Abstract
Fifty two patients with visualization of one lobe or one lobe with faint active thyroid tissue in the region of the other lobe on thyroid scintigraphy, were studied using shielding of the active thyroid tissue in order to visualize the rest of the gland. This technique is useful in the differential diagnosis of autonomous nodules without need for the time consuming, costly, and sometimes hazardous TSH stimulation and T3 suppression tests. Furthermore, this technique could be used to verify total lobectomy in patients following thyroid surgery. Further work to differentiate congenital thyroid hemiagenesis from non toxic sutonomous nodules is suggested.
Similar content being viewed by others
References
Alderson PO, Summer HW, Siegel BA (1976) Single palpable thyroid nodule. Evaluation by Tc-99m pertechnetate imaging. Cancer 37:258–265
Al-Saadi AS, Turaihi KS, Khazar Jain AK, Al-Hindawi AY (1981) Thyroid hemiagenesis. Nuclear medicine communication. Vol. 2:170–173
Atkin HL (1971) Technetium-99m pertechnetate uptake and scanning in the evaluation of thyroid function. Sem Nucl Med 1:345–355
Atkins III, Richards (1968) Assessment of thyroid function and anatomy with technetium 99m as pertechnetate. J Nucl Med 9:7–15
Blum M (1986) Imaging in the management of thyroid nodules; A personal perspective. Thyroid today-Vol I X, No. 1, Jan/Feb/March
Blum M (1978) Management of the solitary thyroid nodule. A selective approach. Thyroid today Vol. 1, No 9 July
Charkes ND (1971) Scintigraphic evaluation of nodular goitre. SNM 1:316–333
Dodds WJ, Powell MR (1968) Thyroid scanning with technetium99m pertechnetate. Radiology 91:27–31
Erjavec M, Movrin T, Auersperg M, Golouch R (1977) Comparative accumulation of Tc99m and I131 in thyroid nodules (case report) J Nucl Med 18:346–347
Hamburger JI, Hamburger SW (1970) Thyroid hemiagenesis—Report of case and comments on clinical ramifications. Arch Surg 160:319
Harper PV, Lathrop KA, Jiminez F, Fink R, Gottschalk A (1965) Technetium-99m as a scanning agent. Radiology 85:101–109
Hoffer PB, Marks W (1978a) Discrepant function in thyroid nodule. In: Syllabus-Theros EG (ed) Nuclear radiology (second series) Waverly Press, Chicago ACR, p 576
Hoffer PB, Marks W (1978b) Iodine 123 versus iodine 131 for thyroid imaging. In: Syllabus-Theros EG (ed) Nuclear radiology (second series). Waverly Press, Chicago ACR, p 579
Quaife MA, Nage MV, Kotlyarov EV (1981) The endocrine system. In: Bernier DR, Langan JK, Wells LD (eds) Nuclear Medicine Technology and Techniques. Mosby, St Louis, pp 248–249
Rienser CAII, Isley WI (1985) Thyroid scanning in patients with suspected thyroid disease. Ann Intern Med 102:209–210
Ryo Y, Arnold J, Coleman M, Arnold A, Favuf M, Frohman L, Schneider A, Stachura M, Pinsky F (1976) Thyroid scintigram sensitivity with sodium pertechnetate Tc-99m and gamma camera with pinhole collimator. Jama 235:1235–1238
Straus HW, Hurley PJ, Wagner HN Jr (1970) Advantage of Tc99m pertechnetate for thyroid scanning in patients with decreased radioiodine uptake. Radiology 97:307–310
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Al-Eid, M.A., Al-Attar, R.A. & Al Hindawi, A.Y. Clinical utility of a simple physical technique in thyroid scintigraphy. Eur J Nucl Med 13, 443–445 (1987). https://doi.org/10.1007/BF00281857
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00281857