Skip to main content

Advertisement

Log in

The external fixateur in the management of unstable colles' fracture

  • Published:
International Orthopaedics Aims and scope Submit manuscript

Summary

Colles' fracture is frequently unstable with a high incidence of redisplacement, varying from 40–60% in various published series. Redisplacement following reduction can be avoided with a small external fixateur using two pins placed at right angles to each other both in the distal fragment and the radial shaft. This technique has been employed in twenty-two patients with secondary displacement of Colles' fracture and the end results evaluated by the McBridge points system was excellent or good in twenty-one of the twenty-two patients.

Résumé

Les fractures de l'extrémité inférieure du radius sont souvent instables, d'où un pourcentage important de déplacement itératif, variant, selon les séries publiées, de 40 à 60%. Ce redéplacement après réduction peut être évité grâce à l'utilisation d'un petit fixateur externe, dont deux fiches sont placées perpendiculairement l'une à l'autre dans le fragment distal et deux autres dans la diaphyse. Cette technique a été utilisée chez 22 blessés présentant un déplacement secondaire après réduction d'une fracture de Pouteau-Colles. Les résultats, évalués selon la cotation de Mc Bride, ont été bons ou excellents dans 21 cas sur 22.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bacorn, R. W., Kurzke, F. J.: Colles' fracture: a study of two thousand cases. J. Bone Joint Surg. 35, 643–658 (1953)

    Google Scholar 

  2. Böhler, L.: Technik der Knochenbruchbehandlung. Wienna, Maudrich, 1937

    Google Scholar 

  3. Cartier, P., Tiesse, J., Pere, Ch.: Traitement des fractures comminutives du poignet par la méthode de traction bipolaire. Rev. Chir. Orthop. 61, 517–531 (1975)

    Google Scholar 

  4. Cole, J. M., Obletz, B. E.: Comminuted fractures of the distal end of the radius treated by skeletal transfixation in plaster cast. J. Bone Joint Surg. [Am.] 48, 931–945 (1966)

    Google Scholar 

  5. Cooney, W. P., Linscheid, R. L., Dobyns, J. H.: External pin fixation for unstable Colles' fractures. J. Bone Joint Surg. [Am]. 61, 840–845 (1979)

    Google Scholar 

  6. Dowling, J. J., Sawyer, B. Jr.: Comminuted Colles' fractures. Evaluation of a method of treatment. J. Bone Joint Surg. [Am.] 43, 657–668 (1961)

    Google Scholar 

  7. Fernandez, D. L., Albrecht, H. H., Sachs U.: Die Korrektureosteotomien am distalen Radius bei posttraumatischer Fehlstellung. Arch. Orthop. Unfallchir. 90, 199–205 (1974)

    Google Scholar 

  8. Frykmann, G.: Fracture of the distal radius including sequale shoulder-hand-finger syndrome. Acta Orthop. Scand., Suppl. 108 (1967)

  9. Gartland, J. J. Jr., Werley C. W.: Evaluation of healed Colles' fractures. J. Bone Joint Surg. [Am.] 33, 895–907 (1951)

    Google Scholar 

  10. Heim, U.: Die gelenknahen Speichenbrüche des Erwachsenen. Unfallheilkunde 82, 15–22 (1979)

    Google Scholar 

  11. Koch, E.: Die handgelenknahen Speichenbrüche im Erwachsenenalter. Orthopädie 4, 14–18 (1975)

    Google Scholar 

  12. Lanz, U., Kron, W.: Neue Technik zur Korrektur in Fehlstellung verheilter distaler Radiusfrakturen. Handchirurgie 8, 203–206 (1976)

    Google Scholar 

  13. McBride, E. D.: Disability evaluation. Principles of treatment of compensable injuries. J. B. Lippincott Co., Philadelphia, 1948

    Google Scholar 

  14. Müller-Färber, J., Griebel, W.: Der sekundäre Korrektureingriff am distalen Radius bei posttraumatischer Fehlstellung. Unfallheilkunde 82, 23–28 (1979)

    Google Scholar 

  15. Rauis, A., Ledoux, A., Thiebaut, A., Ghinst, M.: Bipolar fixation of fractures of the distal end of the radius. Clin. Orthop. (SICOT) 3, 89–96 (1979)

    Google Scholar 

  16. Roth, B., Müller, J., Lusser, G., Bartone, C., Bachmann, B.: Erfahrungen mit perkutanen Spickdrahtosteosynthese. Helv. Chir. Acta 44, 815–821 (1977)

    Google Scholar 

  17. Stockmann, U., Birnbaum, D., Büssig, E. W., Hepp, W., Lippe, B., Zuschneid, W.: Die Problematik der distalen Radiusfraktur aus der Sicht des Patienten. Unfallheilkunde 79, 71–74 (1976)

    Google Scholar 

  18. Willenegger, H., Guggenbühl, A.: Zur operativen Behandlung bestimmter Fälle von distalen Radiusfrakturen. Helv. Chir. Acta 26, 81–85, (1959)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Forgon, M., Mammel, E. The external fixateur in the management of unstable colles' fracture. International Orthopaedics 5, 9–14 (1981). https://doi.org/10.1007/BF00286093

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00286093

Key words

Navigation