Summary
In order to improve dog kidney perfusion in situ with a protective solution, a perfusion catheter was constructed which allowed continuous pressure measurement in the center of the catheter tip during perfusion. Using this catheter, the equilibration of the extracellular space with a protective solution (HTK solution) was found to be pressure dependent. Continuous pressure and resistance control is therefore a prerequisite for reliable organ protection.
Similar content being viewed by others
References
Bretschneider HJ (1961) Methoden zur Messung der Durchblutung mit einem hohen zeitlichen Auflösungsvermögen. In: Kraus H, Klepzig H (eds) Kreislaufmessungen. Werk-Verlag Dr. E. Banaschewski, München-Gräfelfing, pp 157–174
Eck B (1961) Technische Strömungslehre. Sechste Auflage. Springer, Berlin Göttingen Heidelberg
Hirokawa W (1908) Über den osmotischen Druck des Nierenparenchyms. Hofmeisters Beitr Physiol Pathol 11:458–478
Hölscher M (1982) Verbesserung der Nierenprotektion zur Verlängerung der Ischämietoleranz bei in situ Operationen und bei Transplantationen. Habilitationsschrift, München
Kallerhoff M, Hölscher M, Kläß G, Bretschneider HJ (1980) The equilibration proceedings at a 12' long perfusion of kidneys with HTP-solution of Bretschneider. Pflügers Arch 389 (Suppl):R43
Kehrer G, Gebhard MM, Kallerhoff M, Siekmann W, Blech M, Helmchen U, Bretschneider HJ (1984) The influence of glucose premedication on perfusion resistance, perfusional diuresis and equilibration of the dog kidney during perfusion with Bretschneider's cardioplegic solution “HTK” in standardized anaesthesia. Pflügers Arch 400 (Suppl):R22
Marberger M (1983) In situ cooling of the kidney. In: Marberger M, Dreikorn K (eds) Renal preservation. Williams and Wilkins, Baltimore London, pp 38–63
Rosetti SR (1983) Impact of acute ischemia on human kidney. In: Marberger M, Dreikorn K (eds) Renal preservation. Williams and Wilkins, Baltimore London, pp 21–37
Thurau K, Deetjen P (1962) Die Diurese bei arteriellen Drucksteigerungen. Die Bedeutung der Hämodynamik des Nierenmarks für die Harnkonzentrierung. Pflügers Arch 274:567–580
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Kehrer, G., Kallerhoff, M., Probst, R. et al. Construction and experimental application of a catheter for selective arterial kidney perfusion in situ. Urol. Res. 13, 85–89 (1985). https://doi.org/10.1007/BF00261572
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00261572