Environ. Sci. Technol. 9, 1164.

    Google Scholar 

  • Wright, R. F. and Gjessing, E. T.: 1976, Ambio 5, 219.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Legittimo, P.C., Piccardi, G. & Pantani, F. Cu, Pb and Zn determination in rainwater by differential pulse anodic stripping voltammetry. Water Air Soil Pollut 14, 435–441 (1980). https://doi.org/10.1007/BF00291856

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00291856

Keywords

Navigation