Le risque de non-consolidation après enclouage à foyer fermé et alésage

Résultats de 1059 interventions selon G. Kuntscher

The incidence of non-union in closed intramedullary nailing

  • Published:
International Orthopaedics Aims and scope Submit manuscript

Summary

The authors have studied a series of 1059 compound and closed fractures of the diaphysis of long bones treated by intramedullary nailing occording to the technique of Kuntscher, to assess the incidence of non-union. Between January 1st 1967 and December 31st 1980, 503 fractures of the tibia, 440 of the femur and 116 of the humerus were so treated in both adolescents and adults. The fractures were mostly sustained in road traffic accidents. The risk of aseptic non-union was small, but occured more readily when the skin was damaged and when the site of the fracture was at the junction of the lower two quarters of the tibia; the incidence was highest when the technique of nailing was incorrect or when the going was undertaken too late. The incidence of non-union and infection are compared with those of other series using the same closed technique and with reports describing insertion of the nail of the plate by opening the fracture. It is concluded that intramedullary nailing using the Kuntscher technique is the most reliable treatment for this type of injury for routine use in an acute fracture service. In this series the incidence of aseptic non-union was approximately 1%, of infection with non-union less than 0.5% and of early infection with eventual union less than 1.5%.

Résumé

Les auteurs étudient sur le plan du risque de la non-consolidation une série continue de 1059 enclouages selon Kuntscher pour fractures diaphysaires fermées et ouvertes de 503 tibias, 440 fémurs et 116 humérus réalisés entre le ler janvier 1967 et le 31 décembre 1980 chez des adolescents et des adultes victimes pour la plupart d'accidents de la voie publique. Ils montrent que le taux de pseudarthroses aseptiques y est faible, essentiellement lié à des facteurs contingents telle que l'ouverture cutanée, à des facteurs favorisants de nature topographique et à des facteurs déterminants avant tout représentés par des défauts techniques d'enclouage et par la remise en charge trop tardive. Ils comparent leurs résultats avec ceux d'autres séries utilisant la même technique et avec ceux de séries qui recourent au foyer ouvert et, se plaçant sur le plan général des risques de la non-consolidation et du sepsis, ils concluent que l'enclouage selon Kuntscher représente la méthode la plus fiable de traitement de routine dans un service formateur, des fractures diaphysaires ouvertes et fermées du tibia, du fémur et de l'humérus. Dans leur expérience, le risque de non-consolidation aseptique oscille autour de 1%, celui de non-consolidation septique est inférieur à 0,5% et celui du sepsis précoce avec consolidation inférieur à 1,5%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Réferences

  1. Babin, S. R.: Les fractures de la diaphyse humérale de l'adulte. Cahiers d'enseignement de la S. O. F. C. O. T., Conférences d'enseignement. Expansion Scientifique Fraçaise, 91–114 (1978)

  2. Babin, S. R., Graf, P., North, H., Schvingt, E.: Complications septiques des ostéosynthèses à foyer fermé. Journée de Printemps de la S. O. F. C. O. T., Strasbourg, 28 mai 1981 Résumé in Rev. Chir. Orthop. 67 635–36 (1981)

    Google Scholar 

  3. Babin, S. R., Graf, P., North, J., Schvingt, E.: Le risque septique de l'ostéosynthèse à foyer fermé d'après une série continue de 1059 enclouages selon G. Kuntscher. Int. Orthop. 5 271–276 (1981)

    Google Scholar 

  4. Benoit, J., Cirotteau, Y., Huard, C., Tomeno, B.: Etude critique des échecs dans le traitement des fractures fraiches de la diaphyse fémorale. A propos de 330 cas. Rev. Chir. Orthop. 60 445–483 (1974)

    Google Scholar 

  5. Bezes, H. et Julliard, R. avec la collaboration de Bocchio J. J., Autones, M., Saucier, Th., Banon, F.: Les accidents du ski. A propos d'une statistique de 5200 observations. Ann. Chir. 30 (8), 583–605 (1976)

    Google Scholar 

  6. Bombart, M., Decoulx, J., Dubousset, J., Kempf, I., Zucman, J.: Forum de l'enclouage à foyer fermé des diaphyses tibiales et fémorales. Rev. Chir. Orthop. 56 775–786 (1970)

    Google Scholar 

  7. Brunet, J. C., Patel, A.: Ostéosynthèses diaphysaires jambe. 547 cas. Actualités de Chirurgie Orthopédique de l'Hôpital Raymond Poincaré Masson Edit., VIII, 42–50 (1970)

    Google Scholar 

  8. Decoulx, J., Carlier, Y., Capron, J. C., Bouretz, J. C.: Les fractures polyfragmentaires de la diaphyse fémorale (78 cas). Lille Chir. 29 3–10 (1974)

    Google Scholar 

  9. Decoulx, J., Kempf, I., Jenny, G., Schvingt, E., Petit, P., Vives, P.: Enclouage à foyer fermé avec alésage du fémur selon Kuntscher. Technique, indications et résultats à propos de 399 cas. Rev. Clm. Orthop. 61 465–486 (1975)

    Google Scholar 

  10. Evrard, J., Lebard, J. P., Tomeno, B.: Le risque septique dans les fractures récentes des la diaphyse fémorale (460 fractures fraîches). Rev. Chir. Orthop. 60 25–37 (1974)

    Google Scholar 

  11. Jacquemaire, B.: L'enclouage d'alignement des fractures diaphysaires du fémur. Application originale de la méthode de Kuntscher. A propos de 41 cas. Thèse Strasbourg, 1974, no 173 (Président: E. Schvingt).

  12. Lignac, F., Brumpt, B.: Etude et résultats de 255 fractures de la diaphyse fémorale. Actualités de Chirurgie Orthopédique de l'Hôpital Raymond Poincaré. Masson Edit., XII, 64–91 (1975)

    Google Scholar 

  13. Masse, Y., Aubriot, J. H., Lamotte N.: Fractures diaphysaires de jambe traitées par enclouage à foyer fermé sans alésage. Etude d'une série de 521 cas. Rev. Chir. Orthop. 63 575–591 (1977)

    Google Scholar 

  14. Panda, M., Burny F.: Traitement des fractures sous-trochantériennes et trochantérodiaphysaires. Acta Orthop. Belg. 42 429–444 (1976)

    Google Scholar 

  15. Ruedi, Th., Leutenegger, A.: Die Osteosynthesen der subtrochanteren Femurfrakturen. Unfallheikunde, 80 183–186 (1977)

    Google Scholar 

  16. Saragaglia, D.: De l'utilisation éclectique des clous et des plaques vissées dans les ostéosynthèses de la diaphyse fémorale. (420 ostéosynthèses: 110 clous, 310 plaques; 1968–1797.) Thèse Grenoble, 1980 (Service H. Bezes).

  17. Schvingt, E.: Fractures complexes et fracas diaphysaires fémoraux, traitement par enclouage d'alignement à foyer fermé (62 cas). Chirurgie 101 901–908 (1975)

    Google Scholar 

  18. Schvingt, E., Jacquemaire, B., Babin, S., Katzner, M.: L'enclouage d'alignement des fractures diaphysaires du fémur. Application originale de la méthode de Kuntscher. A propos de 44 cas. Rev. Chir. Orthop. 62 137–149 (1976)

    Google Scholar 

  19. Simon, P.: L'enclouage d'alignement des fractures du tibia; étude d'une série de 144 cas. Thèse Strasbourg, 1979, no 108 (Président E. Schvingt).

  20. Taillard W., Papadimitriou G., Bagnoud F., Tschanz P.: L'ostéosynthèse différée des fractures diaphysaires du fémur chez l'adulte. Rev. Chir. Orthop. 62 309–320 (1976)

    Google Scholar 

  21. Vives, P., Massy, E., Dubois, P., Decoopmann, P.: Faut-il choisir le clou ou la plaque pour traiter une fracture de jambe? Rev. Chir. Orthop. 61 693–703 (1975)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Babin, S.R., Graf, P., Vidal, P. et al. Le risque de non-consolidation après enclouage à foyer fermé et alésage. International Orthopaedics 7, 133–143 (1983). https://doi.org/10.1007/BF00266462

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00266462

Key words