Quantitative immunofluorescence

Standardization and calibration in microfluorometry

  • Published:
Histochemie Aims and scope Submit manuscript

Summary

Instrumental requirements for quantitative immunofluorescence were analyzed. Commercially available equipment was found to be sufficiently sensitive and light sources such as a halogen lamp and the 75 W xenon high pressure arc lamp were found not to fluctuate more than one percent if operated on a stabilized power supply. Only minor modifications of the instrumentation were needed to obtain readings with a reproducibility within one percent, provided the environmental temperature was kept constant. A uranyl glass slide proved to be a suitable calibration standard, to be used for each series of measurements. As standard fluorescein unit (SFU) 10−3 of the fluorescence of 1 picoliter of a 50 μM fluorescein solution pH 8.5 was chosen. The pH of fluorescein dyes had to be about 8.5 since the fluorescence was then maximal and the influence of small pH variations neglectable. The SFU was measured either from microdroplets of fluorescein solution or in microcapillaries containing this solution. The microcapillary system is to be preferred since it is easier to handle, measurements are less time consuming and fading is less disturbing the measurements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Böhm, N., Sprenger, E.: Fluorescence cytophotometry: A valuable method for the quantitative determination of nuclear Feulgen-DNA. Histochemie 16, 100–118 (1968).

    Google Scholar 

  • Boileau, A. R., Miller, F. D.: Changes in spectral sensitivity of multiplier phototubes resulting from changes in temperature. Appl. Opt. 6, 1179–1182 (1967).

    Google Scholar 

  • Cherry, W. B.: Fluorescence emission with special reference to standardization in immunofluorescence. In: Standardization in immunofluorescence, ed. by E. J. Holborow, p. 127–136. Oxford-Edinburgh: Blackwell Scientific Publications 1970.

    Google Scholar 

  • Emmart, E. W.: Observations on the absorption spectra of fluorescein, fluorescein derivates and conjugates. Arch. Biochem. 73, 1–8 (1958).

    Google Scholar 

  • Goldman, M.: Antigenic analysis of Entamoeba histolytica by means of fluorescent antibody. I. Instrumentation for microfluorimetry of stained amebae. Exp. Parasit. 9, 25–36 (1960).

    Google Scholar 

  • — An improved microfluorimeter for measuring brightness of fluorescent antibody reactions. J. Histochem. Cytochem. 15, 38–45 (1967).

    Google Scholar 

  • Goldwasser, R. A., Shepard, C. C.: Staining of complement and modifications of fluorescent antibody procedures. J. Immunol. 80, 122–131 (1958).

    Google Scholar 

  • Hijmans, W., Schuit, H. R. E., Jongsma, A. P. M., Ploem, J. S.: Performance testing of fluorescent antisera against human immunoglobulins. In: Standardization in immunofluorescence, ed. by E. J. Holborow, p. 193–202. Oxford-Edinburgh: Blackwell Scientific Publications 1970.

    Google Scholar 

  • Hiramoto, R., Bernecky, J., Jurand, J., Hamlin, M.: The effect of hydrogen ion concentration on fluorescent labelled antibodies. J. Histochem. Cytochem. 12, 271–274 (1964).

    Google Scholar 

  • Irvine, W. J., Chan, M. M. W., Williamson, W. G.: The application of microphotometry to the indirect immunofluorescent antibody technique using the human gastric parietal cell antigen-antibody system. Clin. exp. Immunol. 4, 607–617 (1969).

    Google Scholar 

  • McKinney, R. M., Spillane, J. T., Pearce, G. W.: Fluorescein diacetate as a reference color standard in fluorescent antibody studies. Ann. Biochem. 2, 474–476 (1964).

    Google Scholar 

  • Nairn, R. C.: Fluorescence microscopy and photomicrography. In: Fluorescent protein tracing, ed. by R. C. Nairn, p. 60–87. Edinburgh-London: E. & S. Livingstone Ltd. 1969.

    Google Scholar 

  • Ozolins, A., Lineberger, W. C., Niles, F. E.: Temperature effect on spectrometer slit width and photomultiplier sensitivity. Rev. sci. Instr. 39, 1039–1043 (1968).

    Google Scholar 

  • Pital, A., Janowitz, S. L.: Enhancement of staining intensity in the fluorescent-antibody reaction. J. Bact. 86, 888–889 (1963).

    Google Scholar 

  • Ploem, J. S.: The use of a vertical illuminator with interchangeable dichroic mirrors for fluorescence microscopy with incident light. Z. wiss. Mikr. 68, 129–142 (1967).

    Google Scholar 

  • — Ein neuer Illuminator-type für die Auflichtfluoreszenzmikroskopie. Leitz-Mitt. Wiss. u. Techn. 6, 225–238 (1969).

    Google Scholar 

  • — Standards for fluorescence microscopy. In: Standardization in immunofluorescence, ed. by E. J. Holborow, p. 137–153. Oxford-Edinburgh: Blackwell Scientific Publications 1970.

    Google Scholar 

  • Rigler, R. Jr.: Microfluorometric characterization of intracellular nucleic acids and nucleoproteins by acridine orange. Acta physiol. scand. 67, Suppl. 267 (1966).

  • Rotman, B.: Measurement of activity of single molecules of β-D-galactosidase. Proc. nat. Acad. Sci. (Wash.) 47, 1981–1991 (1961).

    Google Scholar 

  • Ruch, F.: Principles and some applications of cytofluorometry. In: Introduction to quantitative cytochemistry —II, ed. by G. L. Wied and G. F. Bahr, p. 431–450. New York-London: Academic Press 1970.

    Google Scholar 

  • Sernetz, M., Thaer, A.: A capillary fluorescence standard for microfluorometry. J. Micr. 91, 43–52 (1970).

    Google Scholar 

  • Thaer, A. A.: Instrumentation for microfluorometry. In: Introduction to quantitative cytochemistry, ed. by G. L. Wied, p. 409–426. New York: Academic Press 1966.

    Google Scholar 

  • Udenfried, S.: Fluorescence assay in biology and medicine. New York-London: Academic Press 1962.

    Google Scholar 

  • Young, M. R.: Excitation techniques and standardization in immunofluorescence. In: Standardization in immunofluorescence, ed. by E. J. Holborow, p. 105–112. Oxford-Edinburgh: Blackwell Scientific Publications 1970.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

From the Study Group on Quantitative Immunofluorescence.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jongsma, A.P.M., Hijmans, W. & Ploem, J.S. Quantitative immunofluorescence. Histochemie 25, 329–343 (1971). https://doi.org/10.1007/BF00278226

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00278226

Keywords

Navigation