Skip to main content

Value of additional lateral scans in renal scintigraphy

Abstract

Although it is common to perform scintigrams in multiple projections this technique has not yet been generally accepted for kidney scintigraphy.

By performing additional lateral scans using an Anger camera and with patients sitting we found at least three advantages:

  1. 1.

    Better Visualisation of Kidney Lesions: 7 (13,5%) of 52 cases with lesions could be detected in lateral projection only, in all other cases we obtained better information concerning location and size of lesions.

  2. 2.

    Determination of Real Kidney Size: Of 62 patients with kidneys appearing reduced unilaterally in the dorsal projection, additional lateral recordings demonstrated that 24 (39%) seemed diminished because of tilting.

  3. 3.

    Better Interpretation of Renograms: Demonstration of different depths of kidneys facilitates interpretation of renograms with different peak heights. Additional lateral scans thus can provide — at least if dorsal recordings are inconclusive — further information.

This is a preview of subscription content, access via your institution.

References

  • Breuel, H.P., Kraft, W., Bähre, M., Emrich, D.: Das seitliche Nierenszintigramm. Fortschr. Röntgenstr. 125, 48 (1976)

    Google Scholar 

  • Chervu, L.R., Freeman, L.M., Blaufox, M.D.: Radiopharmaceuticals for renal studies. Sem. Nucl. Med. 4, 3 (1974)

    Google Scholar 

  • Enlander, D., Weber, P.M., dos Remedios, L.V.: Renal cortical imaging in 35 patients: superior quality with 99m Tc DMSA. J. Nucl. Med. 15, 743 (1974)

    Google Scholar 

  • Feine, U., zum Winkel, K.: Nuklearmedizin, Szintigraphische Diagnostik. Stuttgart: Thieme 1969

    Google Scholar 

  • Köhn, H., Mostbeck, A.: Verbesserung der nierenszintigraphischen Aussage-Größe, Parenchymausfall-durch seitliche Aufnahme. Mitt. Österr. Nukl. med. Ges., Nr. 13, Nov. (1975)

  • Mostbeck, A.: Quantitative Funktionsprüfung der Nieren auf Basis der Tiefenkorrektur und der frühen Hippuranakkumulation. Nuklearmedizin, 13. Int. Jahrestagung d. Ges. f. Nuk. med. Kopenhagen, 10–13. Sept. 1975. Stuttgart: Schattauer 1977

    Google Scholar 

Download references

Author information

Affiliations

Authors

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Köhn, H.D., Mostbeck, A. Value of additional lateral scans in renal scintigraphy. Eur J Nucl Med 4, 21–25 (1979). https://doi.org/10.1007/BF00257565

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00257565

Keywords

  • Public Health
  • Nuclear Medicine
  • Peak Height
  • Good Information
  • Lateral Projection