Skip to main content
Log in

An analytical correction for peak broadening in gel permeation chromatography with a molecular weight detector

  • Published:
Polymer Bulletin Aims and scope Submit manuscript

Summary

In this paper we present a general expression describing the peak broadening effect on molecular weight averages measured during the elution of a polymer in GPC. This expression is valid for nonlinear column calibration and nonuniform Gaussian spreading across the chromatogram. Comparison is made with analytical relationships derived by Yau, Marais, Hamielec and Netopilik. The methodology developed as an extension of the Pierce and Armonas method is applied to a model system and to elution data of dextrans.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Tung, L.H., J.Appl.Polym.Sci., 10, 375 (1966).

    Google Scholar 

  2. Yau, W.H., Stoklosa, H.J., Bly, D.D., J.Appl.Polym.Sci., 21, 1911 (1977).

    Google Scholar 

  3. Marais, L., Gallot, Z., Benoît, H., J.Appl.Polym.Sci., 21, 1955 (1977).

    Google Scholar 

  4. Hamielec, A.E., J.Liquid Chromatogr., 3., 381 (1980).

    Google Scholar 

  5. Hamielec, A.E., Ederer, H.J., Ebert, K.H., J.Liquid Chromatogr., 4, 1697 (1981).

    Google Scholar 

  6. Kim, C.J., Hamielec, A.E., Benedek, A., J.Liquid Chromatogr., 5, 425 (1982).

    Google Scholar 

  7. Hamielec, A.E., in “Steric Exclusion Liquid Chromatography of Polymers”, Chromatographic Science Series, 25, 117 (1984) edited by J.Janca, Marcel Dekker INC 1984.

    Google Scholar 

  8. Pierce, P.E., Armonas, J.E., J.Polym.Sci., C21, 23 (1968).

    Google Scholar 

  9. Netopilik, M., Polym.Bull., 10, 478 (1983).

    Google Scholar 

  10. Van Dijk, J.A.P.P., Varkevisser, F.A., Smit, J.A.M., J.Polym.Sci., Polym.Phys.Ed., 25, 149 (1987).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Eggink, G., van Dijk, J.A.P.P. & Smit, J.A.M. An analytical correction for peak broadening in gel permeation chromatography with a molecular weight detector. Polymer Bulletin 17, 531–538 (1987). https://doi.org/10.1007/BF00283089

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00283089

Keywords

Navigation