Skip to main content
Log in

Construction and experimental application of a catheter for selective arterial kidney perfusion in situ

  • Originals
  • Published:
Urological Research Aims and scope Submit manuscript

Summary

In order to improve dog kidney perfusion in situ with a protective solution, a perfusion catheter was constructed which allowed continuous pressure measurement in the center of the catheter tip during perfusion. Using this catheter, the equilibration of the extracellular space with a protective solution (HTK solution) was found to be pressure dependent. Continuous pressure and resistance control is therefore a prerequisite for reliable organ protection.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bretschneider HJ (1961) Methoden zur Messung der Durchblutung mit einem hohen zeitlichen Auflösungsvermögen. In: Kraus H, Klepzig H (eds) Kreislaufmessungen. Werk-Verlag Dr. E. Banaschewski, München-Gräfelfing, pp 157–174

    Google Scholar 

  2. Eck B (1961) Technische Strömungslehre. Sechste Auflage. Springer, Berlin Göttingen Heidelberg

    Google Scholar 

  3. Hirokawa W (1908) Über den osmotischen Druck des Nierenparenchyms. Hofmeisters Beitr Physiol Pathol 11:458–478

    Google Scholar 

  4. Hölscher M (1982) Verbesserung der Nierenprotektion zur Verlängerung der Ischämietoleranz bei in situ Operationen und bei Transplantationen. Habilitationsschrift, München

  5. Kallerhoff M, Hölscher M, Kläß G, Bretschneider HJ (1980) The equilibration proceedings at a 12' long perfusion of kidneys with HTP-solution of Bretschneider. Pflügers Arch 389 (Suppl):R43

  6. Kehrer G, Gebhard MM, Kallerhoff M, Siekmann W, Blech M, Helmchen U, Bretschneider HJ (1984) The influence of glucose premedication on perfusion resistance, perfusional diuresis and equilibration of the dog kidney during perfusion with Bretschneider's cardioplegic solution “HTK” in standardized anaesthesia. Pflügers Arch 400 (Suppl):R22

  7. Marberger M (1983) In situ cooling of the kidney. In: Marberger M, Dreikorn K (eds) Renal preservation. Williams and Wilkins, Baltimore London, pp 38–63

    Google Scholar 

  8. Rosetti SR (1983) Impact of acute ischemia on human kidney. In: Marberger M, Dreikorn K (eds) Renal preservation. Williams and Wilkins, Baltimore London, pp 21–37

    Google Scholar 

  9. Thurau K, Deetjen P (1962) Die Diurese bei arteriellen Drucksteigerungen. Die Bedeutung der Hämodynamik des Nierenmarks für die Harnkonzentrierung. Pflügers Arch 274:567–580

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kehrer, G., Kallerhoff, M., Probst, R. et al. Construction and experimental application of a catheter for selective arterial kidney perfusion in situ. Urol. Res. 13, 85–89 (1985). https://doi.org/10.1007/BF00261572

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00261572

Key words

Navigation